background image

Standard Specifications 

IM 01G05B02-01E 1st Edition 

Dust and Water-proof: 

General type: 

IP65 (EN60529) 

Immersible type: IP67 (EN60529) 

Applicable Pipe Sizes (inner diameter): 

Medium type: 25 to 400 mm (1 to 16 inches) 
Lager type: 100 to 2,500 mm (4 to 98 inches) 
Very large type: 2,000 to 6,500 mm (78 to 255 inches) 

(Note) 

Only “6,500 mm” above is the size for outer diameter. 

Fluid Temperature Range: 

General temperature type: 

–30 to +130°C (–22 to +266°F) 

High temperature type: 

–30 to +200°C (–22 to +392°F) 

Note:  Pay attention also to temperature specification of the 

couplant you choose. 

Mounting Fixture Variety and Usage: 

Retaining clip: 

Inserted into the groove on the upper side of 
transducers. Transducers are fixed onto the pipe by 
fixing chains hooked at the retaining clip. 

Mounting fixture standard type: 

Consisted of two metal blocks with a slide-in ruler to 
hold transducers in place and adjust their distance 
easily. Transducers are fixed onto the pipe by fixing 
chains hooked at the mounting fixture. 

Mounting fixture magnetic type: 

Pieces of magnet are attached onto both sides of 
blocks for the “standard type” above. When the pipe 
material is what magnet pulls, transducers are fixed 
onto the pipe by magnetic power eliminating the use 
of fixing chains. If necessary, magnet pieces can be 
easily added for stronger magnetic power. 

 

Optional Extension Cable 

Extends the length of transducer cable when the 
standard length is not enough for the site conditions. 
Select the extension length from 5 m (16 ft), 10 m (32 ft), 
or 20 m (65 ft). 

 

Wall Thickness Probe 

Specified in the option code of US300PM main unit. 
Model codes as accessories also available for 
separate/additional orders (listed later). 

Fluid Temperature Range: 

General temperature type: 

–20 to +60°C (–4 to +140 °F) 

High temperature type: 0 to +200°C (32 to 392°F) 

Measuring Performance: 

Measuring range: 1.0 to 200 mm (0.04 to 7.8 inches), 
depends on the material 
Resolution: 0.01 mm (0.0004 inch) 

 

Accessories 

Standard Accessories for US300PM Main Unit: 

Transportation case, Measuring tape, and Built-in 
battery set always come with US300PM. 

Fixing Hardware, Couplant, etc: 

Specified in the suffix code of US300FT transducers. 
Model codes as accessories also available for 
separate/additional orders (listed later). 

Power Supply Adapter and AC cable: 

The power supply adapter and the AC cable are 
dedicated to US300PM. Please do not use them with 
other devices. 

 

Data Transfer Software 

General: 

The software installed on a personal computer receives 
one or more records of logging data and parameter sets 
stored in US300PM main unit via RS232 
communication port. 
Data can be viewed or graphed on a PC monitor, or 
exported as a text file. 
This software works while US300PM is off-line (not 
measuring flow) where current output goes down to 
zero. 

Function: 

Displaying Parameter Record: 

Display parameter record of selected measuring data 
set. 

Displaying Measured Data in Table: 

Display measured data of selected measuring data 
set in table format. 

Displaying Data in Graph: 

Display measured data of selected measuring data 
set in graphic format. Marker type and color for each 
line of values selectable. Scales for time-axis and 
value-axis can be changed from default condition of 
automatic scaling. Graph printing function embedded. 

Displaying Statistical Data: 

Display statistical data of the measurement. Total 
data points, minimum, maximum, average and 
standard deviation of the measured data can be 
shown. Data range for statistical processing can be 
designated if necessary. 

Exporting Text File: 

Parameter record and measured data can be 
exported to a text file. Options for exporting items or 
their formats are available. 

Entering Remarks: 

User’s remarks for each measured data can be 
entered and edited in the transferred data file on a 
personal computer. Remarks can be displayed in the 
main window of the software. 

Display Language: 

English, German 
(Note) Help is available only in English. 

Operating Environment: 

Personal Computer: 

Microsoft

®

 Windows

®

 hardware compatible, one or 

more RS232 port 

Operating System: 

Microsoft

®

 Windows

®

 98, ME, NT, 2000, XP 

Standard Accessories: 

RS232 cable, RS232 adapter 9/25 

*  Microsoft

®

 and Windows

®

 are registered trademarks 

of Microsoft Corporation in the United States and/or 
other countries. 

