Precautions for Safe Use

When operating the instrument, be sure to observe the cautionary notes given below 
to ensure correct and safe use of the instrument. If you use the instrument in any way 
other than as instructed in this manual, the instrument’s protective measures may be 
impaired. YOKOGAWA is by no means liable for any damage resulting from use of the 
instrument in contradiction to these cautionary notes.

  The following safety symbols are used on the instrument and in this manual: 

Danger!  Handle with Care.
This symbol indicates that the operator must refer to an explanation in 
the User’s Manual in order to avoid risk of injury or death of personnel 
or damage to the instrument.

This symbol indicates alternating current (AC).

This symbol indicates direct current (DC).

This symbol indicates a fuse.

This symbol indicates a grounding line.

Indicates a hazard that may result in the loss of life 
or serious injury of the user unless the described 
instruction is abided by.

Indicates a hazard that may result in an injury to the 
user and/or physical damage to the product or other 
equipment unless the described instruction is abided 
by.

 Measurement

· 

This tester is designed for measurement of light electrical circuits. For safe 

use, do not use this instrument for the circuit exceeding 250 V (including 

power lines). Such strong electrical circuits may contain a surge voltage, 

which is several times stronger than that of circuit voltage, thus creating a 

very dangerous situation.

· 

Do not touch the I/O terminals during the measurement of voltage because a 

high voltage may be generated on the measurement leads.

 Measurement leads

· Use the lead supplied by Yokogawa for the instrument concerned.

· Do not use a deteriorated or damaged leads.

· Check test the leads continuity.

· Do not attach/detach the lead to/from the instrument prior to releasing the 

leads from the measured object.

 Protection

· If there are any cracks or other damage in the case because of being 

dropped or struck, the instrument may not be safely insulated. Do not use the 

instrument before any remedial measures are taken.

 Battery/Fuse Replacement

· Prior to detaching the cover for replacing the battery or fuse, release the 

measurement leads from the measured object and turn off the switch.

 Operating Environment

· Do not operate the instrument in a flammable or explosive atmosphere.

· Do not use the instrument when there is condensation on it.

· Do not operate the instrument with wet hands.

 Disassembly

· Disassemblement of the instrument should be conducted only by our service 

engineers.

WARNING

WARNING

CAUTION

 To avoid the risk of injury to personnel including electrical shock or even fatalities, 

carefully observe and follow the warnings listed below.

Содержание 320110

Страница 1: ...User s Manual Model 320110 Circuit Tester IM 3201 E 13th Edition July 2014 KP...

Страница 2: ...Thank you for purchasing this Model 320110 Circuit Tester To fully exploit and properly operate the instrument read this manual carefully prior to using the product...

Страница 3: ...s instrument for the circuit exceeding 250 V including power lines Such strong electrical circuits may contain a surge voltage which is several times stronger than that of circuit voltage thus creatin...

Страница 4: ...2 All rights are reserved by Yokogawa No one is allowed to make copies of reprint any part or all the contents of this instruction manual without permission from Yokogawa 3 If any questions arise or e...

Страница 5: ...requency Output Level 8 3 6 Resistance Measurement 8 3 7 Checking Battery Amount and Battery Replacement 9 3 8 Circuit Diagram Parts List 10 4 Use of Accessories Additional Specifications 11 4 1 Model...

Страница 6: ...iv IM 3201 E...

Страница 7: ...a tester without amplifier It can also be used as an electronic voltmeter 3 Results of the measurement with 320110 are highly accurate with 2 for DC or 3 for AC The scale has a built in mirror 105 mil...

Страница 8: ...ointer 3 Meter Cover 6 Polarity Select Switch 12 Case 14 Bottom Case Fixing Screw 13 Rubber Leg 4 Cover Fixing Screw 5 Zero Adjust Screw 7 Zero ohm Adjust Knob 8 Measuring Range Select Switch 9 Common...

Страница 9: ...resistance measurement it is turned to DC AC This switch has a 3 contact switch to make deflecting angles of the pointer wider to clarify the polarity selection Center Position When the switch is rest...

Страница 10: ...g Screw When replacing batteries remove this screw to open the back cover 15 Measuring Probe This instrument provides two lead wires i e one black and one red The clip adaptor can be used conveniently...

Страница 11: ...burned out Checking Method Set the measuring range select switch to range The fuse operates normally if the pointer points at zero when shorting the V A terminal The pointer does not deflect when the...

Страница 12: ...ch positioning are the same as in the case of the DC current measurement described above 2 Set the measuring range select switch to a desired position on the DC V range Check polarity and connect the...

Страница 13: ...es follow instructions described in the paragraph AC Voltage Measurement 7 To the OUTPUT terminal a 0 2 F capacitor 400 W V is internally provided in series so that the DC component is impeded and onl...

Страница 14: ...ing the resistance in the circuit of equipment the power source to the equipment must be disconnected For the measurement of a circuit which includes capacitors the charged electricity must be dischar...

Страница 15: ...larity noted on the battery holder case 5 Current for each measuring range is as follows at zero position of resistance scale 1 range approximately 150 mA 100 range approximately 1 5 mA 10 k range app...

Страница 16: ...9 M F R13 RG08V3C 18 M F R14 RG08V3C 90 M F R15 RG08V3C 9 M F R16 RG08V3C 1 8 M F R17 RD1 2PX 900 k F R18 RD1 4PX 180 k F R19 RD1 4PX 90 k F R20 RD1 4PX 11 3 k F R21 RD1 4PX 10 k F R22 RD1 4PX 10 k F...

Страница 17: ...air of gloves e g rubber gloves to ensure safety Avoid measuring high voltage on the power line to prevent possible hazards 1 This probe is intended to be used in the adjustment of high voltage electr...

Страница 18: ...20510 Clip On Current Transformer Order Discontinued Item black red Fig 4 3 Clip On Current Transformer 1 By use of this transformer currents to the commercial frequencies can be measured without open...

Страница 19: ...ay indicate the full scale value correctly 2 Set the measuring range select switch to the AC 120 V range Apply AC 120 V and turn the semifixed resistor VR2 so that the pointer may indicate the full sc...

Страница 20: ...f full scale value Input Impedance 10 k V The tolerance for the low frequency output has been expressed as a percentage of the value obtained by converting the maximum scale value dB to a voltage The...

Страница 21: ...lowable Input Voltage DC 15 kV Model 320410 12A DC Shunt Order Discontinued Item Rating Current DC 12 A Rated Voltage Drop 220 mV Accuracy 3 of rating when connected to the tester 320110 Model 320510...

Страница 22: ...16 IM 3201 E MEMO...

Страница 23: ......

Страница 24: ......

Отзывы: