IM 04P01B01-01E
12-14
FAIL/Chart End Detection and Output (/F1)
Item
Specifications
FAIL output
Relay output on CPU error
Relay operation
Energized during normal operation and de-energized on CPU error. Non-hold operation.
Chart end detection output Stops recording and outputs a relay signal when the remaining amount of chart paper is approx.
2 cm. Also, turns ON the words CHART END on the display.
Relay operation
The relay is energized when the above conditions are met. Non-hold operation.
Contact rating
250 VAC (50/60 Hz)/3 A, 250 VDC/0.1 A (for resistor load)
Clamped Input Terminal (/H2)
Item
Specifications
Measuring input terminal
Uses clamped input terminals.
Non-Glare Door Glass (/H3)
Item
Specifications
Door glass
Uses a door glass with minimal reflection.
Computation Function (/M1)
Item
Specifications
Number of computation channels
Pen model: 8 channels, dot model: 12 channels
Operation
General arithmetic operations: Four arithmetic operations, square root, absolute, common
logarithm, exponential, power, relational operations (<, ≤ , >, ≥ , =, ≠),
logical operations (AND, OR, NOT, XOR)
Statistical operations (TLOG): Average, max., min., sum, and max. – min. for each interval
Constants
Up to 30 constants can be defined
Range: –9.9999E+29 to –1.0000E–30, 0, 1.0000E–30 to 9.9999E+29
Symbol: K01 to K30
Communication input data Digital data via communication can be used in computations other than statistical computation
(TLOG)
Number of communication input data points: 8 (pen model), 12 (dot model)
Range: –9.9999E+29 to –1.0000E–30, 0, 1.0000E–30 to 9.9999E+29
Symbol: C01 to C12
Remote input
Use remote input status (0/1) in equations
Number of inputs: 5
Symbol: D01 to D05
Computation accuracy
32-bit floating-point computation (excluding TLOG computation)
Computation range
Computed values throughout the computation remains within approx. ±3.4×10
38.
Equation
Defined using up to 120 characters.
Execution interval
Scan interval
TLOG timer
Performs statistical calculation for each interval specified by the timer.
Number of timers
3 (periodic printout timer, timer 1, and timer 2).
Timer 1 and 2 modes
Absolute or relative
Reset
TLOG data can be reset at each interval.
Printout
Printout at each interval is possible.
Trend recording
Recording span
–9999999 to 99999999, decimal place arbitrary.
Unit
Up to 6 characters
Recording methods
Zone recording and partial expanded recording available.
Pen
Measurement channels and computation channels can be assigned arbitrarily to pens.
Dot printing
Trend recording of measurement and computation channels. The fastest dot printing interval is as
follows:
Number of channels being trend recorded
Fastest dot printing interval
6 or less
10 s
7 to 12
15 s
13 to 18
20 s
12.5 Specifications of Optional Functions