background image

 

 

_______________________________________________________________________________________________________________________________ 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)20 8743 8880 

                                                                                                                                                             www.e2s.com             Fax: +44 (0)20 8740 4200 
Document No. IS 5001      Issue E             27-11-09                       

Sheet 1 of  6

 

INSTRUCTION MANUAL 

IS-mA1    Min

ia

larm 

Intrinsically Safe Round Sounder

 

 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 

1)  Introduction 

 
The  IS-mA1  minialarm  is  an  ATEX  and  IECEx  certified 
intrinsically  safe  sounder  which  produces  a  loud  warning 
signal  in  a  hazardous  area.  Forty-nine  first  stage  alarm 
sounds  can  be  selected  by  internal  switches  and  each  one 
can  be  externally  changed  to  a second  or  third  stage  alarm 
sound.  The  sounder  may  be  used  in  all  gas  groups  IIA IIB 
and IIC.  
 

2)  Description 

 
Fig  1  shows  a  simplified  block  diagram  of  an  IS-mA1 
minialarm  sounder. The  device  operates  immediately  power 
is  applied  to  the  +  and  –  terminals  which  are  duplicated  to 
allow a second sounder to be connected in parallel, or for an 
end of line monitoring resistor to be installed. The output tone 
is defined by the positions of the six internal switches and this 
tone can be changed to a second or third stage alarm tone by 
connecting  terminals  S2 or S3  to 0V.  The  tone  generator  is 
crystal  controlled  to  ensure  that  when  two  sounders 
connected to the same power supply are started at the same 
time the output tones remain synchronised. 

 

3) 

Supply Voltage

 

 
The  IS-mA1  minialarm  sounder  has  been  designed  to 
operate  in  a  hazardous  area  from  a  24V  dc supply  via  28V 
93mA  resistive ATEX  and IECEx certified Zener  Barriers  or 
Galvanic  Isolators.  The sounders  may  be  tested  or  used  in 
safe areas without a Zener Barrier or Galvanic Isolator, but at 
supply  voltages  above  16V  the  internal  current  limit  will 
function  and  therefore  it  is  recommended  that  they  are  not 
operated continuously with a direct supply greater than 16V. 
 
 
 

 
 
 

Tone Generator

Tone Selection Switches

Volume Control

IS-mA1 Sounder

_
_

S2

S3

+
+

 

 

Fig 1 Simplified block diagram 

 

4) 

Intrinsic Safety Certification

 

 

4.1 ATEX certificate 

The  IS-mA1  minialarm  sounder  complies  with  the  following 
standards:-  
 
EN60079-0:2006  
EN60079-11:2007 
EN60079-26:2007 
IEC60079-0:2007 

(used for guidance in respect of marking)

 

 

 

 
The  EC-Type  Examination  Certificate  SIRA  05ATEX2084X 
has  been  issued  by  the  Notified  Body  Sira.  This  confirms 
compliance  with  the  European  ATEX  Directive  94/9/EC  for 
Group II, Category  1G equipment.   The sounder carries  the 
Community Mark and subject to local codes of practice, may 
be  installed  in  any  of  the  EEA  member  countries.  This 
instruction  sheet  describes  installations  which  conform  to 
EN60079:Part14:2008  Electrical  Installation  in  Hazardous 
Areas.   When  designing systems  for  installation  outside  the 
UK, the local Code of Practice should be consulted. 
 
1) 

The certification marking is as follows:  

e

2S

european safety systems ltd. 

London W3 7QH UK

WARNING: 

TO AVOID A POSSIBLE ELECTROSTATIC

 

CHARGE ONLY CLEAN WITH A DAMP CLOTH 

IS-mA1 Sounder

II 1G   Ex ia IIC T4 Ga (-40ºC <=Ta<= +60°C)

0518

SIRA 05ATEX2084X

Year / Serial No. 09 / 1MA000001

Ui = 28V   Ii = 93mA   Pi = 660mW   Ci = 0    Li = 0      
Te w.r.t. Terminal -

Ui = 28V   Ii = 0mA   
Terminals S2&S3 w.r.t. Terminal -

www.e2s.com

IECEx SIR 06.0045X

0786-CPD-20338

EN54-3

Type B

VdS

 

 

2) 

The  equipment  may  be  used  in  zones  0,  1  and  2 
with  flammable  gases  and  vapours  with  apparatus 
groups  IIA,  IIB  & IIC  and  with  temperature  classes 
T1, T2, T3 and T4. 

 
 

The IS-mA1 sounder is CE marked for 

compliance with the European 

Explosive Atmospheres Directive 

94/9/EC and the European EMC 

Directive 89/336/EEC 

II 1G     Ex ia IIC T4 Ga (-40ºC <= Ta <= +60ºC) 

Reviews: