CONFIDENTIAL
Z3-DM368-ZDVR V1.03.01
___________________________________________________________________________________________
Z3 Technology, LLC
♦
100 N 8
th
ST, STE 250
♦
Lincoln, NE 68508-1369 USA
♦
+1.402.323.0702
13
5.3 Set up the Terminal Window
(5) If you are running from a Windows PC, run TeraTerm. Select
“Setup – Serial Port” and set the
following:
Port:
Whichever serial port the port is connected to
Baud Rate: 115200
Data:
8-bit
Parity:
None
Stop:
1-bit
Flow Control: None
(6) If you are running from Linux, type:
# sudo minicom –s
And then configure by doing the following:
-Select “Serial Port Setup”
-Ensure the right Serial Device is specified (typically “/dev/ttyUSB0”)
-Set option E (“Bps/Par/Bits”) to 115200 8N1
-Press <return>
-Select “Exit”
5.4 Power on the board
(7) Connect the 5V power supply and turn on the switch. If all is configured properly, you should see the
board booting up within the terminal window. After about a minute, you will see the app load up and
the words “Preloading gstreamer components” – once you see that, the ZDVR app is ready to go.
Figure 6 ZDVR Startup Message