
Cautions
4
Temperature and Humidity Range
If the air conditioner is used under higher temperature condition than those listed, the built-in protection circuit may operate
to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower
temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.
Do not use this unit for purposes other than cooling, heating, dehumidifying and ventilation of rooms in ordinary dwellings.
The wiring method should be in line with the local wiring standand.
The waste battery should be disposed properly.
The air breaker should be all-pole switch and the distance between it's two contacts should be no less than 3mm.
Cooling
Heating
Indoor temperature
Outdoor temperature
Indoor temperature
Outdoor temperature
max. DB/WB
min. DB/WB
max. DB/WB
min. DB/WB
max. DB/WB
min. DB/WB
max. DB/WB
min. DB/WB
ON-OFF
Inverter
32/23 C
18/14 C
43/26 C
10 C
27 C
15 C
24/18 C
-7 C
32/23 C
18/14 C
43/26 C
-5 C
27 C
15 C
24/18 C
-
15
C
Specifications
The refrigerating circuit is leak-proof.
For
all the models in this manual
, the all-pole
discon-nexion
connection method should be applied in the power supply.
Such means for disconnection must be incorporation in the fixed wiring.
Содержание YFGE18BXEXBH-RX
Страница 2: ......
Страница 7: ...YFGE24BXEXBH RX YFGE18BXEXBH RX YFGE24BXEXBH RX YFGE24BXEXBH RX ...
Страница 27: ......
Страница 28: ......