CAUTION
Do not install the unit drain hose side is too high.
Height A should be less than 5 mm.(Fig.8)
Be sure to arrange the drain hose correctly so that it is
leveled lower than the drain hose connecting port of
the indoor unit. (Fig.7)
Fig.7
OK
NO
NO
Arrange the drain hose
lower than this portion.
Drain hose
Fig.8
A
A
Drain hose
B. UNDER CEILING TYPE
Using the installation template, drill holes for
piping and anchor bolts(for holes).(Fig.9)
Installation
template
Wall
Ceilling
Drilling position
for piping
Drilling position
for anchor bolt
200m
900m
Fig.9
1.Drilling for piping
Select piping and drain directions. (Fig.10)
2.Drilling holes for anchor bolts and installing the
anchor bolts
When the directions are selected, drill 80mm and 50mm
or 150mm dia. hole on the wall so that the hole is tilted
downward toward the outdoor for smooth water flow.
(Fig.11)
Install the drain hose at the rear. It should not be
installed on the top or right side.
Fig.10
Rear (Install the drain
hose in the direction.)
Right
CAUTION
Fig.13
Fig.12
Insert the anchor bolts into the drilled holes, and drive
the pins completely into the anchor bolts with a hammer.
(Fig.13)
60 to 70mm
12.7mm
Wall
6mm
Fig.11
Installation Procedure
With a concrete drill, drill four 12.7 mm dia. Holes.
(Fig.12)
19