manualshive.com logo in svg
background image

Revised 27/05/10 

 

 

 

ALLURE Outdoor Install May2010 

 

 

Page 7 of 17

 

CONNECTION TO GAS SUPPLY 

AND TESTING PRESSURES 

 

GAS SUPPLY: 

Burn only the fuel for which the appliance is equipped. The data plate affixed to the base of the appliance 
specifies the gas type, which the appliance is factory equipped for. 

 

CONNECTION:

 

The gas inlet is a  3/8” BSP pipe. 
 

 

A  separate  gas  isolation  valve  should  be  installed  immediately  up  stream  of  the 
connection to the appliance.  
    

Important

:

 Gas Pipe sizing:

 The supply pipe size should be determined from NZS 5261 to 

ensure correct gas supply to the appliance. Incorrect pipe sizing 

WILL

 affect the performance of this 

appliance. 

 

WARNING:

 

To stop pipe compounds entering the gas line, do not apply sealing compounds to the 

first two threads at the tip of any gas connection.  All joints should be tested for leaks before operating the 
fire. 

 

Gas pressure requirements:

 

 

Correct gas pressure and the use of a properly sized gas supply line are essential for the safe and efficient 
performance of this appliance. The inlet and outlet pressures at the control must be tested on installation. 
Note: Improper gas pressure will affect fire performance, flame colour or cause pilot malfunction. 

 

Natural Gas: 

Input  

930:

 53 MJ,   

 

730:

 50 MJ,  

Minimum inlet pressure 

1.25 kPa  (5"w.g.) 

Maximum inlet pressure 

5.0  kPa  (20"w.g.)  

Max Manifold Operating pressure 

0.6  kPa  with Burners on HIGH 

 

0.25 kPa  with Burners on LOW 

LPG: 

Input 

930 & 730: 

48 MJ   

Minimum inlet pressure 

2.75 kPa  (11"w.g.) 

Maximum inlet pressure 

3.5  kPa  (14"w.g.)  

Max Manifold Operating pressure 

1.5  kPa  with Burners on HIGH   

 

 

0.7 kPa  with Burners on LOW 

 
 

CAUTION: Do not use this appliance if any part has been water damaged or exposed to 
moisture causing corrosion. 
 
A Qualified service technician should inspect the appliance and replace any part of the 
gas system that has been water damaged. 

 
 

Содержание 930

Страница 1: ...URE OUTDOOR GAS OPEN FIRE Stainless Steel Fascia 930 730 MODELS May 2010 INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION These instructions should be stored in a convenient safe place for read...

Страница 2: ...pendix A FAULT FINDING GUIDE 14 Appendix B SPARE PARTS LIST 15 16 Appendix D WARRANTY REGISTRATION CUSTOMER COPY 16 ATTACHMENT WARRANTY REGISTRATION MANUFACTURER COPY INTRODUCTION Welcome and congratu...

Страница 3: ...IN THE VICINITY OF THIS APPLIANCE WHILE IT IS OPERATIONAL NEVER OPERATE THE FIRE WITH THE COVER IN PLACE STAINLESS STEEL FASCIAS and WEATHER COVERS are shipped with protective plastic in place to red...

Страница 4: ...ble is a Bottom Fascia Strip for each model This strip 85mm high is fitted below a regular three sided fascia for a picture frame look TIMBER FRAMES Should a timber frameout be used outdoors then the...

Страница 5: ...e cap is 1200mm i e one standard flue length Flue and Liner should be fitted with top and bottom spacer brackets STAINLESS STEEL FASCIA WEATHER COVER Gutter Strip A gutter strip is fitted to run any w...

Страница 6: ...ted before the fire is finally positioned Fig 2 6mm dia x 50mm Coach Bolts Supplied If the appliance is being attached to a concrete floor dyna bolts should be used If the floor is wooden the bolts us...

Страница 7: ...d for leaks before operating the fire Gas pressure requirements Correct gas pressure and the use of a properly sized gas supply line are essential for the safe and efficient performance of this applia...

Страница 8: ...e tested at the test nipple on the side of the BM 733 control Operating pressure is adjusted at either the LPG or NG in line regulator Gas Type Pressures and jet sizes appear on data plate The Allure...

Страница 9: ...bottom strip is fitted using two screws 4 TOP LOUVRE 1 Top Slides out for easier access to the top front cowl and flue spigot refer 7 May be left in place if access to the flue spigot is not required...

Страница 10: ...ve screw from centre hole and lift out 5 Rear Tray Remove screw from right and left side lift out 6 Burners Lift out 7 Manifold Baffles Lift out left and right baffles SETTING THE FIRE 1 Replace all p...

Страница 11: ...per row The 730 model uses 10 coals per row layout as shown below from left to right Bottom Rear Row Bottom Front Row Top Rear Row Top Front Row 930 26 x No1 Coals 26 x No2 Coals 4 rows of 13 730 20 x...

Страница 12: ...3 x No1 13 x No2 730 10 x No1 10 x No2 Layout shown is for the 930 model using 13 coals per row The 730 model uses 10 coals per row layout as shown below from left to right Rear Row Front Row Logs 930...

Страница 13: ...output as required Turning off 1 Turn the control knob clockwise to the off position WARRANTY A limited Five Year Warranty covers the Yunca Allure Outdoor Gas Open Fire against defects in materials an...

Страница 14: ...t No Gas Supply LPG Check gas cylinder arrange refil Natural Check with gas supplier Pilot will not stay lit Weak or improperly located pilot flame Adjust the height of thermocouple The flame should e...

Страница 15: ...jector burner 930 specify LPG or NG NAT Burner Plug Insert 6505 Delta Pilot Burner Assembly with Spark Electrode 6606GO Pilot Pipe 6502 BM733 Control Valve 6513P Thermocouple Spark electrode 6791GO9 9...

Страница 16: ...op Louvre 2 at bottom Hearth Weather Cover Key where an appears this substitutes for the model number i e 9 930 7 730 CUSTOMER COPY YUNCA ALLURE OUTDOOR STAINLESS STEEL WARRANTY REGISTRATION PLEASE CO...

Отзывы: