IM 77C01U01-01E

1st Edition : Dec. 26, 2000-00

Wiring Diagrams

5

55

6

56

7

57

8

58

60

11

12

13

14

15

18

40

20

2

52

4

54

+

9

59

10

31

32

33

34

35

36

16

37

17

38

39

19

1

51

3

53

Power Side

Load Side

L

N

Power Supply

Communication

Short Terminating

Voltage 

or 

Contact

A

B
C (Shild)

PT

CT

K

L

P1

P2

1S

1L

+

1

2

Receiver 
Device

(S)

(R)

5

55

6

56

7

57

8

58

60

2

52

4

54

9

59

10

1

51

3

53

1

N

2

PT

CT

CT

K

L

K

L

1S

1L

2S

2L

P1

P2

P0

11

12

13

14

15

18

40

20

+

31

32

33

34

35

36

16

37

17

38

39

19

Power Side

Load Side

L

N

Power Supply

Communication

Short Terminating

Voltage 

or 

Contact

A

B
C (Shild)

+

Receiver 
Device

(T)

(S)

(R)

1 phase 2 wire system

1 phase 3 wire system

5

55

6

56

7

57

8

58

60

2

52

4

54

9

59

10

1

51

3

53

PT

CT

CT

1S

1L

3S

3L

P1

P3

P2

K

L

K

L

1

N

2

11

12

13

14

15

18

40

20

+

31

32

33

34

35

36

16

37

17

38

39

19

Power Side

Load Side

L

N

Power Supply

Communication

Short Terminating

Voltage 

or 

Contact

A

B
C (Shild)

+

Receiver 
Device

(T)

(S)

(R)

7

57

8

58

2

52

4

54

P1

P3

P2

9

10

1

51

3

53

5

55

6

56

PT

CT

CT

CT

K

L

K

L

K

L

1S

1L

2S

2L

3S

3L

P0

60

59

N

3

11

12

13

14

15

18

40

20

+

31

32

33

34

35

36

16

37

17

38

39

19

Power Side

Load Side

L

N

Power Supply

Communication

Short Terminating

Voltage 

or 

Contact

A

B
C (Shild)

+

Receiver 
Device

2

1

(T)

(S)

(R)

3 phase 3 wire system

3 phase 4 wire system

CAUTION

The following caution for safety should be taken for handling of product.  We are not respon-
sible for damage incurred by use contrary to caution.

The following items should be checked before turning power on.  Use of product
ignoring specifications may cause over heating or burning.
(a) Voltage of power supply and input value applied to the product should meet with

required specifications.

(b) External wiring to terminals should be connected correctly.

 (See precding Article 4)

When take off wiring from the product, check to see primary side of CT, PT and power
supply is in OFF status.  If CT secondary side is in OPEN status during operation, be
careful for danger of high voltage.

Do not use the product in such dangerous places where exist inflammable and explo-
sive gas or steam.

Содержание Powercert UZ005

Страница 1: ...User s Manual IM 77C01U01 01E Model UZ005 Power Monitor IM 77C01U01 01E 1st Edition ...

Страница 2: ...Blank Page ...

Страница 3: ...to connect the grounding 3 Turn off the product before installation and wiring 4 Use the power supply within specifications 5 Observe the following instructions for correct installation Recommended panel thickness is 1 to 10mm Install the product horizontally Install the product using attached fixture from the backside of the product Turn the screw only up to 180 after the screw touches the mounti...

Страница 4: ...t 1 2 110V can also be used at 120V input Note 3 Rated input 5 6 440V is the specs only for 1 phase 2 wire system and 3 phase 3 wire system Note 4 Rated input A to F is the specs for only 3 phase 4 wire system Rated input voltage indicates phase voltage A B 64V C D 127V E F 227V indicate 110V 3 220V 3 480V 3 respectively In case of 440V 3 input it can be used at E F 227V of rated input Note 5 Spec...

Страница 5: ...c 26 2000 00 External Dimensions and Panel Cutout Dimensions External Dimensions 96 90 8 90 8 96 11 100 30 Fixturs 91 8 112 Fixturs Panel thickness 1 to10 mm Terminal Cover Panel Cut Dimension Min 130 Min 117 92 0 8 0 92 0 8 0 Unit mm ...

