This integrated system improves safety; maximizes solar energy harvest; increases system reliability, and 

simplifies solar system design, installation, maintenance, and management. In a typical string inverter 

installation, PV modules are connected in series adding the PV panel voltages which can exceed 1000VDC 

at the end of the PV string. This extreme high DC voltage brings a risk of electrical shocks or electrical 

arcs which could cause fire.

Yotta DPI connects PV modules are connected in parallel which does not increase the PV panel voltage. 

DC voltages in the system never exceeds PV panel Voc, which is typically lower than 60Vdc. This low volt-

age is considered “safe to touch” by fire departments and negates the risk of electrical shock, electrical 

arcs and fire hazards

Yotta DPI-208 and DPI-480 maximize PV energy production

2. Yotta DPI-208 and DPI-480 System Introduction

Two PV modules in parallel inside the Yotta DPI-208/480 and share Maximum Peak Power Tracking 

(MPPT) controls, which ensures that the maximum power is produced to the utility grid regardless of the 

performance of the other PV modules in the array. When PV modules in the array are affected by shade, 

dust, orientation, or any situation in which one module underperforms compared with the other units, 

the Yotta DPI-208 and DPI-480 Microinverter ensures top performance from the array by maximizing the 

performance of each module pair within the array.

More reliable than centralized or string inverters

The distributed Yotta DPI-208 and DPI-480 Microinverter system ensures that no single point of system 

failure exists across the PV system. Yotta Microinverters are designed to operate at full power at ambient 

outdoor temperatures of up to 149°F (65°C). The inverter case is designed for outdoor installation and 

complies with the IP67 environmental enclosure rating.

Simple to install

You can install individual PV modules in any combination of module quantity, orientation, type, and 

power class. However, modules connected to the same MPPT channel must have the same electrical 

specifications and be the same power class.

Smart system performance monitoring and analysis

The Yotta Energy Communication Unit (ECU) is installed by simply connecting it to AC power and provid-

ing an Ethernet or Wi-Fi connection to a broadband router or modem. After installing and configurating 

the ECU, the full network of Microinverters automatically reports to the Yotta Energy Monitor and Analysis 

(EMA) web server. The EMA software displays performance trends, informs you of abnormal events, and 

controls system shutdown when it is needed. (See ECU manual for instructions.)

6

Содержание DPI-208

Страница 1: ...Installation User manual Ver 1 0 September 2022 DPI 208 DPI 480...

Страница 2: ...Microinverter to AC bus cable 11 4 4 6 Step 6 Install a AC bus protective end cap at the end of AC bus cable 11 4 4 7 Step 7 Connect DPI 208 and DPI 480 Microinverters to the PV Modules 12 4 4 8 Step...

Страница 3: ...arn ing notices in the technical documents and on the DPI 208 and DPI 480 Microinverter system and the solar array Be aware that the case of the DPI 208 or DPI 480 Microinverter is the heat sink and c...

Страница 4: ...technical for help Changes or modi cations not expressly approved by the party responsible for compliance may void the user s authority to operate the equipment Federal Communication Commission Inter...

Страница 5: ...killed person to enable him or her to perceive risks and to avoid hazards which electricity can create For the purpose of the safety informa tion of this manual a quali ed person is someone who is fam...

Страница 6: ...d DPI 480 Microinverter is used in utility interactive grid tied applications com prised of three key elements Yotta DPI 208 and DPI 480 Microinverter Yotta Energy Communication Unit ECU Yotta Energy...

Страница 7: ...ich one module underperforms compared with the other units the Yotta DPI 208 and DPI 480 Microinverter ensures top performance from the array by maximizing the performance of each module pair within t...

Страница 8: ...family bene ts from an entirely new architecture The components are encapsulated with silicone to reduce stress on the electronics facilitate thermal dissipation enhance waterproof properties and ensu...

Страница 9: ...tself as well as on the PV array Be aware that installation of this equipment includes the risk of electric shock Do not touch any live parts in the system including the PV array when the system has b...

Страница 10: ...tic system which initiates rapid shutdown upon the activation of a system disconnect or activation of another type of emergency system The initiator shall be listed and identi ed as a disconnecting me...

Страница 11: ...dule junction box or any other obstructions B Mount one Microinverter at each of these locations using hardware recommended by your module racking vendor When installing the Microinverter make sure th...

Страница 12: ...k Use the Bus Cable Unlock Tool of AC Bus to split the connectors NOTE AC connector interface should be as shown NOTE Cover any unusued con nectors with bus cable Y CONN caps to protect the connectors...

Страница 13: ...to these lights when connecting the DC cables 4 4 8 Step 8 Complete the DPI 208 and DPI 480 installation map Fill in the Yotta Registration Cards which provide system information and the Installation...

Страница 14: ...espective loca tion on the Yotta DPI 208 and DPI 480 Installation Map Yotta DPI 208 and DPI 480 Microinverter Energy Communication Unit Warranty 4 Yotta DPI 208 and DPI 480 System Installation A The l...

Страница 15: ...e Microinverters they will start to blink green every 10 sec onds 4 Install and setup the ECU according to the instructions in the ECU manual 5 The Yotta DPI 208 and DPI 480 Microinverters will start...

Страница 16: ...a Ground Fault Detector Interrupter GFDI error in the PV system Unless the GFDI error has been cleared the LED will remain red and the ECU will keep reporting the fault After the ground fault error is...

Страница 17: ...ther units is most likely a Microin verter problem To troubleshoot a non operating DPI 208 and DPI 480 Microinverter Follow the steps below in order No need for maintenance Do not attempt to repair th...

Страница 18: ...e rst AC connector in the branch circuit 3 Disconnect the PV module DC wire connectors from the microinverter 4 Remove the Microinverter from the PV array racking C Install a replacement Microinverter...

Страница 19: ...e and current speci cations of your PV module match with those of the Microinverter Please refer to the datasheet or user manual 2 You must match the DC operating voltage range of the PV module with t...

Страница 20: ...torage Temperature Range 40 F to 185 F 40 C to 85 C Dimensions W x H x D 14 9 5 1 8 359mm X 242mm X 46mm Weight 13 lbs 6kg DC Connector Type St ubli MC4 PV ADBP4 S2 ADSP4 S2 Cooling Natural Convection...

Страница 21: ...8 1 DPI 208 and DPI 480 Microinverter Datasheet Note 1 Utility Interconnection Voltage and Frequency Trip Limits and Trip Times 19...

Страница 22: ...9 Wiring Diagram 9 1 DPI 208 and DPI 480 Connected to Delta grids 20 ECU Energy Communication Unit JB Delta Grid Connections 3 Phase Cable no N or GND Black L1 Red L2 Blue L3...

Страница 23: ...ECU Energy Communication Unit JB WYE Grid Connections 3 Phase Cable no N or GND Black L1 Red L2 Blue L3 9 Wiring Diagram 9 2 DPI 208 and DPI 480 Connected to WYE grids 21...

Страница 24: ...10 DPI 208 and DPI 480 Accesories 10 1 Wiring Diagram 22...

Страница 25: ...10 DPI 208 and DPI 480 Accesories 10 2 Accesories Summary 23...

Страница 26: ...Yotta DPI 208 and DPI 480 Microinverter Energy Communication Unit Warranty Card Warranty Card...

Отзывы: