again after 10 seconds. If longer awake is desired, press tamper switch three 
times within 1.5 seconds will prolong its awake period to 10 minutes. 
 

3. 

With the tamper switch not being pressed, the unit enters test mode, which 

 

allows the user to make a test.    Detach the magnet from the Detector, the red 

 

indicator LED on the Detector will illuminate. 

 

4. 

When the tamper switch is pressed, the unit enters normal mode and the red 
indicator LED on the Detector will not illuminate to conserve battery life when 
the detector is triggered, (unless the battery is low). 

 

Programming 
 

1. Z-Wave’s Group (Association Command Class Version 2) 

 

The unit supports one association groups with five nodes. This has the effect that 
when the unit is triggered, all devices associated with the unit will receive the 
relevant reports.   
 

1-1 Tamper Event Report (Alarm Report) 

 

Press and hold the tamper switch more than 10 seconds then release, the unit 
will send ALARM REPORT command to the nodes of Grouping 1 to inform 
them there is a tamper event. 
 

ALARM_REPORT Command: 

[Command Class Alarm, Alarm Report, Alarm Type = 0x01, Alarm Level = 
0x11] 

 

1-2 Control other Z-Wave Devices 

 

When door/window is opened, the unit will send BASIC SET command which 
contains a value that is adjustable, to the nodes of Grouping 2. For instance, 
the brightness level of a lamp module can be fixed according to the set value.     

 

However, the BASIC_SET command will be also sent to the nodes of 
Grouping 1.    For instance, a lamp module will be turned off after receiving the 
BASIC_SET command. 
 

Basic Set Command: 
Event Present: 

[Command Class Basic, Basic Set, Value = 255 (0xFF)] 

Event Clear: 

[Command Class Switch Binary, Switch Binary Report, Value = 0x00(0)] 

 

2. Z-Wave’s 

Configuration 

 
2-1  Basic Set Level 

 
When Basic Set Command is sent where contains a value, the receiver will 
take it for consideration; for instance, if a lamp module is received the Basic 
Set command of which value is decisive as to how bright of dim level of lamp 
module shall be. 
 

   Example:  
      0: OFF 
   1-99: ON      (Binary Switch Device) 
        Dim Level (Multilevel Switch Device) 

 

Function Parameter 

Number 

Size Range 

Default 

Basic Set level 

0~99 

99 

                                             

Configuration Command 

 
2-2  Configuring the OFF Delay 

 
The Configuration parameter that can be used to adjust the amount of delay 
before the OFF command is transmitted as Configuration Parameter #2.  
This parameter can be configured with the value of 1 through 127, where 1 
means 1 second delay and 127 means 127 seconds of delay. 

 

 

 

Function Parameter 

Number 

Size Range 

Default 

Basic Set level 

0~127 

1s 

                                             

Configuration Command 

 