4-22
IM 04L51B01-41EN
■ Loading the current settings from the wireless communication module
Click
Load from module
to load the current settings from the wireless communication
module. You can change the refuse radio device list based on the loaded information.
■ To save the refuse radio device list
After setting the refuse radio device list, click
Save configuration
. The refuse radio device
list is saved with the specified file name in the specified folder. By default, the file is saved
with the following file name in the following folder.
• C:\OKI\MH920 Console International\Node_Log\MAC address_BlackList_date and time.
csv
* The MAC address is omitted if the file is saved without a wireless module connected.
■ To Load the refuse radio device list from a configuration file
Click
Load Configuration
to load a configuration file containing the refuse radio device list
and show the content of the file in the Maintenance console window.
4.5.5
Station Number List Window (sub window)
In the Station number list window, register combinations of routers’ short addresses and
station numbers of devices connected to the routers.
How to open this window:
• In the main window, click
Coordinator configuration
. In the coordinator configuration selection
window, click
Module setup
. In the Coordinator configuration window, click the
Station
number setup
tab and then
Station number list
.
You can enable the
Station number list
button by setting the
Specification method of
Station numbers
to List on the Station number setup tab of the Coordinator configuration
window. Click
Station number list
to open a Station number list window.
4.5 Configuring the Coordinator Module