background image

Installation Manual

www.bticino.com

Btdin with Netatmo

RA00180AD-04/22-PC

Содержание FC80AC

Страница 1: ...Installation Manual www bticino com Btdin with Netatmo RA00180AD 04 22 PC ...

Страница 2: ...Btdin with Netatmo Installation Manual ...

Страница 3: ... devices 8 Add a wired device 11 Reset the Wi Fi and Apple HomeKit 13 Reset to the factory settings 13 Use the App 15 Compatibility with civil series 16 Add a wireless scenario control 18 Associate a wireless light control to one or more modular wired devices 22 Dissociate a wireless control from the wired devices 28 ...

Страница 4: ...s and functions shown in this manual The Living Now with Netatmo series was used as an example for the graphic representation of the civil series devices The functions described are valid for all the with Netatmo civil series It is possible to add other functions e g heating management through integration with other devices of the with Netatmo offer e g Smarther with Netatmo The products and featu...

Страница 5: ...0CC suitable for controlling single phase Smart DIN gateway FC80GT Smart DIN FC80CC contactor suitable for controlling single phase Measurement toroid Connected DIN load management module F80GCS L N DIN smart relay for light F20T60A Box Measurement toroid Relè smart FC80RC Equipped with contacts for control with remote buttons N L 2 C1 C2 N 1 FC80AC AUTO I O OFF ON Contactor smart FC80AC with cont...

Страница 6: ...anual Check that the LEDs of all the devices turn on red steady with the exception of the gateway LED which remains off ON 2 Reconnect the power using the general switch 2 N L 2 C1 C2 N 1 FC80AC AUTO I O OFF ON COIL F20T60A FC80GCS COIL ...

Страница 7: ... to associate all the devices and take advantage of the connected functions of your system Note smart contactors will be powered by default After installing the smart electric system it will be possible to control lights and loads without further set up needed ...

Страница 8: ...ait for 1 minute OFF 1 2 ON 3 4 Perform the pairing procedure shown below within 15 minutes of powering up the system Otherwise repeat the operation from the beginning 3 Reconnect the power using the general switch 4 Wait 1 minute for correct system startup N L 2 C1 C2 N 1 FC80AC AUTO I O OFF ON COIL F20T60A FC80GCS COIL ...

Страница 9: ... Gateway until the LED turns green Note the LEDs may take up to 15 minutes to turn from red to green After this time the procedure will end automatically Check that the LEDs of all the devices turn green steady FC80GT Gateway 1 N L 2 C1 C2 N 1 FC80AC AUTO I O OFF ON COIL F20T60A FC80GCS COIL ...

Страница 10: ...k that the LEDs of all the devices immediately turn off the wired devices are now associated with each other Note if the LEDs of any devices stay red disconnect the power from the system reconnect it wait a minute and then repeat the procedure from item 1 FC80GT Gateway 2 N L 2 C1 C2 N 1 FC80AC AUTO I O OFF ON COIL F20T60A FC80GCS COIL ...

Страница 11: ...y been completed follow the instructions of the Add a product to this home menu in the App or Add a wired device OFF 1 Disconnect the voltage from the general switch 2 Install the new wired device 1 ON 3 Reconnect the power supply using the general switch and wait 1 minute for correct system startup 3 2 ...

Страница 12: ... same sequence of actions described here Check that the LEDs of all the devices are off with the exception of the device to add which must have a steady red LED 4 Complete the association of the new device as shown in Associate wired devices point 1 N L 2 C1 C2 N 1 FC80AC AUTO I O OFF ON COIL F20T60A FC80GCS COIL ...

Страница 13: ...T Smart DIN Gateway the result will be complete disconnection of the gateway from HomeKit disconnection from the Wi Fi Wi Fi network Caution this procedure has no effect on the association of the devices on the system that remain connected to each other 1 2 1 Press and hold down the reset pushbutton the LED turns green then switches off and at last turns orange 2 Release the pushbutton Reset to th...

Страница 14: ...cidental pressure of the reset pushbutton starts the association green LEDs are ON Press quickly the reset pushbutton of the FC80GT gateway to end it At the end the gateway LED switches off turns purple and then switches off again The reset is now complete At the end the gateway LED switches off turns purple and then switches off again The reset is now complete The LEDs of the associated devices t...

Страница 15: ...ontrol App and configure it so that all the other functions of the Smart electric system are available scenario customisation remote control with Smartphone voice control using your favourite voice assistant receive notifications in case of overload or fault in the system check electric consumptions for more info visit www homesystems legrandgroup com To download the Home Control App Use the App ...

