Outline of Each Section
Panel switch
Status indicator
(LED-RED)
Data display
(7seg LED)
1
2
4
5
6
7
8
3
9
10
11
12
14
13
1
kWh (Integration)
Light on when data on Display Section is inte-
grated power [kWh].
2
Wh (Optional Integration)
Light on when data on Display Section is optional
integrated power [Wh].
3
W (Power)
Light on when data on Display Section is power
momentary value [W].
4
V (Voltage)
Light on when data on Display Section is voltage
momentary value [V].
5
A (Current)
Light on when data on Display Section is current
momentary value [A].
6
cos
φ
Light on when data on Display Section is power
factor momentary value [cos
φ
].
7
X 10
3
Light on when data value on Display Section is kilo
unit. And light on when integrated power value is
mega unit.
8
X 10
6
Light on when data value on Display Section is
mega unit.
9
COMM
Light on during communication (RS-485 commu-
nication) is made.
10 Display Section
Display measured value data, preset parameter
symbol, set value data, adjustment parameter
symbol, adjustment data and the like.
(1) Measurement items: integrated power, op-
tional integrated power, power momentary
value voltage momentary value, current mo-
mentary value, power factor momentary value
(2) Setting items: RS-485 station number, data
transmission rate, lower limit of input range,
upper limit of input range, PT ratio, CT ratio, in-
tegrating low cut power, integrating pulse unit
(fixed point part, exponent), integrating pulse
ON pulse duration
(3) Adjustment items: power momentary value in-
put zero, power momentary value input
span,voltage momentary value input zero, volt-
age momentary input span, current momen-
tary value input zero, current momentary value
input span, power momentary value input
zero, power momentary value input span
11
SET/ENT
SET/ENT Switch
This switch is used for changing over displays of
screens and items. It is also used for registration of
set values and adjusted values. Pressing the
switch for 3 seconds or more changes over the dis-
plays for measured value, parameter setting, or
input/output adjusting.
12
Range Switch
This switch is used for changing over display of
phases. It is also used for shifting digit position and
decimal position of set values on parameter setting
display.
13
Figure UP switch
This switch is used for the followings:
1. Increase the set value on parameter setting
display.
2. Display the maximum value of voltage or cur-
rent.
3. Increase the adjusted value at input/output ad-
justment. I
14
Figure DOWN switch
This switch is used for the followings:
1. Parameter decrement at parameter setting.
2.
Display the minimum value of voltage or current
3.
Decrease the adjusted value at input/output adjust-
ment