“GigaBUD 1000” Installation Guide 

 

Installation Requirements: 

Category Cable: 

 

Category 5E or better cable for horizontal wiring plant per ANSI/TIA-568-C Series Standard 

 

Category patch cables 

 

Category cable 

must

 be matched throughout a Z-Band System.  Do 

not 

use a mixture of different  

             cables

 

Coax Cable: 

 

Coaxial cable backbone cannot exceed 

400’ if using RG-6, or 600’ if using RG-11 

(Use single-mode fiber 

for distances greater than 600’) 

 

Use RG-6 coaxial cables to cascade the “GigaBUD 1000’s” in the same closet 

Other Requirements: 

 

35 dB amplifier with gain and tilt for Direct Cable Feed or to increase  and flatten Headend  signals to the 
proper levels 

 

RF meter capable of measuring analog and digital signals  levels  plus C/N for analog, and MER for digital 
channels across the CATV spectrum  

 

One GigaBOB for each TV or video-enabled PC in the System 

 

Two-Way Splitter

 

Fiber Cable: 

 

Use single-mode cable with SC/APC connectors 

 

Optical wavelength:  1300  

 

RF input power range to “Z-Band Light TX”:   20 dBmV + or - 5dBmV 

 

Optical Meter capable of reading Single-mode SC/APC Terminated Fiber at 1300nm wavelength 

 

Optical input power range to “GigaBUD 1000”:   –1dBm to –4dBm 

RF Input Levels: 

Make sure that the input coming into the System is as follows (assume a 35 dB amplifier with gain and tilt is 
used prior to input, if required in order to obtain proper signal levels): 

 

  

Analog Only

 

Digital Only

 

 Analog  & Digital Combined

 

Level

 

23 dBmV 

flat

 

20 dBmV 

flat

 

23 (A) dBmV/ 17 (D) dBmV 

C/N

 

43dB or greater 

 

43 dB or greater 

MER

 

  

36 dB or greater into GigaBUD 

36 dB or greater into GigaBUD 

Figure 9 

Содержание Gen 4 "GigaBUD 1000"

Страница 1: ...Gen 4 GigaBUD 1000 Video Distribution System Installation Guide October 2014 Version 5 2...

Страница 2: ...power from the unit SHOCK HAZARD The video hub and remotely powered balun System meet UL CSA Listed compliance criteria as well as being FCC Part 15 Subpart B Compliant WARNING Failure to follow this...

Страница 3: ...BUD Video Hub 1000 GigaBUD 1000 In the Horizontal the AGC is maintained by the Z Band Intelligent GigaBOB at each Receiver The AGC in a coax based Backbone is designed to maintain Video Signal Integri...

Страница 4: ...picts a Basic Layout of a System with a Singlemode Fiber Backbone Depicts a Basic Layout os a System with a Co Figure 1 Figure 2 Depicts a Basic Layout of a System with a Coaxial Backbone Notice that...

Страница 5: ...1000 and Separated at the GigaBOB A port from the Ethernet Switch is plugged into the top row Aux of the GigaBUD and is com bine with the RF Video that is on the bottom row At the GigaBOB the RF Vide...

Страница 6: ...F connector input The Status Light will be Green when the proper input levels are received The input level can be 20dBmV or 5 but it is best to get them as close to 20dBmV as possible so that variati...

Страница 7: ...eo Hub 1000 4 2 6 10 12 RF VIDEO BROWSER PORT GigaBUD IP Video Hub 1000 4 8 12 16 20 24 MASTER SLAVE POWER STATUS CATV Inbound Outbound Cascade In Cascade Out FIBER INPUT 90 264 VAC 47 63Hz 150W 2A Fu...

Страница 8: ...Auxiliary IP Out Horizontal Cable In From Wall Outlet Horizontal Cable In Auxiliary IP Out Wall Mount Balun with Diplexer Free Hanging Balun Avail With or Without Diplexer Figure 8 Light s On denotes...

Страница 9: ...of measuring analog and digital signals levels plus C N for analog and MER for digital channels across the CATV spectrum One GigaBOB for each TV or video enabled PC in the System Two Way Splitter Fibe...

Страница 10: ...o the Z Band Light Transmitter or to the Master GigaBUD 1000 s If Singlemode Fiber Patch Panels are Terminated with Connectors other than SC APC special Patch cords must be acquired to address the Inc...

Страница 11: ...nnected to the coax Cascade In port of up to 8 Level 2 satellite GigaBUD 1000s Each Level 2 device can then connect to up to 8 Level 3 devices and each Level 3 device can connect to up to 8 Level 4 de...

Страница 12: ...d 4 Levels Level 1 Level 2 Level 2 Level 2 Figure 10 Figure 11 Figure 10 depicts the Cascade connections that are typical in a closet containing a Fiber Master Notice that all of the Satellite devices...

Страница 13: ...com 866 902 2606 13 GigaBUD 1000 Installation Guide Fiber Backbone to Every Closet Figure 12 Figure 12 depicts the fiber connections from a Z Band Light Transmitter to a Fiber Master in each closet of...

Страница 14: ...BUD 1000 Installation Guide Coax Backbone to Every Closet Figure 13 IDF 1 MDF IDF 3 IDF 2 IDF 5 IDF 4 Figure 13 depicts the coax connections from a non fiber GigaBUD 1000 Master to Level 2 Satellite d...

Страница 15: ...nstallation Guide Fiber Backbone to Every Closet Coax Backbone Cascade within the Closets Figure 14 Figure 14 depicts a typical Campus installation using a Fiber Backbone to each closet in multiple bu...

Страница 16: ...tone is a unique signal sent out so that the Satellite units connected can set their levels properly for signal balance A yellow Fourth light indicates that the pilot tone is on and is active Master C...

Страница 17: ...native state GigaBUD 1000 FUNCTIONS Master Satellite While in Master and the button is held for 5 seconds the unit will stop broadcasting the tone and the light will change from yellow to green Holdin...

Страница 18: ...g the splitter in the System will allow for reading the input signal level and quality MER or C N without disconnecting the System Master GigaBUD CATV Inbound Outbound Cascade In Cascade Out FIBER INP...

Страница 19: ...ctional applications CATV Inbound Outbound Cascade In Cascade Out FIBER INPUT CATV Inbound Outbound Cascade In Cascade Out FIBER INPUT COAX Slave Level 3 Slave Level 4 COAX COAX COAX To Master or Leve...

Отзывы: