OPTIONAL SPECIFICATIONS
○
: Available – : Not available
Item
Specifications
Applicable Model
Code
General
Submersible
AXW***G AXW***W
Grounding Rings (*1) JIS SUS304 (AISI 304 SS Equivalent), a set of two rings
○
○
GR1
Grounding Rings (*2) SUSF304 (AISI 304 SS Equivalent), a set of two rings with gaskets “B”.
○
○
GR2
For District Heating
and Cooling or
Condensation-proof
Urethane resin potting is applied in the terminal box of a remote flowtube. Select JIS
G1/2 for the electrical connections. 30-meter dedicated signal and excitation cables are
pre-wired and waterproof glands with union joints are attached at factory.
○
–
DHC
User-specified Signal
and Excitation Cable
Length
Available for the submersible type and a model with optional code DHC. The cable
length is limited up to 200 meters combined with an AXFA11 converter. Following “L,”
specify the cable length in three digits as a multiple of 1 meter (e. g., 001, 002, or 005)
for a length up to 5 meters, or as a multiple of 5 meters (i.e., 005, 010, 015, or the like)
for a length of 5 meters or more. If this optional code is not selected, a 30-meter length
cable is attached.
○
○
L***
Mass Unit Setting
The flow rate span, transmission pulse weight, and totalizer display pulse weight can be
set in terms of mass unit.
Specify the density of the process fluid when ordering in addition to the mass flow rate
span, transmission pulse weight (for mass unit), and totalizer display pulse weight (for
mass unit).
When ordering a remote flowtube, parameters for 'Mass Unit Setting' will be set in the
corresponding converter before shipment.
1. Density
a. Available density Numerics:
Specify the numeric within the value of 500 to 2000 kg/m
3
, 4.2 to 16.7 lb/gal, or 31.2
to 124.8 lb/cf. And it can be up to five digits, to a maximum of 32000 ignoring the
decimal point. A fraction is limited to the fourth decimal place.
b. Available density units: kg/m
3
, lb/gal, lb/cf
Example: A water density is about 1000 kg/m
3
. In this case specify “1000kg/m
3
”.
However a density is changed by temperature. Specify the actual density.
(The 1000 kg/m
3
is equivalent to 8.345lb/gal and 62.43lb/cf.)
2. The mass flow rate span, transmission pulse weight, and totalizer display pulse
weight
a. Available density Numerics:
Specify the numeric within the value of 0.0001 to 32000. And it can be up to five
digits, to a maximum of 32000 ignoring the decimal point. A fraction is limited to the
fourth decimal place.
b. Mass Units
Available mass units: t, kg, g, klb, lb
Available time units: /d, /h, /min, /s
Note1: In case of specifying the mass flow span, calculate the volumetric flow span
by the setting density, and specify the available value in the mass flow span.
Note2: In case of transmission pulse weight and totalizer display pulse weight,
specify the mass unit which was specified as the flow unit.
○
○
MU
G3/4 Female
Waterproof Glands
Waterproof glands for G3/4 conduits or flexible tubes are attached to the electrical con-
nections. Available only for JIS G1/2 electric connections.
○
–
EW
Waterproof Glands
Waterproof glands are attached to the electrical connections. Available only for JIS G1/2
electric connections.
○
–
EG
Waterproof Glands
with Union Joints
Waterproof glands with union joints are attached to the electrical connections. Available
only for JIS G1/2 electric connections.
○
–
EU
Stainless Steel Tag
Plate
A pendant tag plate of stainless steel (AISI 304 SS equivalent) is provided in addition to
the standard nameplate with the tag number inscribed on it.
Dimension (Height x Width): Approx. 12.5 (4.92) x 40 (15.7) mm (inch)
○
○
SCT
Direction Change of
Electrical
Connection (*3)
+90 degrees rotated terminal box to change the direction of the electrical connection.
○
○
RA
+180 degrees rotated terminal box to change the direction of the electrical connection.
○
○
RB
–90 degrees rotated terminal box to change the direction of the electrical connection.
○
○
RC
Material Certificate
Material certificates are provided for pipe, electrodes, flanges, and also optional ground-
ing rings when specified.
○
○
M01
*1: This is not available for models with process connection JIS F12 (JIS 75M) of sizes 1100 mm (44 in.) to 1800 mm (72 in.). Refer to the section
on “Mounting Procedures” on necessary gaskets.
*2: This is available only for models with process connection JIS F12 (JIS 75M) of sizes 1100 mm (44 in.) to 1800 mm (72 in.). Refer to the section
on “Mounting Procedures” on necessary gaskets.
*3: Refer to the image below.
Standard
+90 degree rotation
+180 degree rotation
–90 degree rotation
Optional Code RA
Optional Code RB
Optional Code RC
Electrical
Connection
Electrical
Connection
Содержание Admag AXW
Страница 1: ...User s Manual AXW Magnetic Flowmeter Remote Flowtube IM 01E25D11 01EN IM 01E25D11 01EN 2nd Edition...
Страница 7: ...Blank Page...
Страница 9: ...Blank Page...
Страница 19: ...Blank Page...
Страница 25: ...Blank Page...
Страница 31: ...Blank Page...
Страница 51: ...Blank Page...