background image

6

IM 12F05B10-01EN 2nd Edition : June 01, 2021-00

n

  Safety, Protection, and Modification of the Product

•  In order to protect the system controlled by the product and the product itself and ensure 

safe operation, observe the safety precautions described in this user’s manual. We assume 

no liability for safety if users fail to observe these instructions when operating the product.

•  If this instrument is used in a manner not specified in this user’s manual, the protection 

provided by this instrument may be impaired.

•  If any protection or safety circuit is required for the system controlled by the product or for 

the product itself, prepare it separately.

•  Be sure to use the spare parts approved by Yokogawa Electric Corporation (hereafter 

simply referred to as YOKOGAWA) when replacing parts or consumables.

•  Modification of the product is strictly prohibited.

•  The following safety symbols are used on the product as well as in this manual.

 WARNING

This symbol indicates that an operator must follow the instructions laid out in this manual in order 

to avoid the risks, for the human body, of injury, electric shock, or fatalities. The manual describes 

what special care the operator must take to avoid such risks.

 CAUTION

This symbol indicates that the operator must refer to the instructions in this manual in order to 

prevent the instrument (hardware) or software from being damaged, or a system failure from 

occurring.

CAUTION

This symbol gives information essential for understanding the operations and functions.

NOTE

This symbol indicates information that complements the present topic.

This symbol indicates Protective Ground Terminal.

n

  Warning and Disclaimer

The product is provided on an “as is” basis. YOKOGAWA shall have neither liability nor 

responsibility to any person or entity with respect to any direct or indirect loss or damage arising 

from using the product or any defect of the product that YOKOGAWA can not predict in advance.

Содержание FC800D

Страница 1: ...User s Manual FC800D Non reagent Type Free Available Chlorine Sensor Unit Start up and Safety Precautions IM 12F05B10 01EN IM 12F05B10 01EN 2nd Edition...

Страница 2: ...Attached to the product printed manual FLXA402T Liquid Analyzer for Turbidity and Chlorine Installation and Wiring IM 12A01G01 02EN Online manual FLXA402T Liquid Analyzer for Turbidity and Chlorine Op...

Страница 3: ...y and service Yokogawa products and parts are guaranteed free from defects in workmanship and material under normal use and service for a period of typically 12 months from the date of shipment from t...

Страница 4: ...0 u Control of Pollution Caused by the Product This is an explanation for the product based on Control of Pollution caused by Electronic Information Products in the People s Republic of China Pb Hg Cd...

Страница 5: ...ging Repair work should be done at grounded workstations using grounded soldering irons and wrist straps to avoid electrostatic discharge CAUTION The Instrument is packed carefully with shock absorbin...

Страница 6: ...safety symbols are used on the product as well as in this manual WARNING This symbol indicates that an operator must follow the instructions laid out in this manual in order to avoid the risks for th...

Страница 7: ...allation Pollution level shows the level of existing the solid liquid and gas which break electrical isolation Category 2 is applied to normal room environment EMC EN 61326 1 Class A Table 2 For use i...

Страница 8: ...insensitive version 0 1 to 0 3 mg L Free chlorine 0 5 mg L Free chlorine 0 10 mg L Type AB AD AG AJ General purpose for CE RCM China standard General purpose for CSA General purpose for KC General pur...

Страница 9: ...ows for sufficient maintenance space with easy maintenance access allows for drainage For information on FLXA402T read the user s manual Install the FC800D s converter and sensor unit in pipes racks o...

Страница 10: ...y Precautions 10 IM 12F05B10 01EN 2nd Edition June 01 2021 00 273 210 5 Unit mm Maintenance space Maintenance space Needle valve Flow cell Sample intle Rc1 4 2B pipe 60 5 Drain outlet Tube size 15 ID...

Страница 11: ...C 31 C 33 NO S1 42 NC 41 C 43 NO S2 72 NC 71 C 73 NO S4 61 62 mA1 65 66 mA2 81 82 mA3 85 86 mA4 21 22 24 SHLD 63 87 88 SHLD 89 A 91 B 92 GND 93 SHLD 94 Termination 95 L 101 N 102 G 001 52 NC 51 C 53 N...

Страница 12: ...stance 100 ohm or less 2 Connection cable is normally 1 m in length It is available with L02 L03 L05 L10 or L20 depending on the length you need 3 In case of selecting TB Terminal box for connecting a...

Страница 13: ...les of power supply by using stanchion cable rack conduit or vinyl band Unplugged cables are dangerous and may cause an electric shock CAUTION When you open the front cover on the detector and Relay B...

Страница 14: ...2T Installation and Wiring IM 12A01G01 02EN n Wiring the power supply The cable size of terminals is 0 13 to 2 5 mm2 in cross sectional area or AWG 26 to 14 Attached cable gland is for cables finished...

Страница 15: ...e Start a regular measurement Refer to IM 12F05B10 02EN for details 4 Maintenance n Periodic maintenance When you must open the front cover and or glands make sure that the seals are clean and correct...

Страница 16: ...ne 01 2021 00 Revision record June 2021 2nd Edition Revised compliant standards p 4 7 Added a code to Model and Suffix Codes p 8 Mar 2021 1st Edition Newly released Yokogawa Electric Corporation 2 9 3...

Отзывы: