LEEDZ INFRA-RED REMOTE CONTROL with AUTO TIMER.

 

 
POWER ON/OFF:

 

First check that two fresh AAA batteries are inserted.  If the remote appears faulty, 

please try replacing the batteries. At first the remote may appear to be on, but it is likely that is not so.  
 
To turn on the remote control (it is protected with a “kiddy lock”), press and hold the 

POWER

 button for 

about 2 seconds until “off” disappears from the screen, then release to unlock the safety feature. One 
short press of the 

POWER

 button will turn on power to the remote control, and also start the fire on the 

MANUAL - HIGH setting. Current mode / settings will be displayed. The fire will always start in manual 
operating mode on a high setting. (Also refer to the next page for further information). There is an audible 
beep when the fire receives a signal from the remote, range is approximately 5 metres. 
 

CLOCK SETTING: 

Press the 

CLOCK

 button once (“clock” in the display

 will start flashing). Press 

WEEK

 to set the week day, press 

HOUR

 to set the hour, taking care to check if on a.m. or p.m. Press 

MIN 

to set the minute (holding the button down will advance the minutes quicker). Press 

CLOCK 

to save 

the setting.  

 

MANUAL “FLAME” OPERATING MODE

 h

as three settings: High, Medium and Low. Heat output is 

fixed to the setting and needs to be adjusted manually by pressing the 

TEMP

 “ – “ and “ + “ buttons. 

 

“FUZZY LOGIC” OPERATING MODE 

r

eplaces the traditional thermostat operation with six “comfort 

levels”. Press 

MODE

 to switch between 

Manual

 and 

Fuzzy Logic

, and use the 

TEMP

 “ 

 “ and “

 +

 “ 

buttons. Choose the comfort level that best suits your needs. Every now and then the fire will give a short 
boost of heat and then return to your chosen setting. This is the most economical way to operate your 
Yunca Fuzzy Logic control fire. 

 

HINT

: The two speed fan is designed to quickly transfer heat around the room and ensures the most 

economic gas use. The three-position switch (HIGH / OFF / LOW) is located on the right side plinth. 

 
AUTO FUNCTION

To set this feature you will need to ensure the remote control is on (as advised 

above), and ensure the 

CLOCK

 time and day are correctly set. 

PLEASE NOTE:

 If a key is not pressed for 

7 seconds, the programming will “time out” and you will need to re-start the process. 
 
Set times to Start and/or Stop the fire with a choice of up to two daily programme settings (

PROG1

 and 

PROG2

). You can choose to use only 

PROG1

 if only one setting is needed. Heat output on Auto is 

initially run in manual control, and once the fire is operating you can then switch to the more economical 
Fuzzy Logic. 

 

EXAMPLE

: Set 

PROG1

 to start at 6:00 am, stop at 8.00am. Set 

PROG2

 to start at 4.30pm, stop at 

10.30pm Monday to Friday. Both 

PROG1 

and

 PROG2 

may have different settings programmed for the 

weekend if required. 
 

TO SET: 

Press 

PROG1 

to set the “timer on” setting (Mon-Fri). Now choose the desired heat output (High, 

Med or Low) Press 

HOUR

 button, making sure you have chosen the correct a.m. or p.m. time, then press 

MIN

 button (increases in 10 minute steps) to set the start time. Press 

PROG1

 again and use the 

HOUR

 / 

MIN

 buttons to set the stop time. Press 

CANCEL

 at any time to clear the setting currently on screen 

(i.e.either Start or Stop). If you are not setting weekend programming, just press 

PROG1 

to save your 

settings and exit the programming function. 
 
If you wish 

PROG1

 to operate on Saturday and Sunday, press 

WEEK

 button to set start time, using 

HOUR

 and 

MIN

 buttons as described above. Then press 

PROG1 

again to set the weekend stop time, and 

press 

PROG1 

once more

 

to save your settings and exit the setting mode. 

 

 

Continue as above using 

PROG2

 if required. To check the programme settings press either Prog1 or 

Prog2. 
 

