User’s Manual
17
Each high-current output has its own +K supply. When wiring the high-current outputs,
keep the distance to the power supply as short as possible.
CAUTION:
If you are using a BL2600 with the IDC header connectors, beware that
an individual IDC header pin can only handle up to 1 A. Since the same high-current
outputs are available on opposite pairs of IDC header connectors, you can still use the
2 A sinking or sourcing capability of the BL2600 by wiring all your connections,
including the ground, in parallel to the opposite pairs (see Figure 10 for an example).
Figure 10. Example of Wiring HK0 In Parallel on IDC Header
For the H bridge, which is shown in Figure 11, Ka and Kb
should be the same
.
Figure 11. H Bridge
J13
GND
+HK0
HOUT0
GND
+HK1
HOUT1
GND
+HK2
HOUT2
GND
+HK3
HOUT3
GND
0 1 2 3
GND
+HK0
HOUT0
GND
+HK1
HOUT1
GND
+HK2
HOUT2
GND
+HK3
HOUT3
GND
+HK0
+Ka
+Kb
LOAD