background image

 

 

13 

 

 

 

 

 

 

Select 

Delete 

Device

.  

 

 

 

 

 

 

Press 

 key to delete 

the device from Z-Wave 
network. 

 

 

 

 

 

 

Press the program button 
on the target device. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1: If no ACK signal received for more than 60 seconds, the 
“Delete Device” mode will exit automatically. 

 

Note 2: In a Z-Wave network, only the primary controller or inclusion 
controller can delete or exclude devices into its network. If ZRC-100 is 
configured as a secondary controller, it will report “Error” if users 
attempt to use ZRC-100 to delete a device from its network. 

 
 

Setup 

Add Device

Delete Device 

>

 

Add to Scene 

>

 

OK to Enter

 

Delete Device 

Press PROG on target

 

>>>>

 

Saving Data … 

Delete Device 

Press PROG on target

 

>>>>

 

OK 

Delete Device 

Press PROG on target

 

>>>>

 

Setup 

Add Device

Delete Device 

>

 

Add to Scene 

>

 

OK to Enter

 

Содержание ZRC-100

Страница 1: ...1 ZRC 100 Z Wave Remote Controller...

Страница 2: ...Comfort Sensor Configure 25 Shortcut Key 27 Z Wave Advanced Setup 29 Learning Mode 29 Configure Association 31 Change Device Configuration 37 Resetting Your Network 39 System Settings 40 About ZRC 10...

Страница 3: ...3 TECHNICAL SPECIFICATIONS 55 CHECKING THE ACCESSORIES 56 FCC NOTICE 56 WARNINGS 56 CAUTION 57...

Страница 4: ...y Z Wave enabled devices binary switches dimmers thermostats secured door locks binary or multi level sensors Users can control their Z Wave enabled devices individually or through Scene control Scene...

Страница 5: ...r can be used to include or delete modules from a network It is recommended that you mark the primary controller for each network for ease in modifying your network Secondary Controller A controller c...

Страница 6: ...ease carefully read through the following sections of this user manual and store for future reference Before using the ZRC 100 please install the batteries 4xAAA batteries are required for operation R...

Страница 7: ...on Keys Keys Functions Short cut keys for 1 Device and scene control 2 Short cut to user selected control menu Back to previous screen 4 way directional keys for setup and control OK key for confirmat...

Страница 8: ...rt A4 Sensor A5 All Off A6 Devices List A2 1 Scenes List A3 1 Comforts List A4 1 Sensors List A5 1 or Press c ord keys to select control category Press BACK key to go back to previous page Press and h...

Страница 9: ...9 1 Shortcut Key B10 1 Learning Mode B11 1 Select Scene B5 1 Scene Configure B7 1 Comfort Configure B8 1 Config Assoc B11 2 Configuration B11 3 Reset to Default B11 4 LCD Contrast B12 1 B L Brightness...

Страница 10: ...of controllable End point EP device sensor 128 items listed on the Device and Sensor page Total number of thermostats 6 thermostats listed on the Comfort page Total number of scenes 12 scenes listed...

Страница 11: ...nds to go back to the root menu at any setup operation screen Add Delete Devices Adding Device to the Network Step Setup Key LCD Indication 1 Press and hold ef keys simultaneously for 3 seconds under...

Страница 12: ...work only the primary controller or inclusion controller can add or include devices into its network If ZRC 100 is configured as a secondary controller it will report Error if users attempt to use ZRC...

Страница 13: ...he primary controller or inclusion controller can delete or exclude devices into its network If ZRC 100 is configured as a secondary controller it will report Error if users attempt to use ZRC 100 to...

Страница 14: ...off the device 3 To operate dimmer and motorized curtain Press and hold the f key until reach to your desired level and release the key to open the curtain or to increase the dimmer intensity Press a...

Страница 15: ...ontroller timed event or specific conditions For example a user prefers to set the dimmer to a low intensity level and close the motorized curtain when he watch movie He can define a scene to control...

Страница 16: ...5 Adjust the target device on off or dim level with its program button to the desired level Setup Add Device Delete Device Add to Scene OK to Enter Setup Add Device Delete Device Add to Scene OK to E...

