background image

 

1

ST814 

Temperature/Humidity Detector 

 
The Temperature/Humidity Detector is a Z-Wave

TM

 enabled device which is fully 

compatible with any Z-Wave

TM

 enabled network.  Z-Wave

TM

 enabled devices 

displaying the Z-Wave

TM

 logo can also be used with it regardless of the 

manufacturer, and ours can also be used in other manufacturer’s Z-Wave

TM

 

enabled networks.    Inclusion of this detector on other manufacturer’s Wireless 
Controller menu allows remote operation of connected modules when the 
detector is triggered. 
 
The Temperature/Humidity Detector is designed to monitor the current 
temperature and humidity of ambient environment. The reading of 
temperature/humidity can be reported to you on a regular base at your disposal.   
If temperature/humidity reaches set points, the detector will send alerts to 
associated devices for further execution. Since sudden temperature/humidity 
change may cause health problems to people such as elderly or very young 
children, Temp./Humid. Detector provides you most up-to-date temperature and 
humidity reading for you to watch your family’s health. 
   

 

Product Overview 
 

 

 

 

 

 

 

 

 
 
 
 
 
 

 
 

1

 

LCD Screen 

2

 

Function Keys

 

 

Select modes/Change setting

 

 

Select temperature unit/Linking

 

MAX

/▲

 

Increase settings, displays max. temperature/humidity or 
enable RF & beep tone

 

MIN/

 

Decrease settings, displays min. temperature/humidity or 
disable RF & beep tone 

3

 

Temperature/Humidity Sensor

 

4

 

Mounting Bracket

 

 

LCD Display 

 
 
 
 
 
 
 
 
 
 
 
Include to or Exclude from a Z-Wave

TM

 Network 

 
One of function key (

) is used to carry out inclusion, exclusion, association 

and reset.    When the detector is first powered up, the reading in RF mode is 00 
which implies that it hasn’t been allocated a node ID and cannot work with 
Z-Wave

TM

 enabled devices.    The Temp./Humid. Detector will stay “awake” for 

10 minutes when power is first applied to allow time for configuration.    Please 
get familiar with the terms below before starting the operations.     

 

Function

 

Description

 

Inclusion 

 

Add a Z-Wave enabled device (e.g.Temp./Humid Detector) to Z-Wave 
network.

 

Exclusion 

 

Delete a Z-Wave enabled device (e.g. Temp./Humid Detector) from the 
network.

 

Association 

After inclusion, you have to define the relationship between devices. 
Trough association, device can be assigned as master/slave, and 
specify which slave is going to be controlled by which master.

 

Reset

 

Restore Temp./Humid Detector to factory default.

 

 
The table below lists an operation summary of basic Z-Wave functions.    Please 
refer to the instructions for your Z-Wave

TM

 Certificated Primary Controller to 

access the setup function, and to include/exclude/associate devices. 
 

Function Description 

LED 

Indication 

No node 
ID 

The Z-Wave Controller does not 
allocate a node ID to the detector. 

The RF reading displays 00 
(MODE 7)   

1. Have Z-Wave Controller entered 

inclusion mode. 

 
Inclusion 

2. Pressing         key 3 times within 

1.5 seconds will enter inclusion mode.

flashes 

1

2

3

Front View

Side View 

Rear View

Beep tone ON 

Min.Temp./Humidity

Max.Temp./Humidity

Temperature 

°

C/

°

Humidity % 

Temp./Humid. OFF

Temp./Humid. ON 

Linking Signal

Radio Frequency 

Status 

Low Battery 

4

Содержание ST814

Страница 1: ...Exclude from a Z WaveTM Network One of function key is used to carry out inclusion exclusion association and reset When the detector is first powered up the reading in RF mode is 00 which implies that...

Страница 2: ...cation on the wall Through the 2 screw holes of the bracket mark the mounting surface with a pencil 2 Where marked drill holes into mounting surface using an appropriate size drill bit and insert the...

Страница 3: ...imit Warning If the temperature is reaching the limit the icon of MAX or MIN will be displayed on the screen Ice Warning If the temperature falls to 0 C temperature display will illuminate with LCD ba...

Страница 4: ...record press both or at the same time Threshold Limit Warning If the humidity is reaching the limit the icon of MAX or MIN will be displayed on the screen Humidity Trigger ON Press and select MODE 5...

Страница 5: ...tor has been triggered Programming 1 Z Wave s Groups Association Command Class Version 2 The Temp Humid Detector can be set to send reports to or control associated Z Wave devices It supports two asso...