Страница 6: ... to overtighten them Large bracket top mounting hardware Terminal board Small bracket bottom mounting hardware Panel Insert a screwdriver into the brackets to tighten the screws Direction to insert the product Insert the product into the opening at the front of the panel Terminal Arrangement 40 screw M3 5 1 phase 2 wire system Terminat No 1 2 51 52 3 4 53 54 5 6 55 56 9 59 10 60 31 32 33 34 35 36 ...

Страница 7: ...R 7 57 8 58 2 52 4 54 P1 P3 P2 9 10 1 51 3 53 5 55 6 56 PT CT CT CT K L K L K L 1S 1L 2S 2L 3S 3L P0 60 59 N 3 11 12 13 14 15 18 40 20 31 32 33 34 35 36 16 37 17 38 39 19 Power Side Load Side L N Power Supply Communication Short Terminating Voltage or Contact A B C Shild Receiver Device 2 1 T S R 3 phase 3 wire system 3 phase 4 wire system CAUTION The following caution for safety should be taken f...

Страница 8: ...ms RS 485 station number data transmission rate lower limit of input range upper limit of input range PT ratio CT ratio in tegrating low cut power integrating pulse unit fixed point part exponent integrating pulse ON pulse duration 3 Adjustment items power momentary value in put zero power momentary value input span voltage momentary value input zero volt age momentary input span current momen tar...

Страница 9: ...rated pulse unit characteristic setting 4 Integrated pulse ON width setting 4 RS 485 communication protocol setting 4 RS 485 station number setting 4 RS 485 data baud rate setting 4 LON communication node number setting 4 LON communication integrated power data transmission period setting minute 4 LON communication integrated power data transmission period setting second 4 LON communication power ...

Страница 10: ...nge numeral column at pressing key 5 Change numeral column at pressing and key 6 Fixing numeral value at pressing key 7 Light on and off of setting value 8 If the setting is complete correctly press key If required correcting press any of key key and key then repeat from step 1 7 Example of Communication Connection RS232 C Converter RS232 C Cable Short circuit terminating 33 34 35 33 34 35 36 37 A...

Страница 11: ...0000 MW and the value calculated by the formula below is within above input measuring range list Input range W Primary side input power W PT ratio x CT ratio Rated power factor LEAD 0 5 to 1 to LAG 0 5 Optional integrated control signal Input point 1 point Input signal contact or voltage Contact signal ON signal OFF signal below 200 over 100k Voltage signal 1V DC below 200 4 5 to 25V DC ON signal ...

Страница 12: ...9MW 10MW over Display decimal point 0 to 99999kWh 0 00 to 999 99MWh kWh 103 0 0 to 9999 9MWh kWh 103 0 to 99999kWh kWh 103 Inregrated power data is reset to zero when the data exceed maximunm display value Setting range Rated power 100W 200W 300W 400W 500W 600W 800W 1000W 1500W 2000W 3000W 4000W 5 556 10 6 to 1 000 10 1kWh pulse 6 667 10 6 to 1 000 10 1kWh pulse 1 000 10 5 to 1 000 10 1kWh pulse 1...

Страница 13: ...pair cable Optional integrated power 䊐䊐䊐䊐䊐 Wh w o symbol integer 5 digits Instantanous power 䊐䊐䊐 䊐 W to 䊐䊐䊐䊐 MW w symbol floating decimal point 4 digits minimum resolution 0 1W Voltage r m s value 䊐䊐䊐 䊐 V to 䊐䊐䊐䊐 kV w o symbol floating decimal point 4 digits minimum resolution 0 1V Current r m s value 䊐 䊐䊐䊐 A to 䊐 䊐䊐䊐 kA w o symbol floating decimal point 4 digits minimum resolution 0 001A Voltage ...

Страница 14: ...200 Data format Start bit 1 bit Data bit 8 bits Parity None Stop bit 1 bit Error detect SUM CHECK simply adding 2 bytes Xon Xoff Control None Terminating character designation Yes CR Station number setting Can be set through parameter setting screen Setting range 1 to 31 Communication error disposal If data received is other than command reading is ignored and no disposal be made noise or erroneou...

Отзывы: