This manual contains important instructions to follow during installation and maintenance of the
Yotta
DPI-208 and DPI-480
Grid Support Utility Interactive Microinverter. To reduce the risk of electrical shock
and ensure the safe installation and operation of the
DPI-208 and DPI-480 Microinverter
, the following
symbols appear throughout this document to indicate dangerous conditions and important safety
instructions. Specifications are subject to change without notice - please ensure you are using the most
1. Important Safety Instructions
This symbol indicates a situation where not following instructions may cause a seri-
ous hardware or safety issue and/or put people in danger. Be extremely cautious
when performing this task.
This symbol provides important indication to follow in order to optimize the DPI-208
and DPI-480 Microninverters operations. Follow these instructions closely.
- Do
NOT
disconnect the PV module from the DPI-208 and DPI-480 Microinverter without first discon
-
necting the AC power.
- Only qualified professionals should install and/or replace
Yotta DPI-208 and DPI-480 Microinverters
.
- Perform all electrical installations in accordance with local electrical codes.
- Before installing or using the DPI-208 and DPI-480 Microinverter, please read all instructions and warn-
ing notices in the technical documents and on the DPI-208 and DPI-480 Microinverter system and the
solar array.
- Be aware that the case of the DPI-208 or DPI-480 Microinverter is the heat sink and can reach a tem-
perature of 80°C. To reduce risk of burns, do not touch the case of the DPI-208 and DPI-480 Microinvert-
er.
- Do
NOT
attempt to repair the DPI-208 or DPI-480 Microinverter. If it fails, contact Yotta ENERGY Cus-
tomer Support to obtain an RMA number and start the replacement process. Damaging or opening the
DPI-208 and DPI-480 Microinverter will
void the warranty
.
-
Caution!
Unlike other Yotta microinverters, DPI-208 and DPI-480 do not provide a ground connection
through the AC connector. Ensure the microinveter is grounded, connect the AC then do the DC connec-
tions.
- Please install isolation switching devices on the AC side of the inverter.
-
Caution!– Hot surfaces
- To reduce the risk of burns -
Do not touch
. Risk of electric shock-(a) both AC
and DC voltage source are terminated inside this equipment. Each circuit must be individually discon-
nected before servicing, and (b) When the photovoltaic array is exposed to light, it supplies a DC voltage
to this equipment. Warranty void if cover removed. No user serviceable parts inside. Refer servicing to
qualified service personnel. This inverter has an integral ground-fault detector / interrupter (GFDI). This
Utility-Interactive Inverter contains active anti-islanding protection (IEEE1547) and is tested per FCC/IC.
1.1 Safety Instructions
2
Содержание DPI-208
Страница 1: ...Installation User manual Ver 1 0 September 2022 DPI 208 DPI 480...
Страница 24: ...10 DPI 208 and DPI 480 Accesories 10 1 Wiring Diagram 22...
Страница 25: ...10 DPI 208 and DPI 480 Accesories 10 2 Accesories Summary 23...
Страница 26: ...Yotta DPI 208 and DPI 480 Microinverter Energy Communication Unit Warranty Card Warranty Card...