Страница 16: ...o controls activate light relays using radio controls activate smart contactors using radio controls manage shutters Devices for civil series and junction box Gateway Modular gateway Gateway type F socket Gateway type E socket Sockets Wired module for modular socket Type F connected socket Type E connected socket Type F Plug play connected socket Type E Plug play connected socket Lights ZLD15 K441...

Страница 17: ...ush mounted wireless Night Day scenario control 1 2 3 4 Wall mounted wireless light control Wall mounted wireless double light control Wall mounted wireless 4 scenario control Wall mounted wireless In Out scenario control 1 2 Wireless module for mechanical switch Wall mounted wireless shutter control Wireless movement detector Wall mounted wireless Night Day scenario control ...

Страница 18: ...he association press the reset key of the Gateway until the LED turns green Check that the LEDs of all the devices immediately turn green steady with the exception of the wireless LEDs which will be off FC80GT Gateway 1 N L 2 C1 C2 N 1 FC80AC AUTO I O OFF ON COIL F20T60A FC80GCS COIL ...

Страница 19: ...se one of the control keys the LED flashes green release it and wait for the LED to turn off If the procedure fails remove and reinsert the battery then repeat the operation Wireless In Out scenario control 2 Warning if cover and plate are not fitted do not press the wireless control keys 3 KO ...

Страница 20: ...of all the devices immediately turn off the wired devices are now associated with each other 4 End the association press and release the reset key of the Gateway the LED switches off FC80GT Gateway 4 N L 2 C1 C2 N 1 FC80AC AUTO I O OFF ON COIL F20T60A FC80GCS COIL ...

Страница 21: ...Kitchen Bedroom Following the procedure below it is also possible to add other scenario controls or the Night Day wireless scenario control Note the wireless scenario control is preset for controlling Night and Day scenarios It is then possible to define the actions that will perform these scenarios using the Home Control App Note after completing the association wait a few minutes before activati...

Страница 22: ...f all the devices immediately turn green steady with the exception of the wireless LEDs which will be off FC80GT Gateway 1 Note it is not possible to associate the FC80CC Smart Contactor wired device to the wireless light control If the Home Control App has already been activated follow the instructions of the Add a product to this home menu in the App or N L 2 C1 C2 N 1 FC80AC AUTO I O OFF ON COI...

Страница 23: ... do not press the wireless control keys 3 Press and release one of the two control keys the LED flashes green wait until it turns off The control is now associated to your Smart electric system Let s now continue with the association of the light to the control If the procedure fails remove and reinsert the battery then repeat the operation 3 KO ...

Страница 24: ...LEDs flash three times blue Release the wireless control The control LED goes from blue flashing to off turns on again blue for a second and then turns off The LED of the wired device goes from blue flashing to green then turns back to blue for one second and then again to green If only one wired device needs to be associated go to item 8 to complete the association otherwise continue as indicated...

Страница 25: ...ntrol pushbutton until the LED flashes blue then release 7 Press and hold down one of the two keys of the wireless control to associate with the control touch three times gently and in quick sequence the wired device to associate 7 Connected module FC80RC Relè smart 2 2 6 ...

Страница 26: ... off turns on again blue for a second and then turns off The LED of the wired device goes from blue flashing to green then turns back to blue for one second and then again to green Wireless light control Connected module FC80RC Relè smart 2 8 End the association press and release the reset key of the Gateway the LED switches off FC80GT Gateway 8 ...

Страница 27: ...all the devices immediately turn off the wired devices are now associated with each other After associating the wireless light control to the smart relays it is possible to activate the connected loads N L 2 C1 C2 N 1 FC80AC AUTO I O OFF ON COIL F20T60A FC80GCS COIL ...

Страница 28: ...ile the LED is orange release the pushbuttons 2 Press and release the two control keys at the same time The LED will start flashing green then turns blue and then turns off 1 1 2 2 Wireless light control or Wireless shutter control Note the wireless control that is the subject of this procedure is an example for the complete list of wireless controls see the Compatibility with civil series section...

Страница 29: ...29 Btdin with Netatmo Installation Manual ...

Страница 30: ...o Spa reserves at any time the right to modify the contents of this booklet and to communicate in any form and modality the changes brought to the same BTicino SpA Viale Borri 231 21100 Varese www bticino com ...

Отзывы: