Right Method
Wrong Method
Figure 7-8
c) To be sure the coating fiber was pressed tightly by the hold
clamp. The shield was closed, the fiber should be pressed
on the V-groove by the shield.
7.5 Arc Power Test
Arc Power Test is very important for obtaining low splice loss.
So before splicing, the test should be done. See the details in
the appendix A.
7.6 Splicing Operation
There are three splicing modes for selection: Manual,
Semi-auto and auto splicing mode.
7.6.1 Manual splicing mode
(1) Strip, clean and cleave the optical fibers.
(2) Open the shield.
(3) Lift the fiber clamps.
(4) Place the optical fibers in the V-grooves.
(5) Carefully close the V-groove clamps. Ensure the bare
fibers are seated at the position between the V-groove and