…Important Info 

Continued on page 10…

 

Содержание LEEDZ

Страница 1: ...Fuzzy Feb 2010 Page 1 of 19 LEEDZ FUZZY LOGIC control FREESTANDING GAS HEATER FEBRUARY 2010 INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION These instructions should be stored in a convenient...

Страница 2: ...CONTROL AUTO TIMER 8 10 MANUAL CONTROL OPERATION 11 MAINTENANCE DOOR REMOVAL GLASS REPLACEMENT 11 GLASS CLEANING DOOR ROPE REPLACEMENT 12 BATTERY BACK UP 12 SERVICE INSPECTION AND CLEANING 13 GAS CON...

Страница 3: ...k controls for added peace of mind We highly recommend the use of the two speed fan boost on the fire for greater heating efficiency Should power not be available for any reason battery back up throug...

Страница 4: ...fitted When the appropriate position has been selected the unit must be bolted to the floor to ensure that the unit remains upright in the event of an earthquake or similar Fig 1 below If the heater...

Страница 5: ...case the length of the flue shall not be less than 3 metres from the top of the appliance flue spigot 2 When loose fill insulation is used in the adjacent ceiling space maintain clearance between the...

Страница 6: ...below Fig 3 and comply with NZS 5261 AG601 This is to ensure adequate air circulation around the heater and avoid heat damage to wall coverings Note If walled surface is non combustible i e brick or...

Страница 7: ...d be tested for leaks before operating the heater TO CHECK GAS PRESSURE 1 Remove the front plinth cover two screws at top of cover 2 Test point can be seen on the left side of the control box 3 Slacke...

Страница 8: ...Revised 04 08 10 YUNCA Leedz FS Fuzzy Feb 2010 Page 8 of 19 LEEDZ INFRA RED REMOTE CONTROL with AUTO TIMER N B DO NOT LEAVE THE REMOTE CONTROL ON TOP OF YOUR FIRE...

Страница 9: ...our Yunca Fuzzy Logic control fire HINT The two speed fan is designed to quickly transfer heat around the room and ensures the most economic gas use The three position switch HIGH OFF LOW is located o...

Страница 10: ...ou will see the AUTO symbol display on the LCD screen of the remote control unit IMPORTANT Press AUTO SET button again to cancel the auto feature or the fire will continue to operate to the automatic...

Страница 11: ...ove the front door as described above and place front down on a soft surface 2 Remove the two side glass retainers by taking out the three bolts in each one 3 Remove the bottom front glass retainer by...

Страница 12: ...page 2 Remove the existing gasket and clean the channel of all loose material 3 Lay a thin bed of gasket cement PVA glue around the length of the channel 4 Lay the gasket in the channel ensuring the...

Страница 13: ...g it up and out Brush it gently over a newspaper and carefully place it out of the way 3 The bark tray can be removed by lifting its feet over the bottom gasket retainer and pulling it straight out wi...

Страница 14: ...1 Remove front cover 2 Disconnect the wiring from switch 3 The earth wire must be unplugged and the plastic conduit adaptor removed from its retaining bracket 4 Disconnect earth wire from control valv...

Страница 15: ...to replace Pilot Set or drill the injector Nozzle diameter LPG 0 35 mm NG 0 55 mm Replace POSSIBLE CAUSE AC Power IS unplugged or loose or the fuse has a short Battery power is too low when using DC p...

Страница 16: ...he terminals have loosened Valve M has a failure or Nozzle of Valve M is blocked Front Control Board has a failure Remote Control Unit has a failure The wire set has a failure or the terminals have lo...

Страница 17: ...ition rocker switch 6699 Fan only unwired QLZ06 1200 A49 6624G Fan assembly complete 6611G Otago Bay Log Set assembly 6611C Logset twig 88 LFzR Right side panel State Colour 88 LFzL Left side panel St...

Страница 18: ...r any other indirect incidental cause are not covered by this warranty This warranty is void if the recommended service schedule is not implemented and carried out by a suitably qualified person as su...

Страница 19: ...urchased Installed By Date Designed and Manufactured by Yunca Gas Dunedin PO Box 500 DUNEDIN 9054 Telephone 03 488 4342 Email dunedin yunca co nz Cut along here This section must be completed and retu...