122
YORK INTERNATIONAL
CLOCK KEYS
GENERAL
The CLOCK is an internal system feature that allows the
microprocessor to continuously monitor the time of the
day. The micro will display the actual time as well as the
day of the week and the date on the control panel dis-
play, if programmed. The internal clock allows the micro-
processor to provide an internal automatic time clock
feature for starting and stopping the chiller for each indi-
vidual day of the week. Also provided is a HOLIDAY fea-
ture which allows special start / stop programming for
designated holidays.
The internal clock and schedule programming eliminates
the need for an external time clock. Automatic chiller
start and stop will occur according to the programmed
schedule.
If the user decides not to utilize the schedule feature,
the SET SCHEDULE / HOLIDAY can be programmed to
run the chiller on demand as long as the UNIT and SYS
switches are ON.
Typical display messages will be shown which apply to
each key.
PROGRAMMING THE DAY, SET TIME & THE DATE
Set Time
A message showing the day, time and date will be dis-
played when the SET TIME key is pressed.
When the display appears, the cursor will be below the
first digit of the time. Press the ADVANCE DAY key until
the proper day appears. Key in the time (hour and minute).
Be sure to key in a “0” before the other digits for times
before 10 o’clock. i.e. 08:31.
After the time is keyed in, the cursor will advance to the
AM/PM designation. To reprogram, press the AM/PM key.
When the key is pressed, the display will change to the
opposite time period.
NOTE: The AM/PM key can be pressed once. If an er-
ror is made, press the CANCEL key and begin
again.
T O D A Y
I S
M O N
1 1 : 1 2 A M
1 9
F E B
9 7
FIG. 29 – CLOCK KEYS
28164A
SET
TIME
CLOCK
KEYS
Содержание Millennium YCAS 316
Страница 11: ...FORM 201 10 NM1 11 YORK INTERNATIONAL YCAS 140 246 DIMENSIONS English LD01444 LD01446...
Страница 13: ...FORM 201 10 NM1 13 YORK INTERNATIONAL YCAS 140 246 DIMENSIONS SI LD01440 LD01442...
Страница 15: ...FORM 201 10 NM1 15 YORK INTERNATIONAL YCAS 216X 266X DIMENSIONS English LD01454 LD01454...
Страница 17: ...FORM 201 10 NM1 17 YORK INTERNATIONAL YCAS 216X 266X DIMENSIONS SI LD01450 LD01448...
Страница 33: ...FORM 201 10 NM1 33 YORK INTERNATIONAL 28514A FILTER DRYER LIQUID STOP VALVE...
Страница 37: ...FORM 201 10 NM1 37 YORK INTERNATIONAL LD01285 FIG 3 SCREW CHILLER REFIGERANT FLOW DIAGRAM...
Страница 54: ...54 YORK INTERNATIONAL FIG 9 SYSTEM WIRING YCAS 140 246 CONNECTION DIAGRAM SYSTEM WIRING LD01466 D...
Страница 59: ...FORM 201 10 NM1 59 YORK INTERNATIONAL FIG 11 CONTINUED LD01465 D...
Страница 60: ...60 YORK INTERNATIONAL FIG 12 CONNECTION DIAGRAM WYE DELTA YCAS 140 246 CONNECTION DIAGRAM WYE DELTA LD01458 D...
Страница 61: ...FORM 201 10 NM1 61 YORK INTERNATIONAL FIG 12 CONTINUED LD01458 D...
Страница 69: ...FORM 201 10 NM1 69 YORK INTERNATIONAL FIG 16 CONTINUED LD01206 D...
Страница 71: ...FORM 201 10 NM1 71 YORK INTERNATIONAL FIG 17 CONTINUED LD01202 D...