16
Wolf (BL2600)
3.2.3 High-Current Digital Outputs
The BL2600 has four high-current digital outputs, HOUT0–HOUT3, which can each sink
or source up to 2 A. Figure 9 shows a wiring diagram for using the digital outputs in either
a sinking or a souring configuration.
Figure 9. BL2600 High-Current Digital Outputs
All the digital outputs sink and source actively. They can be used as high-side drivers, low-
side drivers, or as an H-bridge driver. When the BL2600 is first powered up or reset, all
the outputs are disabled, that is, at a high-impedance tristate, until the
digHoutConfig
software function call is made. The
digHoutConfig
call sets the initial state of each
high-current output according to the configuration specified by the user, and enables the
digital outputs to their initial status.
Table 4. BL2600 High-Current Outputs Logic States
U3 Output
High-Current Output
A
B
High
High
Prohibited
(defaults to sourcing)
High
Low
Sourcing
Low
High
Sinking
Low
Low
High-impedance (tristate)
+HK
x
100 k
W
330
W
10 k
W
10 k
W
27 k
W
1 nF
100 k
W
1 nF
MMBT4401
B
A
(in
sinking
mode)
(in