1.  Instrument Check

Upon delivery, unpack the instrument carefully and inspect it to ensure that it was not damaged 

during shipment. If damage is found, retain the original packing materials (including the outer 

box) and then immediately notify the carrier and the relevant Yokogawa sales office.

Make sure the model and suffix code on the nameplate match your order and the necessary 

accessories are included.

n

  Model & Suffix Codes

FC800D Non-reagent Type Free Available Chlorine Sensor Unit

Model

Suffix code

Option 

code

Description

FC800D

····························· ·········

Non-reagent Type

 

Free Available Chlorine Sensor Unit

Measurement 

object and 

Range

-F1

-C1

-F2

-F3

·········

·········

·········

·········

Free chlorine 0-1 to 0-3 mg/L

Combined chlorine insensitive version 0-1 to 0-3 mg/L

Free chlorine 0-5 mg/L

Free chlorine 0-10 mg/L

Type

-AB

-AD

-AG

-AJ

·········

·········

·········

·········

General purpose for CE, RCM, China standard

General purpose for CSA

General purpose for KC

General purpose

-NN

·········

Always -NN

-NN ·········

Always -NN

Option

/L02

/L03

/L05

/L10

/L20

/SCT

/U

/V

/CB3

/CD3

/CF3

/TB

/ST

Connection cable for analyzer 2 m 

Connection cable for analyzer 3 m

Connection cable for analyzer 5 m

Connection cable for analyzer 10 m

Connection cable for analyzer 20 m

Stainless steel tag plate

Pipe mounting hardware (SUS)

Integrated mounting plate for analyzer and sensor unit

Conduit adapter G1/2× 3 pcs 

Conduit adapter 1/2NPT × 3 pcs

Conduit adapter M20 × 1.5 × 3 pcs

Terminal Box for connecting automatic wash/cal. valve

Assembled in stanchion

l

 Accessories

Name

Q´ty

Remarks

Polishing powder (Alumina)

1 Bottle

For polishing measurement electrode (K9088PE)

Beads

2

2 bags / 1 Q’ ty (-F□: K9332ZP, -C1: K9332ZJ)

Allen wrench

1

Nominal size : 2 mm

Rubber plug

2

Hole plugs for electrode unit

Содержание FC800D

Страница 1: ...User s Manual FC800D Non reagent Type Free Available Chlorine Sensor Unit Start up and Safety Precautions IM 12F05B10 01EN IM 12F05B10 01EN 2nd Edition...

Страница 2: ...Attached to the product printed manual FLXA402T Liquid Analyzer for Turbidity and Chlorine Installation and Wiring IM 12A01G01 02EN Online manual FLXA402T Liquid Analyzer for Turbidity and Chlorine Op...

Страница 3: ...y and service Yokogawa products and parts are guaranteed free from defects in workmanship and material under normal use and service for a period of typically 12 months from the date of shipment from t...

Страница 4: ...0 u Control of Pollution Caused by the Product This is an explanation for the product based on Control of Pollution caused by Electronic Information Products in the People s Republic of China Pb Hg Cd...

Страница 5: ...ging Repair work should be done at grounded workstations using grounded soldering irons and wrist straps to avoid electrostatic discharge CAUTION The Instrument is packed carefully with shock absorbin...

Страница 6: ...safety symbols are used on the product as well as in this manual WARNING This symbol indicates that an operator must follow the instructions laid out in this manual in order to avoid the risks for th...

Страница 7: ...allation Pollution level shows the level of existing the solid liquid and gas which break electrical isolation Category 2 is applied to normal room environment EMC EN 61326 1 Class A Table 2 For use i...

Страница 8: ...insensitive version 0 1 to 0 3 mg L Free chlorine 0 5 mg L Free chlorine 0 10 mg L Type AB AD AG AJ General purpose for CE RCM China standard General purpose for CSA General purpose for KC General pur...

Страница 9: ...ows for sufficient maintenance space with easy maintenance access allows for drainage For information on FLXA402T read the user s manual Install the FC800D s converter and sensor unit in pipes racks o...

Страница 10: ...y Precautions 10 IM 12F05B10 01EN 2nd Edition June 01 2021 00 273 210 5 Unit mm Maintenance space Maintenance space Needle valve Flow cell Sample intle Rc1 4 2B pipe 60 5 Drain outlet Tube size 15 ID...

Страница 11: ...C 31 C 33 NO S1 42 NC 41 C 43 NO S2 72 NC 71 C 73 NO S4 61 62 mA1 65 66 mA2 81 82 mA3 85 86 mA4 21 22 24 SHLD 63 87 88 SHLD 89 A 91 B 92 GND 93 SHLD 94 Termination 95 L 101 N 102 G 001 52 NC 51 C 53 N...

Страница 12: ...stance 100 ohm or less 2 Connection cable is normally 1 m in length It is available with L02 L03 L05 L10 or L20 depending on the length you need 3 In case of selecting TB Terminal box for connecting a...

Страница 13: ...les of power supply by using stanchion cable rack conduit or vinyl band Unplugged cables are dangerous and may cause an electric shock CAUTION When you open the front cover on the detector and Relay B...

Страница 14: ...2T Installation and Wiring IM 12A01G01 02EN n Wiring the power supply The cable size of terminals is 0 13 to 2 5 mm2 in cross sectional area or AWG 26 to 14 Attached cable gland is for cables finished...

Страница 15: ...e Start a regular measurement Refer to IM 12F05B10 02EN for details 4 Maintenance n Periodic maintenance When you must open the front cover and or glands make sure that the seals are clean and correct...

Страница 16: ...ne 01 2021 00 Revision record June 2021 2nd Edition Revised compliant standards p 4 7 Added a code to Model and Suffix Codes p 8 Mar 2021 1st Edition Newly released Yokogawa Electric Corporation 2 9 3...

Отзывы: