Standard Specifications
IM 01G05B02-01E 1st Edition
5
Model and Suffix Code
Ultrasonic flowmeter, portable type
Model
Suffix code
Specification
US300PM
·····························
Ultrasonic flowmeter, portable type
Output
-A0 ······················
No current output
-A1 ······················
One current output
-A2 ······················
Two current outputs
Power Supply
Adapter and AC
cable
1 ···················
Japan
2 ···················
USA
3 ···················
Europe
4 ···················
United Kingdom
5 ···················
Australia
6 ···················
South Africa
-2 ···············
Always 2
-N ··········
Always N
Option
/PU1 ····
One binary (pulse or alarm)
output (open-collector) (*1)
/PU2 ····
Two binary (pulse or alarm)
outputs (open-collector) (*1)
/FQ1 ····
Frequency output (open-
collector, 0 to 1kHz)
/DLX ····
Data logging extension
(100,000 values)
/BGT ····
Tag number on nameplate
(in the nameplate label,
maximum 16 characters)
/WTG ···
Wall thickness probe for
general temperature (
–20 to
+60°C /
–4 to +140°F)
/WTH ···
Wall thickness probe for
high temperature (0 to
+200°C / 32 to 392°F)
*1: Option /PU1 and /PU2 are exclusive.
Optional extension cable for portable type
Model
Suffix code
Specification
US300PC ····················
Optional extension cable for portable
type
Length
-A005 ··········
-A010 ··········
-A020 ··········
Cable length 5 m (16 ft)
Cable length 10 m (32 ft)
Cable length 20 m (65 ft)
Data transfer software
Model
Suffix code
Specification
US300SA ····················
Data transfer software (Windows
version) Including connecting kit
(RS232 cable for connection, RS232
adapter 9/25)
Language
-1 ················
English / German version
00 ····
Always 00
Transducers for portable type (*2)
Model
Suffix code
Specification
US300PT
······························
Transducers for portable
type
Usage
-G ·························
General purpose (IP65)
-W ························
Immersible (IP67)
Pipe Size /
Fluid
Temperature
(*3)
BG ·····················
Medium & General
(with 3 m / 9.8 ft cable)
BH ·····················
Medium & High (with 3 m /
9.8 ft cable)
CG ·····················
Large & General
(with 4.4 m / 14.4 ft cable)
CH ·····················
Large & High (with 4.4 m /
14.4 ft cable)
DG ·····················
Very large & General
(with 12 m / 39.4 ft cable)
Mounting fixture
(*4)
-C ···················
Retaining clip type (set of
two clips)
-S ···················
Standard type (set of two
blocks, including ruler
marked length 320 mm,
equivalent to 12.6 in.)
-M ···················
Magnetic type for general
temp.
(
–30 to +100°C / –22 to
+212°F, set of two blocks,
including ruler marked
length 320 mm, equivalent
to 12.6 in.)
-N ···················
None
Fixing chain (*4)
B ·················
For 25 to 1200 mm
(1 to 47 in.)
Fixing chains of 2 m / 6.5 ft
length (2 x 2)
C ·················
For 1200 to 3000 mm (47 to
118 in.)
Fixing chains of 2 m / 6.5 ft
length (5 x 2)
D ·················
For 3000 to 6500 mm (118
to 255 in.)
Fixing chains of 2m / 6.5 ft
length (11 x 2)
N ·················
None
Acoustic couplant
G ··············
General temperature type (
–
30 to +130°C /
–22 to
+266°F)
H ··············
High temperature type (
–30
to +200°C / -22 to +392°F)
N ··············
None
Option
/TTP ······
Transducer tag plate
(maximum 16 characters)
*2: Two sets of transducers are necessary when applying dual
channel/path measurement.
*3: The alphabetic characters in the suffix code represent pipe
sizes and fluid temperature ranges are below.
B: Medium type (25 to 400 mm / 1 to 16 in.)
C: Large type (100 to 2,500 mm / 4 to 98 in.)
D: Very large type (2,000 to 6,500 mm / 78 to 255 in.)
G: General temperature (
–30 to +130°C / –22 to +266°F)
H: High temperature (
–30 to +200°C / –22 to +392°F)
*4: When selecting code
–C or –S for mounting fixture, always
select code B, C, or D for fixing chain. When selecting
code
–M for mounting fixture, fixing chains are optional.
When selecting code
–N for mounting fixture, select also
code N for fixing chain.