Revised 27/05/10
ALLURE Outdoor Install May2010
Page 13 of 17
COMMISSIONING
When installation is complete, the installer must operate the YUNCA ALLURE OUTDOOR to
ensure that all features are operating safely and correctly, refer to instructions below.
OPERATING YOUR YUNCA ALLURE OUTDOOR FIRE
NEVER OPERATE YOUR FIRE WITH THE COVER IN PLACE.
The markings mentioned below are imprinted on the Control
Panel Grill and are visible when the hearth panel is lifted out
Note: You do not need to remove the hearth panel to light the
fire.. Some models may have a black box behind the control
panel grill with similar markings, however the method of lighting is
the same.
1. To ignite your fire, push the control knob fully in and turn anti-clockwise (left) to the “Ignition”
position (you will feel a slight resistance), hold in for 5-15 seconds.
2. Continuing to hold the control knob in, turn it further anti-clockwise to pilot mark (you will hear
a click).
3. When the pilot is lit, continue holding in the knob for about 20 seconds to allow the safety
thermocouple to heat up.
Slowly
release the knob and the pilot flame should remain lit. If it
goes out repeat steps 1 - 3.
4. The control knob can now be turned further anti-clockwise (left) to the ON position to fully light
the fire. Adjust flame height and heat output as required.
Turning off
1. Turn the control knob clockwise to the off position.
WARRANTY
:
A limited Five-Year Warranty covers the Yunca Allure Outdoor Gas Open Fire against defects in materials
and workmanship.
All gas components including burners, pilot assembly and tubing, are
warranted for a period of one year
from date of purchase
.
Damage caused by neglect, improper use, acts of god, theft, or any other indirect, incidental cause are not
covered by this warranty.
ALLURE OUTDOOR series fires are specifically designed for OUTDOOR USE ONLY and CANNOT
be used indoors.
If you are in any doubt please contact the manufacturer: Yunca Gas, Dunedin 03 488 4342
N.B. DUE TO ADVERSE CONDITIONS (e.g. salt air) the ALLURE OUTDOOR fire will NOT be covered
under warranty for fires situated closer than 500m to the shoreline.
This warranty is void if the recommended service schedule is not implemented as suggested in
this manual and such servicing is not carried out by a suitably qualified person
.
Limitations of Liabilities:
Yunca Heating hereby waivers any liability for incidental and consequential damage directly or indirectly
sustained, or for any loss caused by the application of this product not in accordance with the current
printed instructions.
Our liability is expressly limited to replacement of defective goods as per above warranty. Any claim shall
be deemed waived unless made in writing to Yunca within 30 days from the date that it was or reasonably
should have been discovered.