Chapter 5 Operating Procedures
5.2
GP-IB interface
5-3
5
5.2
GP-IB interface
The AQ4305 has GP-IB ports , allowing remote control using an external PC.
Table 5-1 shows the interface functions of the GP-IB port.
Table 5-1 GP-IB Port’s Interface Functions
Code Interface
Function
Code Interface
Function
SH0
Send function not provided
AH1
All capabilities of receive function
T0
Talker function not provided
L2
Basic listener listen function
SR0
Service request function not provided
RL1
Full local lockout functions
PP0
Parallel polling function not provided
DC0
Device clear function not provided
DT0
Device trigger function not provided
C0
Controller function not provided
Turn OFF all the power switches of this unit and devices (such as the controller).
Using the GP-IB cable, connect the GP-IB connector on the rear of this unit to another device. Make sure
to tighten the connector-fixing screws firmly.
Set the GP-IB port address of the AQ4305, by the [ADDRESS] switch on the rear panel. The default of port
address is 6.
Local
→
Remote
When a listen address is sent from the controller with REN, ATN set to
“
True,
”
this unit enters
remote status.
In remote status, all panel switches other than the [LOCAL] switch are overridden. Also, the
[REMOTE] LED put on, indicating that this unit is in remote status.
When an LLO (Local Lock Out) message is sent from the controller, this unit enters local lockout
status. In this status, the [LOCAL] switch is disabled and does not return this unit to the local
status even when pressed.
To cancel the local lockout status, set REN to "False" from the controller.
Remote
→
Local
When the [LOCAL] switch is pressed, this unit returns to the local status, allowing input of the
switches on the panel. Also, the [REMOTE] lamp put out. To return this unit to local status, send a
GTL (Go To Local) message or set REN to "False" from the controller.
Table 5-2 shows the GP-IB remote commands corresponding to the switches used in the unit.
Table 5-2 Correspondence between the switches and the remote commands.
Switch
Remote Command
Function
State of switch’s LED
F
The shutter open
Lighting
[OUT]
G
The shutter close
turn off
H
The lamp lighting
Lighting
[LAMP]
J
The light out
turn off
This unit is case-sensitive. Control commands must be upper-case letters.
Connecting/disconnecting the GP-IB cable with the power switch turned ON may cause the AQ4305
to malfuction or fail.
Caution
Содержание AQ4305
Страница 1: ......
Страница 2: ......
Страница 4: ...ii ...
Страница 14: ...CONTENTS xii ...
Страница 20: ...1 4 Warranty Chapter 1 Introduction 1 6 ...
Страница 30: ...3 2 Interface Connection Procedures Chapter 3 Before You Start 3 4 ...
Страница 36: ...4 3 Xyz axes Adjustment Chapter 4 Usage Preparations 4 6 Fig 4 5 The optical output level vs Z axis deviation ...
Страница 40: ...5 2 GP IB interface Chapter 5 Operating Procedures 5 4 ...
Страница 50: ...77 2 External Dimensions Chapter 7 Specifications 7 4 ...