5. BLOCK SETTING
5-4
All Rights Reserved. Copyright © 2006, Rota Yokogawa
IM 01R01B02-01E-E 5th edition October 01, 2020-00
TOTALIZER_UNIT
The totalizer unit is defined from the selected flow unit and determined by order. Table 5.2 and 5.3 show the
available units as defined in the PROFIBUS standard.
Table 5.2 Totalizer units for volumetric flow
Unit Symbol
Unit Description
Unit Code
m³
Cubic meter
1034
m³ normal
Normal cubic meter (0 °C, 1atm = 101325 Pa)
1573
L
Liter
1038
L normal
Normal liter (0 °C, 1 atm = 101325 Pa)
1574
ft³
Cubic foot
1043
ft³ std.
Standard cubic foot
1053
gal
Gallon (U.S.)
1048
bbl
Barrel (U.S. petroleum)
1051
ImpGal
Gallon (Imperial)
1049
m³ std.
Standard cubic meter (20 °C, 1 atm = 101325 Pa)
1575
L std.
Standard liter (20 °C, 1 atm = 101325 Pa)
1576
Table 5.3 Totalizer units for mass flow
Unit Symbol
Unit Description
Unit Code
kg
Kilogram SI
1088
t
Metric ton
1092
lb
Pound (Avoirdupois)
1094
LTon
Long ton
1096
STon
Short ton
1095
g
Gram
1089
TOTALIZER
Indicates the totalized volumetric or mass flow depending on the selected flow unit.
Changing the flow unit will cause a reset of the actual totalizer value.
The parameter TOTALIZER
can not be used for cyclic communication on AI Function Block.