SECTION 1 – GENERAL CHILLER INFORMATION AND SAFETY
FORM 150.67-NM1
ISSUE DATE: 4/28/2017
1
Pressure Systems
The unit contains refrigerant vapor and liquid under pres-
sure, release of which can be a danger and cause injury.
The user should ensure that care is taken during installa-
tion, operation and maintenance to avoid damage to the
pressure system. No attempt should be made to gain ac-
cess to the component parts of the pressure system other
than by suitably trained and qualified personnel.
Electrical
The unit must be grounded. No installation or main-
tenance work should be attempted on the electrical
equipment without first switching power OFF, isolat-
ing and locking-off the power supply. Servicing and
maintenance on live equipment must only be per-
formed by suitably trained and qualified personnel. No
attempt should be made to gain access to the control
panel or electrical enclosures during normal operation
of the unit.
Rotating Parts
Fan guards must be fitted at all times and not removed
unless the power supply has been isolated. If ductwork
is to be fitted, requiring the wire fan guards to be re-
moved, alternative safety measures must be taken to
protect against the risk of injury from rotating fans.
Sharp Edges
The fins on the air-cooled condenser coils have sharp
metal edges. Reasonable care should be taken when
working in contact with the coils to avoid the risk of
minor abrasions and lacerations. The use of gloves is
recommended.
Frame rails, brakes, and other components may also
have sharp edges. Reasonable care should be taken
when working in contact with any components to avoid
risk of minor abrasions and lacerations.
Refrigerants and Oils
Refrigerants and oils used in the unit are generally non-
toxic, non-flammable and non-corrosive, and pose no
special safety hazards. Use of gloves and safety glasses
is, however, recommended when working on the unit.
The build up of refrigerant vapor, from a leak for ex-
ample, does pose a risk of asphyxiation in confined or
enclosed spaces and attention should be given to good
ventilation.
High Temperature and Pressure Cleaning
High temperature and pressure cleaning methods
(e.g. steam cleaning) should not be used on any part
of the pressure system as this may cause operation of
the pressure relief device(s). Detergents and solvents,
which may cause corrosion, should also be avoided.
Emergency Shutdown
In case of emergency, the control panel is fitted with a
Unit Switch to stop the unit in an emergency. When op-
erated, it removes the low voltage 120VAC electrical
supply from the inverter system, thus shutting down
the unit.
Содержание YCAL0019
Страница 4: ...JOHNSON CONTROLS 4 FORM 150 67 NM1 ISSUE DATE 4 28 2017 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 14: ...JOHNSON CONTROLS 14 FORM 150 67 NM1 ISSUE DATE 4 28 2017 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 69: ...69 JOHNSON CONTROLS SECTION 5 TECHNICAL DATA FORM 150 67 NM1 ISSUE DATE 4 28 2017 5 5...
Страница 71: ...71 JOHNSON CONTROLS SECTION 5 TECHNICAL DATA FORM 150 67 NM1 ISSUE DATE 4 28 2017 5 5...
Страница 127: ...127 JOHNSON CONTROLS SECTION 5 TECHNICAL DATA FORM 150 67 NM1 ISSUE DATE 4 28 2017 5 5 DIMENSIONS YCAL0052 SI CONT D...
Страница 129: ...129 JOHNSON CONTROLS SECTION 5 TECHNICAL DATA FORM 150 67 NM1 ISSUE DATE 4 28 2017 5 5 DIMENSIONS YCAL0056 SI CONT D...
Страница 191: ...191 JOHNSON CONTROLS SECTION 8 UNIT OPERATION FORM 150 67 NM1 ISSUE DATE 4 28 2017 8 Figure 48 WIRING LD11799A...
Страница 202: ...JOHNSON CONTROLS 202 FORM 150 67 NM1 ISSUE DATE 4 28 2017 SECTION 8 UNIT OPERATION THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 229: ...229 JOHNSON CONTROLS SECTION 10 MAINTENANCE FORM 150 67 NM1 ISSUE DATE 4 28 2017 NOTES...