Страница 17: ...y LCD Indication 1 Press and hold ef keys simultaneously for 3 seconds under the Home page 2 Select Remove from Scene and press key 3 Select a Scene which you want to delete the device from Scene and...

Страница 18: ...s done you can trigger the desired scene via scene control function on ZRC 100 Step Setup Key LCD Indication 1 Select Scene and press key to confirm A corresponding Scene Control page will be displaye...

Страница 19: ...and press key to confirm A corresponding Comfort Control page will be displayed 2 Select your Thermostat and press key to entry the Thermostat control page 3 Use ef keys to switch the operation mode s...

Страница 20: ...A corresponding Sensor page will be displayed Device Configure It is allow to Move Rename Delete the device after added into the network under the Device Configure function Step Setup Key LCD Indicat...

Страница 21: ...target position and press to save the setting 6 Select your action e g Rename and press key Setup Remove fr Scene Device Config Scene Config OK to Enter Device Configure Dimmer 002 Dimmer 004 OK to E...

Страница 22: ...e selected device or Press e key to cancel it and go back to previous page Note 1 ZRC 100 supports up to 16 characters in a row for the device name Note 2 This process will only remove the devices EPs...

Страница 23: ...for 3 seconds under the Home page 2 Select Scene Configure and press key 3 Select your Scene and press key 4 Select your action e g Move and press key Home Device Scene Comfort OK to Enter Setup Add D...

Страница 24: ...change your character and ef keys to select character position press to save the setting 8 Select your action e g Clear and press key Move Scene 1 Scene 2 Scene 3 OK to Save Edit Move Rename Clear OK...

Страница 25: ...emote controller and the Scene information mapping from gateway primary controller is unsuccessful Comfort Sensor Configure It is allow to Move Rename Delete the device after added into the network un...

Страница 26: ...tion e g Rename and press key 7 Use cdkeys to change your character and ef keys to select character position press to save the setting Comfort configure Thermostat003 OK to Enter Edit Move Rename Dele...

Страница 27: ...nly remove the devices EPs from its catalogue but will not exclude it from the network Shortcut key ZRC 100 provides a shortcut key which can jump to your target Comfort Sensor device or turn On Off y...

Страница 28: ...key then press key 6 Press key to turn On your Device or Scene at any page or Press and hold key to turn Off your Device or Scene at any page Press your shortcut key can jump to your target Comfort Se...

Страница 29: ...e Z Wave network Step Setup Key LCD Indication 1 Place the two controllers close to each other 2 Press and hold ef keys simultaneously for 3 seconds under the Home page 3 Select Advanced Setup and pre...

Страница 30: ...ne Controller Configuration Command and Association Command If scenes are copied to a secondary controller using the replication function those scenes cannot be modified using the Scene Controller Con...

Страница 31: ...n Association Group Step Setup Key LCD Indication 1 Press and hold ef keys simultaneously for 3 seconds under the Home page 2 Select Advanced Setup and press key 3 Select Config Assoc and press key 4...

Страница 32: ...ight switch 7 Press the program EP button on the primary device e g door sensor It will turn on the light switch when the door is open Add Assoc Assoc ID 1 255 000 OK to Save Add Assoc Assoc ID 1 255...

Страница 33: ...keys simultaneously for 3 seconds under the Home page 2 Select Advanced Setup and press key 3 Select Config Assoc and press key 4 Select Remove Assoc and press key Home Device Scene Comfort OK to Ent...

Страница 34: ...ndary device e g light switch 7 Press the program EP button on the primary device e g door sensor Remove Assoc Assoc ID 1 255 000 OK to Save Remove Assoc Assoc ID 1 255 001 OK to Save Remove Assoc Pre...

Страница 35: ...neously for 3 seconds under the Home page 2 Select Advanced Setup and press key 3 Select Config Assoc and press key 4 Select Delete Assoc and press key Home Device Scene Comfort OK to Enter Setup Add...