Содержание US300PM

Страница 1: ...Scope of Delivery page 7 and the section 3 4 2 Rear Panel page 13 Change the figure of a nameplate to as below Addition to the section 2 3 General Precautions page 8 The power supply adapter and the AC cable are dedicated to US300PM Please do not use them with other devices Do not disassemble or remodel Addition to the chapter 4 Getting Started page 15 Attention The current outputs may temporarily...

Страница 2: ...oldstart Pressing these two keys simultaneously and after acknowledging the display of main menu release i BRK first and then ii C This will initialize the instrument Most parameters and settings are reset to the factory default values The same procedure is required as above when the DELETE MEAS VAL display appears Addition to the section 5 6 Selection of the Sound Path Factor page 30 When you sel...

Страница 3: ... When you select auto the setting for the sound path factor will be automatic Sound Path auto USER Changes to the section 11 6 Charging the Battery page 77 Change The chargeable NiCd batteries guarantee an operating time of approximately 14 hours to The chargeable NiCd batteries guarantee an operating time of approximately 10 hours at room temperature 20 C 68 F with full charge Addition to the sec...

Страница 4: ...or two optional Range 4 to 20 mA Load resistance 0 to 500 Ω Note The current outputs may temporarily turn unstable during the switch on sequence and parameter display setting mode Take care of your process not to be affected by this behavior Frequency Output None standard or one optional Range 0 to 1 kHz Contact type Open collector 24 V 4 mA Binary Output None standard one or two optional Contact ...

Страница 5: ...ng for printer Decimal point character Data delimiter Communication interface RS232 Communication port D sub 9 pin male Time Programmable Measurement Function Automatic start stop of the measurement without human operation using internal clock for specific systems Can be used with current output binary output data logging function and or communication function for recording the measurement Site Pa...

Страница 6: ... and Built in battery set always come with US300PM Fixing Hardware Couplant etc Specified in the suffix code of US300FT transducers Model codes as accessories also available for separate additional orders listed later Power Supply Adapter and AC cable The power supply adapter and the AC cable are dedicated to US300PM Please do not use them with other devices Data Transfer Software General The soft...

Страница 7: ...its of Measurement Volume flow Flow velocity Mass flow Totalizers Sound velocity Volume Mass m3 h m s g s m3 g m s m3 min inch s t h l kg m3 s kg h gal t l h kg min l min l s USgph USgpm USgps bbl d bbl h bbl m 1 gallon US 3 78 l 1 barrel 42 gallons 158 76 l ...

Страница 8: ...sible IP67 Pipe Size Fluid Temperature 3 BG Medium General with 3 m 9 8 ft cable BH Medium High with 3 m 9 8 ft cable CG Large General with 4 4 m 14 4 ft cable CH Large High with 4 4 m 14 4 ft cable DG Very large General with 12 m 39 4 ft cable Mounting fixture 4 C Retaining clip type set of two clips S Standard type set of two blocks including ruler marked length 320 mm equivalent to 12 6 in M Ma...

Страница 9: ...et of two extensible chains 1 m 3 2 ft length equal to 300 mm 11 8 in diameter USPA053 Mounting fixture short ruler type for transducers medium pipe size type temperature range 30 to 200 C 22 to 392 F set of two blocks with 120 mm 4 7 in ruler USPA054 Mounting fixture standard type for transducers medium pipe size type temperature range 30 to 200 C 22 to 392 F set of two blocks with 320 mm 12 6 in...

Страница 10: ...on cable US300PC A Length Weight Transducer X m inch Y m inch X Y m inch Weight kg lb US300PT B 2 0 78 7 1 0 39 4 3 0 118 1 0 6 1 32 US300PT C 2 0 78 7 2 4 94 5 4 4 173 2 1 2 2 65 US300PT D 5 0 196 9 7 0 275 6 12 0 472 4 2 2 4 85 Length Weight Optional extension cable L m inch Weight kg lb US300PC A005 5 0 196 9 0 4 0 88 US300PC A010 10 0 393 7 0 6 1 32 US300PC A020 20 0 787 4 1 6 3 53 ...

Страница 11: ...mperature 20 to 60 C 4 to 140 F option WTG or model USPA301 Unit mm inch Wall thickness probe for high temperature 0 to 200 C 32 to 392 F option WTH or model USPA302 Length Weight Wall thickness probe L m inch Weight kg lb WTG or USPA301 1 5 59 1 0 17 0 37 WTH or USPA302 1 5 59 1 0 24 0 53 ...