User’s Manual
49
4.4.3 Serial Communication
Library files included with Dynamic C provide a full range of serial communications sup-
port. The
RS232.LIB
library provides a set of circular-buffer-based serial functions. The
PACKET.LIB
library provides packet-based serial functions where packets can be delim-
ited by the 9th bit, by transmission gaps, or with user-defined special characters. Both
libraries provide blocking functions, which do not return until they are finished transmit-
ting or receiving, and nonblocking functions, which must be called repeatedly until they
are finished. For more information, see the
Dynamic C User’s Manual
and Technical Note
213,
Rabbit 2000 Serial Port Software
.
Use the following function calls with the BL2600.
User interface to set up BL2600 serial communication lines. Call this function after
serXOpen()
.
Whether you are opening one or multiple serial ports, this function must be executed after executing the
last
serXOpen
function AND before you start using any of the serial ports. This function is non-reentrant.
If Mode 1 is selected, CTS/RTS flow control is exercised using the
serCflowcontrolOn
and
serCflowcontrolOff
functions from the
RS232.LIB
library.
PARAMETER
mode
is the defined serial port configuration.
RETURN VALUE
0 if valid mode selected, 1 if not.
SEE ALSO
brdInit, ser485Tx, ser485Rx
int serMode(int mode);
Mode
Serial Port
C
F
E
0
RS-232, 3-wire
RS-232, 3-wire
RS-232, 3-wire
1
RS-232, 3-wire
RS-232, 3-wire
RS-485
2
RS-232, 5-wire
RTS/CTS
RS-232, 3-wire
3
RS-232, 5-wire
RTS/CTS
RS-485
Содержание Wolf BL2600
Страница 1: ...Wolf BL2600 C Programmable Single Board Computer with Ethernet User s Manual 019 0142 040731 B ...
Страница 36: ...32 Wolf BL2600 ...
Страница 66: ...62 Wolf BL2600 ...
Страница 100: ...96 Wolf BL2600 ...
Страница 104: ...100 Wolf BL2600 ...
Страница 106: ......