Install-MONTE_BASE - SEP_2015.doc                  www.yunca.co.nz  

Page 2 of 4 

 
MONTE BASE WOODBURNER 

– TYPICAL FLUE INSTALLATION                                                    

(drawings on the following pages not drawn to scale)

 

 

FIG A MONTE BASE WOODBURNER Flue Mounted Shield 
(STD Flue Guard) Kit Installation  

Complies (with heater) to AS/NZS 2918:2001  
 
 

 

 

 

 

 
 
 
 

CEI LI NG PLATE

2 5 m m  m in . BET WEEN LI NER &  ANY TI MBER

ENLARGEMENT  OF CEI LI NG ASSEMBLY

3 0

0

3 0 0 m m  Sq. T I MBER FRAME

TIMBER RAILS

SUPPORT ANGLES

LINER POSITIONED BY SPIDER
BRACKETS. TOP/BOTTOM

INSULATION BOUNDARY SHIELD

CUT  CEI LI NG MAT ERI AL
BACK 2 5 m m  CLEAR
OF BOUNDARY SHEI LD.

CEI LI NG

2 5

3 0

0

 

 

CONDITIONS FOR FLUES 

(Refer Fig. E) 

 

1. 

The FLUE shall extend to: 
 
Not less than 600mm above the highest 
point on the roof if within 3.0m of that point, 
or 
Not less than 1000mm above the 
intersection point with the roof and not lower 
than any point of the roof within 3.0m. 
 
In any case the length of the flue shall not be 
less than 4.6m from the ash floor protector. 
 
In some situations the Local Council may 
vary the above requirements. 
 

2. 

The flue system must be tested and comply 
with AS/NZS2918:2001, Appendix F. 

 
3. 

The insulation boundary shield shall be 
capable of preventing accidental migration of  
loose-fill or any combustible material by any 
action of wind or by persons moving in the 
ceiling space.

 

 

FIG B. 

 

 

 

 

 

These instructions spare parts information, 
operation and maintenance guides may be 
downloaded from www.yunca.co.nz 

FIG B

 

 

Ash floor Protector 

10mm GAP BETWEEN 
TOP PLATE LIP AND 
U/SIDE FLUE GUARD  

Содержание MONTE BASE Clean Air Sub 1.0

Страница 1: ...straint E Manufacturers recommended tested minimum clearances from combustible walls Tested to AS NZS 2918 2001 by APPLIED RESEARCH SERVICES LTD Clearance Rear Clearance with YUNCA STD FLUE GUARD fitted 200mm Side Clearance with YUNCA STD FLUE GUARD fitted 450mm Corner Clearance with YUNCA STD FLUE GUARD fitted 280mm F YUNCA Flue Kit Complies with AS NZS 2918 2001 Appendix F FIG A B E 1 4 2m x 150...

Страница 2: ...ss than 600mm above the highest point on the roof if within 3 0m of that point or Not less than 1000mm above the intersection point with the roof and not lower than any point of the roof within 3 0m In any case the length of the flue shall not be less than 4 6m from the ash floor protector In some situations the Local Council may vary the above requirements 2 The flue system must be tested and com...

Страница 3: ...UNTED SHIELD FITTED Measurements in millimetres A B E F G H 200 450 280 366 782 600 FIG D MINIMUM FLOOR PROTECTION MEASUREMENTS WITH YUNCA FLUE MOUNTED SHIELD FITTED Measurements in millimetres C D J K L M N O P 300 125 913 999 1481 1288 633 663 699 Note All Dimensions are in millimetres Above Non combustible wall clearances Brick lining From the floor to within 25mm of ceiling Leave air vents at ...

Страница 4: ...E MARKING TESTED TO AS NZS 4013 C ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS NZS 4013 D MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS WHERE SUCH ACTION IS...

Отзывы: