Block Alarm status is shown by this parameter.
Valid range is bit 0: Discrete alm, bit7: Block alarm
(only bit 0 and bit 7 are effective).
Initial value is
Current: 0, Unacknowledged: 0, Unreported: 0,
Disable: 0X0000 (all alarms are enable).
Selects whether or not the adhesion diagnostic function will be
carried out. (If the judgment value for Level 3 exceeds, a warning
is displayed; and if the value for level 4 exceeds, an alarm is
displayed. Valid range is
1: No, 2: Yes
This parameter is used in order to set the resistance value for
judgment of Level 1. Valid range is 0.0 to 100.00 M Ohm
This parameter is used in order to set the resistance value for
judgment of Level 2.Valid range is 0.0 to 100.00 M Ohm
This parameter is used in order to set the resistance value for
judgment of Level 3.Valid range is 0.0 to 100.00 M Ohm
This parameter is used in order to set the resistance value for
judgment of Level 4.Valid range is 0.0 to 100.00 M Ohm
This parameter displays the value measured using the adhesion
diagnostic function. Valid range is 0.0 to 1000.00 M Ohm
85 2085
ALARM_SUM
86 2086
ADHESION_CHECK
1:No
O/S
87 2087
ADHESION_LEVEL1
0.10
O/S
88 2088
ADHESION_LEVEL2
0.50
O/S
89 2089
ADHESION_LEVEL3
1.00
O/S
90 2090
ADHESION_LEVEL4
3.00
O/S
91 2091
-
ADH_MEASURE_
VALUE