SOLUTION 

 

Reset the Power Plug or replace the Fuse. (fuse box is 

located below “AC in”, and slides out, spare fuse within) 

Change battery or adjust the connector pins 
Replace the Battery Box. 

Uncover the IR Receiver. 

Press POWER button for 2 seconds and release, then 

press POWER button again.  

Replace with new batteries or manually press the PWR 

button on the front plate (Fig 4, page 11).  

Check remote control batteries. 

Re-arrange the connection wires or replace with a new wire 

When replacing the wire set, use (-) type screwdriver to first 

remove the plastic cover. 

Replace Rear Control Board first. If still not working replace 

Front Control Board. 

Adjust the gap to 4 ± 0.5 mm.  
(Cable Resistor should be connected close to spark Igniter.) 

Replace with a new one. 

Reset or replace with a new one. 

Pilot tube must be grounded (Fix on the Control Valve) 

Replace with a new one. 

Check Test Point (by manometer) for gas pressure (Pg 7). 

 

Re-arrange or replace a new wire set.  

If there is gas pressure, it's necessary to replace Pilot Set or 

drill the injector.  

Nozzle diameter: LPG: 0.35 mm, NG: 0.55 mm. 

Replace. 

POSSIBLE CAUSE 

 

AC Power IS unplugged or loose, or the fuse has a short 

 

Battery power is too low when using DC power 

 

Battery Box has a failure or the connector pins are loose. 

 

IR Receiver (Fig 4) is covered.  

 

POWER button of Remote Control Unit was not pressed for 

long enough.  

 

Remote Control Unit has failed or there is no battery 

power.  

 

The connection wires between Front Control Board and 

Rear Control Board are loose or have failed. 

 

Front and Rear Control Board have a failure.   

 

Gap between Spark Igniter and Grounding or sparking 

gap is too big 

 

Ceramic of Spark Igniter breaks or fails 

 

High Voltage Cable has loosened, broken or has a short. 

 

Pilot Set is not grounded. 

 

Rear Control Board has a failure. 

 

No gas supply. 

 

Poor wire connection between Front and Rear Control 

Board or connection wires have loosened. 

 

Pilot Injector is blocked. 

 

Rear Control Board has a failure. 

TROUBLESHOOTING GUIDE –YUNCA FUZZY LOGIC CONTROL SYSTEM  P1/2 

PROBLEM 

 

 
A. After turning on the 
appliance it will not operate, 
the PWR (power) indicator 
on the control panel (Fig 4) is 
not lit up. 

 
B. After turning on the 
appliance, it will not spark. 
 
 

 
C. Sparking exists but pilot 
flame will not light up. 
 

 

Содержание LEEDZ

Страница 1: ...Fuzzy Feb 2010 Page 1 of 19 LEEDZ FUZZY LOGIC control FREESTANDING GAS HEATER FEBRUARY 2010 INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION These instructions should be stored in a convenient...

Страница 2: ...CONTROL AUTO TIMER 8 10 MANUAL CONTROL OPERATION 11 MAINTENANCE DOOR REMOVAL GLASS REPLACEMENT 11 GLASS CLEANING DOOR ROPE REPLACEMENT 12 BATTERY BACK UP 12 SERVICE INSPECTION AND CLEANING 13 GAS CON...

Страница 3: ...k controls for added peace of mind We highly recommend the use of the two speed fan boost on the fire for greater heating efficiency Should power not be available for any reason battery back up throug...

Страница 4: ...fitted When the appropriate position has been selected the unit must be bolted to the floor to ensure that the unit remains upright in the event of an earthquake or similar Fig 1 below If the heater...

Страница 5: ...case the length of the flue shall not be less than 3 metres from the top of the appliance flue spigot 2 When loose fill insulation is used in the adjacent ceiling space maintain clearance between the...

Страница 6: ...below Fig 3 and comply with NZS 5261 AG601 This is to ensure adequate air circulation around the heater and avoid heat damage to wall coverings Note If walled surface is non combustible i e brick or...

Страница 7: ...d be tested for leaks before operating the heater TO CHECK GAS PRESSURE 1 Remove the front plinth cover two screws at top of cover 2 Test point can be seen on the left side of the control box 3 Slacke...

Страница 8: ...Revised 04 08 10 YUNCA Leedz FS Fuzzy Feb 2010 Page 8 of 19 LEEDZ INFRA RED REMOTE CONTROL with AUTO TIMER N B DO NOT LEAVE THE REMOTE CONTROL ON TOP OF YOUR FIRE...

Страница 9: ...our Yunca Fuzzy Logic control fire HINT The two speed fan is designed to quickly transfer heat around the room and ensures the most economic gas use The three position switch HIGH OFF LOW is located o...

Страница 10: ...ou will see the AUTO symbol display on the LCD screen of the remote control unit IMPORTANT Press AUTO SET button again to cancel the auto feature or the fire will continue to operate to the automatic...

Страница 11: ...ove the front door as described above and place front down on a soft surface 2 Remove the two side glass retainers by taking out the three bolts in each one 3 Remove the bottom front glass retainer by...

Страница 12: ...page 2 Remove the existing gasket and clean the channel of all loose material 3 Lay a thin bed of gasket cement PVA glue around the length of the channel 4 Lay the gasket in the channel ensuring the...

Страница 13: ...g it up and out Brush it gently over a newspaper and carefully place it out of the way 3 The bark tray can be removed by lifting its feet over the bottom gasket retainer and pulling it straight out wi...

Страница 14: ...1 Remove front cover 2 Disconnect the wiring from switch 3 The earth wire must be unplugged and the plastic conduit adaptor removed from its retaining bracket 4 Disconnect earth wire from control valv...

Страница 15: ...to replace Pilot Set or drill the injector Nozzle diameter LPG 0 35 mm NG 0 55 mm Replace POSSIBLE CAUSE AC Power IS unplugged or loose or the fuse has a short Battery power is too low when using DC p...

Страница 16: ...he terminals have loosened Valve M has a failure or Nozzle of Valve M is blocked Front Control Board has a failure Remote Control Unit has a failure The wire set has a failure or the terminals have lo...

Страница 17: ...ition rocker switch 6699 Fan only unwired QLZ06 1200 A49 6624G Fan assembly complete 6611G Otago Bay Log Set assembly 6611C Logset twig 88 LFzR Right side panel State Colour 88 LFzL Left side panel St...

Страница 18: ...r any other indirect incidental cause are not covered by this warranty This warranty is void if the recommended service schedule is not implemented and carried out by a suitably qualified person as su...

Страница 19: ...urchased Installed By Date Designed and Manufactured by Yunca Gas Dunedin PO Box 500 DUNEDIN 9054 Telephone 03 488 4342 Email dunedin yunca co nz Cut along here This section must be completed and retu...