A.1.1 Exclusion Zone
It is recommended that you allow for an “exclusion zone” of 0.25" (6 mm) around the
BL2600 in all directions when the BL2600 is incorporated into an assembly that includes
other components. This “exclusion zone” that you keep free of other components and
boards will allow for sufficient air flow, and will help to minimize any electrical or EMI
interference between adjacent boards. An “exclusion zone” of 0.12" (3 mm) is recom-
mended below the BL2600. Figure A-2 shows this “exclusion zone.”
Figure A-2. BL2600 “Exclusion Zone”
Real-Time Clock
Yes
Timers
Ten 8-bit timers (6 cascadable, 3 reserved for internal peripherals),
one 10-bit timer with 2 match registers
Watchdog/Supervisor
Yes
Power
9–36 V DC, 12 W max.
Operating Temperature
–40°C to +70°C
(–40°C to +85°C without battery)
Humidity
5–95%, noncondensing
Board Size
4.85" × 4.96" × 1.00"
(123 mm × 126 mm × 25 mm)
* 256K flash/128K SRAM options available options available for BL2610.
Table A-1. BL2600 Specifications (continued)