<6. OUTLINE>
6-4
IM 01E25D11-01EN
For Process Connection JIS F12 (JIS 75M)
Model
Suffix Code
Description
Available Size / Model
AXW500
Size 500 mm (20 in.) Remote Flowtube
AXW600
Size 600 mm (24 in.) Remote Flowtube
AXW700
Size 700 mm (28 in.) Remote Flowtube
AXW800
Size 800 mm (32 in.) Remote Flowtube
AXW900
Size 900 mm (36 in.) Remote Flowtube
AXW10L
Size 1000 mm (40 in.) Remote Flowtube
AXW11L
Size 1100 mm (44 in.) Remote Flowtube
AXW12L
Size 1200 mm (48 in.) Remote Flowtube
AXW13L
Size 1350 mm (54 in.) Remote Flowtube
AXW15L
Size 1500 mm (60 in.) Remote Flowtube
AXW16L
Size 1600 mm (64 in.) Remote Flowtube
AXW18L
Size 1800 mm (72 in.) Remote Flowtube
Use
G
General-purpose type
W
Submersible type
Converter
-N
Remote Flowtube for Combined Use with
AXFA11
Power Supply
N
Remote Flowtube
Lining (*1)
U
Polyurethane Rubber
Electrode Material (*1)
L
JIS SUS316L (AISI 316L SS Equivalent)
H
Hastelloy C276 Equivalent
Electrode Structure
1
Non-replaceable
Grounding Structure (*2)
N
None (*3), available as optional feature
(GR1 or GR2)
Process Connection
-CG1
JIS F12 (JIS 75M) Flange (Carbon Steel)
Lay Length
N
Standard
Electrical Connection
-0
JIS G1/2 female
-2
ANSI 1/2 NPT female
Not available for Submersible type
-4
ISO M20 x 1.5 female
Not available for Submersible type
Indicator
N
None
Calibration
B
Standard
Optional Specifications
/
Optional code
*1:
Users must consider the characteristics of selected wetted parts material and influence of process fluids. The use of inappropriate materials
can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the
instrument itself can be damaged and that fragments from the instrument can contaminate the user’s process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-
temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.
*2: Select optional grounding rings (code GR1 or GR2) if necessary. For example, grounding rings are necessary for plastic piping.
The code GR1 is optional only for sizes 500 mm (20 in.) to 1000 mm (40 in.).
The code GR2 is optional only for sizes 1100 mm (44 in.) to 1800 mm (72 in.).
*3: “None” is applicable only for metal piping and wiring for grounding will be necessary so that the electric potentials between flowtube and piping
flange should be the same.