Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways, Remote Controls or
battery operated wall controllers.

Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.

Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a
Z-Wave network.

Inclusion — is the process of bringing new Z-Wave devices into a network.

Exclusion — is the process of removing Z-Wave devices from the network.

Association — is a control relationship between a controlling device and a controlled device.

Wakeup Noti cation — is a special wireless message issued by a Z-Wave device to annonces that is is able to communicate.

Node Information Frame — is a special wireless message issued by a Z_Wave device to announce its capabilities and functions.

Disposal Guidelines

The product does not contain hazardous chemicals.

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for
information regarding the collection systems available. If electrical appliances are disposed of in land lls or dumps, hazardous substances can
leak into the groundwater and get into the food chain, damaging your health and well-being.

xxx

Содержание ZME_05459

Страница 1: ...er actuators There are two different role a controller can have There is always one single primary controller that is managing the network and including excluding devices The controller may have other functions like control buttons as well All other controllers don t manage the network itself but can control other devices They are called secondary controllers The image also shows that its not poss...

Страница 2: ...ed to be connected to the cable to the load The cable from the load is connected to neutral N If there are both neutral and hot wire in the wall box the neutral from the mains panel and the neutral to the lamp need to be connected It is not harmful if the two connections L and S are mismatched on the actuator A fuse protects the electronics of the actuator The fuse is accessible on the top side of...

Страница 3: ...te operation functions to the double click of the paddles Child Protection The device can be turn into a child protection mode In this mode all local operation is disabled The child protection mode MUST be turned on wirelessly However in protected by sequence mode it is possible to unlock the device for local operation with a triple click The unlock state will last for 5 seconds LED Control Red an...

Страница 4: ...Default 1 Ignore 2 Open 3 Open if closed else close Full close time Parameter Number 4 Parameter Size 1 Time to go from opened to closed state Used to estimate the current level Note that in Permanent motion mode the reported value would a be Closed or Opened while all Basic and Multilevel Set values 1 99 255 would Open except 0 value that would Close Value Description 0 Keep in permanent motion 1...

Страница 5: ... and close relays if blind control is wired to the motor incorrectly Value Description 0 No Default 1 Yes Typical click timeout Parameter Number 10 Parameter Size 1 Typical time used to differentiate click hold double and triple clicks Value Description 1 100 in 10ms units Default 50 Invert buttons Parameter Number 11 Parameter Size 1 Value Description 0 No Default 1 Yes Switch by buttons Paramete...

Страница 6: ...ck timeout to see if the second click would be pressed This will introduce a small delay for single click commands Value Description 0 Disabled Default 4 Switch On Off and Dim send Basic Set and Switch Multilevel 1 Switch On Off only send Basic Set 2 Switch All 3 Send Scenes 5 Send Precon gured Scenes Send the following Switch All commands Parameter Number 15 Parameter Size 1 Value Description 1 S...

Страница 7: ...d Classes Basic version 1 Multilevel Switch version 3 All Switch version 1 Multi Channel version 2 Scene Activation version 1 Technical Data Power Supply 230V 50 60 Hz Attachable Loads Motors up to 1800 W Fuse Type T 1 25 A H Load 1 25 Ampere high shutdown capacity D 5 mm L 20 mm IP Rating IP 20 Frequency 868 42 MHz SRD Band Wireless Range up to 100 m outside on average up to 20 m inside buildings...

Страница 8: ...sociation is a control relationship between a controlling device and a controlled device Wakeup Noti cation is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guidelines The product does not contain hazardous chemicals Do...