Страница 36: ...utton on the primary device e g door sensor Note 1 This process will only remove the group devices EPs from its assigned association group but will not exclude it from the network Delete Assoc Assoc I...

Страница 37: ...d ef keys simultaneously for 3 seconds under the Home page 2 Select Advanced Setup and press key 3 Select Configuration and press key 4 Use cdkeys to change your parameter number and ef keys to select...

Страница 38: ...mber position press to save the setting Parameter value from 2147483648 to 2147483647 32bits value 6 Press the program button on the target device Configuration Parameter Value 0000000000 OK to Save C...

Страница 39: ...nced Setup and press key 3 Select Reset to Default and press key 4 Press f key to confirm to reset to factory default or Press e key to cancel it and go back to previous page Home Device Scene Comfort...

Страница 40: ...s Step Setup Key LCD Indication 1 Press and hold ef keys simultaneously for 3 seconds under the Home page 2 Select System Settings and press key Home Device Scene Comfort OK to Enter Setup Add Device...

Страница 41: ...age then select Sleep Timer and press key 8 Press ef keys to adjust the sleep timer Note 1 The batteries service life will be shortened if the sleep timer set to higher value System Settings LCD Contr...

Страница 42: ...econds under the Home page 2 Select About and press key It will show the firmware version on the screen Home Device Scene Comfort OK to Enter Setup Add Device Delete Device Add to Scene OK to Enter Se...

Страница 43: ...p Key LCD Indication 1 Press and hold cb keys simultaneously for 3 seconds under the Home page 2 Select Rediscover N W and press key 3 The remote is updating the network information The LCD will displ...

Страница 44: ...Sensors and names will be re assigned with default naming in ascending order which is implemented by the function of Re scan Devices To implement this function your ZRC 100 is needed to follow below s...

Страница 45: ...LCD will display OK and go back to previous page when it is completed This action may take up to 0 5 1 hour depends on how many devices are in your network and it will wipe out all previously stored...

Страница 46: ...key 3 The remote is checking the dead node The LCD will display OK and go back to previous page when it is completed Home Device Scene Comfort OK to Enter Network Setup Rediscover N W Delete Dead Node...

Страница 47: ...he Z Wave protocol version and the supported Z Wave command version of this controller Manufacturer command class To get the manufacture ID product type ID and the product ID of this controller Scene...

Страница 48: ...a Secondary Controller Copying Network Information to a Secondary Controller You can add a secondary controller to your network and copy all of your primary controller s network information to the sec...

Страница 49: ...after this action Original ZRC 100 primary controller will still keep in a primary controller after this action Create a Primary Controller Transferring Only Network Information to a New Primary Cont...

Страница 50: ...y the Learning mode if this is a another ZRC 100 Please refer to the target controller user manual for more information Target primary controller will act as a primary controller after this action Ori...

Страница 51: ...d reduce the range by up to 25 to 30 MAINTENANCE 1 Do not expose your remote to dust strong sunlight humidity high temperatures or mechanical shocks 2 Do not use old and new batteries together as old...

Страница 52: ...what should I do for my ZRC 100 How to copy my scenes settings to my ZRC 100 A Your ZRC 100 can act as a secondary controller with network information about other devices and scenes setting acquired...

Страница 53: ...1 hour depends on how many devices are in your network and it will wipe out all previously stored device names Please make sure batteries are full before proceed iv Now all Z Wave devices will appear...

Страница 54: ...ve setup information from your primary remote onto a new secondary remote Q Where can I keep up to date with the latest Z Wave products for my house A You can keep up to date by visiting the www remot...

Страница 55: ...t Power Dry cell AAA x 4pcs Temperature operation 0 40 storage 20 60 Dimension LxWxT 161mm x 52mm x 15mm Weight 75g Batteries excluded Z Wave device type Basic Device Class BASIC_TYPE_CONTROLLER Gener...

Страница 56: ...d operation WARNINGS Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment RISK OF FIRE RISK OF ELECTRICAL SH...

Страница 57: ...in a hazardous condition For these reasons we recommend the following z Do not include Z Wave devices to control electric heaters or other appliances which may present a hazardous condition due to an...