Manual Change for IM 01G05B02-01E 1st Edition : No.15-021-E Nov. 24 2015-00
Addition to the section “6.1 Selection of the Physical Quantity and of the Unit of Measurement” (page 37) :
Attention!
In case of mass flow, select
“Other Medium” as a measured fluid. When “Other Medium”
has been selected, US300PM requests to enter the density which is used to calculate
mass flow.
Changes to the section
“7.2 Flow Totalizers” (page 41) :
Two of the key operations have been changed as below.
To reset the two flow totalizers to zero:
Press key
ON
O
three times when a totalizer is displayed.
To deactivate flow totalizing:
Press key
OFF
O
three times when a totalizer is displayed.
Addition to the section “11.2 Settings for Dialogues and Menus” (page 72) :
“Sound Path” setting appears next to “Meas.Point No.” and you can select “auto” or “user”. When you select
“auto”, the setting for the sound path factor will be automatic.
Sound Path
auto >USER<
Changes
to the section “11.6 Charging the Battery” (page 77) :
Change
“The chargeable NiCd-batteries guarantee an operating time of approximately 14 hours.”
to
“The chargeable NiCd-batteries guarantee an operating time of approximately 10 hours at room temperature
(20°C / 68°F), with full charge.
”
Addition to the section “15.5 Activation of a Pulse Output” (page 101) :
Maximum pulse output rate is 2 pulse per second (+/-20%).
Set the
“Pulse Value” and the “Pulse Width” so that the actual maximum flow in the pipe is less than half
the displayed value (
“Max – Value”).
Example:
The actual maximum flow 120m
3
/h
Pulse Value = 0.02m
3
Pulse Width = 150ms
INFO: Max
– Value
240.0m
3
/h
Attention!
It is necessary to activate flow totalizers by pressing key
ON
O
to get the actual pulse
output. Refer to the section 7.2 for flow totalizers.
Changes to the chapter
“A Standard Specification” (page 117 to 124) :
Please use the following sheets for this chapter.