background image

3-1 Battery Check Command 

 
The users can also enquire the battery status of the unit by sending 
BATTERY_GET command via Z-Wave Controller.    Once the unit receives the 
command, it will return BATTERY_REPORT command. The unit will send 
Battery_Level = 255 (0xFF) command to the Z-Wave Controller to inform that 
the unit is in low battery status. 

 

BATTERY REPORT Command: 

[Command Class Battery, Battery Report, Battery Level = 20%-100%] 

 
 

3-2 Wakeup Command Class 

         
 

The unit stays in sleep status for the majority of time in order to conserve 
battery power.    However, it can be woken up at specified intervals by setting 
WAKE_UP_INTERVAL_SET command by Z-Wave Controller. After the unit 
wakes up, it will send Wakeup Notification Command to the node ID that 
requires to be reported and stay awake for 5 seconds if no 
WAKE_UP_NO_MORE_INFORMATION command is received. The minimum 
and maximum wakeup interval is 60 seconds and 194 days respectively. 
Allowable interval among each wakeup interval is 1 second, such as 60, 61, 
62 …. 

 

Note:

 The default value is 1 hour, which implies that the detector awakes and sends 

the Wakeup Notification Command to the set node every hour.     
 

4. Factory Default Setting 
 

Command Default 

setting 

Basic Set level 

99 

Period of Wake Up Notification 

    1 hour 

 

5. Command Classes 

 
The Flood Detector supports Command Classes including… 
 
*COMMAND_CLASS_SENSOR_BINARY 
*COMMAND_CLASS_BASIC 
*COMMAND_CLASS_CONFIGURATION 
*COMMAND_CLASS_WAKE_UP_V2 
*COMMAND_CLASS_MANUFACTURER_SPECIFIC 

*COMMAND_CLASS_VERSION 
*COMMAND_CLASS_ASSOCIATION_V2 
*COMMAND_CLASS_BATTERY 

 
Troubleshooting 

 

Symptom Possible 

Cause 

Recommendation 

Included a node ID 
allocated by other 
Z-Wave Controller. 
 

Exclude a node ID then 
carry out inclusion and 
association with new 
Controller. 

Cannot carry out 
inclusion and association

Does not fit batteries or 
run out of battery power.
 

Check if batteries are 
fitted or replace a new 
battery. 

Does not fit batteries or 
run out of battery power.
 

Check if batteries are 
fitted or replace a new 
battery. 

LED not illuminating and 
not working 

Break down 

Send it for repair and do 
not open up the unit. 

 
Specifications 

 

Battery 

1.5V AAA size x 3 

Range 

Up to 100 feet line of sight 

Frequency Range 

908.42 MHz (US) / 868.42 MHz (EU) 

*Specifications are subject to change without notice 

 

 

 

 

A501110873R03

 

 

 

 

                                                 

 

Federal Communication Commission Interference Statement 

This equipment has been tested and found to comply with the limits for a Class B 
digital device, pursuant to Part 15 of the FCC Rules.    These limits are designed to 
provide reasonable protection against harmful interference in a residential 
installation.  This equipment generates, uses and can radiate radio frequency 
energy and, if not installed and used in accordance with the instructions, may cause 
harmful interference to radio communications.  However, there is no guarantee 
that interference will not occur in a particular installation.    If this equipment does 

Отзывы: