Yuwell M102 Скачать руководство пользователя страница 18

ii. List of accessories

iii. Waste and residue treatment

Attachment

Main unit
Medication cup module
Mask
Mouth piece
Battery
Instruction manual
Warranty (Certificate)
Power cable

Quantity

1
1
2 (1 for Adult and 1 for child) 
1
2
1
1
1

If there is any need for parts and accessories, please contact the 
supplier.

Name and Content of Toxic and Harmful

Substance or Element Contained in Product

Toxic and Harmful Substance and Its Compound or Element

Metal parts

Lead and its

compound

≤1000PPM

Mercury and

its compound

≤1000PPM

Cadmium and

its compound

≤100PPM

Hexavalent

chromium and

its compound

≤1000PPM

PBB

≤1000PPM

PBDE

≤1000PPM

Parts

Note:

1.  Please  read  through  this  Manual  carefully  before  using  the 
product.
2.  The  Company  bears  no  liabilities  for  the  machine  damage  and 
faults  caused  by  improper  use  or  failure  in  operating  as  per  this 
Manual
3. The main unit may not be operated if the temperature, voltage and 
product characteristics are different from the indicators specified.
4. Poduct performance may vary along with the liquid characteristics 
(suspension or high viscosity).
5.  See  the  external  package  label  or  certificate  for  the  date  of 
production.

○: It means the contents of the toxic and harmful substance in all homogeneous materials of the 
part are below the limit as specified in GB/T26572-2011 standard.
Note: Lead in steels, aluminum and copper is ≤3,500 PM, ≤4,000 PM and ≤4% respectively 
and the contents of six toxic and harmful substances of all packages are ≤100 PPM.

The waste main unit, accessories and specially sold products shall be 
treated by conforming to the requirements of local government.

Battery

Plastic and

polymer parts

Circuit board

components

3. If necessary, please provide circuit diagrams and repair informa-
tion. If there is any difficult problem in repairing the electrical circuit, 
please contact the manufacturer.

30

31

We retain product technique and appearance change rights and will 
not send a prior notice in case of change!

Содержание M102

Страница 1: ...CE M102 180x110mm 90x110mm 2...

Страница 2: ...CO LTD Manufacturing Address Yunyang Industrial Park Danyang Jiangsu http www yuwell com TEL 86 511 86900833 Postal code 212300 European Representative Name Shanghai International Holding Corp GmbH E...

Страница 3: ...use Atomized drug used in treatment is applicable to domestic fog inhalation therapy ii Product features and indexes 1 Power supply 3V DC two AA 1 5V alkaline batteries Alternative Power adapter inpu...

Страница 4: ...using when storage temperature is below 5 The product should be stored in room with excellent ventilation and avoid violent vibration during transportation Transport should only be undertaken in the c...

Страница 5: ...imely II Using and Maintenance In order to ensure the product can be correctly used please read this Specification carefully and operate the product in strict accordance with this Specification If any...

Страница 6: ...attery cover Do not mix different types of batteries together When ow voltage indicator LED orange flicks it means battery level is about to run out at this time replace alkaline battery as soon as po...

Страница 7: ...d high viscosity suspending and volatile liquid Confirm medication cup module is well mounted it will be buckled after slight clatter sound is given off ensure electrode is excellently connected so as...

Страница 8: ...soft high frequency sound will be generated and the nebulizer will be shutdown automatically With difference of liquid feature nebulizer cannot be automati cally shut down when part of liquid is run o...

Страница 9: ...ssing through a short starting stage below 2 s Do not cover air hole with hands or other objects when mask is used in inhalation Steadily hold nebulizer with hands during inhalation There is a small a...

Страница 10: ...g after nebulization and should not be used in normal liquid inhalation 2 Cleaning 1 Main unit Wipe stains on main unit gently with wet gauze then wipe main unit with new gauze to make it dry 2 Clean...

Страница 11: ...ies used should be kept separately with main unit To avoid the strangulation keep the children away from the excessive length s Power cable If any discomfort or abnormality occurs stop using the unit...

Страница 12: ...10s Restart after medication cup module is reassembled Incline the positive surface of nebulizer to the user and make liquid contact spray sheet Clean medication cup according to operation instruction...

Страница 13: ...automatically Liquid leakage The electrode of main unit or medication cup is dirty Fault of medication cup module Power off nebulizer to clean electrode Change a new medication cup module Medication...

Страница 14: ...ectro magnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation Medical devices should also not interfere with other devices In order to r...

Страница 15: ...nment If the user of the M102 nebulizers requires continued operation during power mains interruption it is Recommendthat the M102 M103 be powered from an uninterruptible power supply or battery 3 A m...

Страница 16: ...transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with he fol...

Страница 17: ...ged caused by unforeseen natural disasters such as floods earthquakes fires etc 28 29 Table 4 Recommended separation distances Recommended separation distance between portable and mobile RF communicat...

Страница 18: ...if the temperature voltage and product characteristics are different from the indicators specified 4 Poduct performance may vary along with the liquid characteristics suspension or high viscosity 5 Se...

Отзывы: