1
ST814
Temperature/Humidity Detector
The Temperature/Humidity Detector is a Z-Wave
TM
enabled device which is fully
compatible with any Z-Wave
TM
enabled network. Z-Wave
TM
enabled devices
displaying the Z-Wave
TM
logo can also be used with it regardless of the
manufacturer, and ours can also be used in other manufacturer’s Z-Wave
TM
enabled networks. Inclusion of this detector on other manufacturer’s Wireless
Controller menu allows remote operation of connected modules when the
detector is triggered.
The Temperature/Humidity Detector is designed to monitor the current
temperature and humidity of ambient environment. The reading of
temperature/humidity can be reported to you on a regular base at your disposal.
If temperature/humidity reaches set points, the detector will send alerts to
associated devices for further execution. Since sudden temperature/humidity
change may cause health problems to people such as elderly or very young
children, Temp./Humid. Detector provides you most up-to-date temperature and
humidity reading for you to watch your family’s health.
Product Overview
1
LCD Screen
2
Function Keys
Select modes/Change setting
Select temperature unit/Linking
MAX
/▲
Increase settings, displays max. temperature/humidity or
enable RF & beep tone
MIN/
▼
Decrease settings, displays min. temperature/humidity or
disable RF & beep tone
3
Temperature/Humidity Sensor
4
Mounting Bracket
LCD Display
Include to or Exclude from a Z-Wave
TM
Network
One of function key (
) is used to carry out inclusion, exclusion, association
and reset. When the detector is first powered up, the reading in RF mode is 00
which implies that it hasn’t been allocated a node ID and cannot work with
Z-Wave
TM
enabled devices. The Temp./Humid. Detector will stay “awake” for
10 minutes when power is first applied to allow time for configuration. Please
get familiar with the terms below before starting the operations.
Function
Description
Inclusion
Add a Z-Wave enabled device (e.g.Temp./Humid Detector) to Z-Wave
network.
Exclusion
Delete a Z-Wave enabled device (e.g. Temp./Humid Detector) from the
network.
Association
After inclusion, you have to define the relationship between devices.
Trough association, device can be assigned as master/slave, and
specify which slave is going to be controlled by which master.
Reset
Restore Temp./Humid Detector to factory default.
The table below lists an operation summary of basic Z-Wave functions. Please
refer to the instructions for your Z-Wave
TM
Certificated Primary Controller to
access the setup function, and to include/exclude/associate devices.
Function Description
LED
Indication
No node
ID
The Z-Wave Controller does not
allocate a node ID to the detector.
The RF reading displays 00
(MODE 7)
1. Have Z-Wave Controller entered
inclusion mode.
Inclusion
2. Pressing key 3 times within
1.5 seconds will enter inclusion mode.
flashes
1
2
3
Front View
Side View
Rear View
Beep tone ON
Min.Temp./Humidity
Max.Temp./Humidity
Temperature
°
C/
°
F
Humidity %
Temp./Humid. OFF
Temp./Humid. ON
Linking Signal
Radio Frequency
Status
Low Battery
4