8. REMOTE SWITCH-OFF
The device has two inputs (AUX) for connecting a potential-free contact to which a telephone dialler can be
connected, for example, to remotely switch the thermostat on and off using a telephone.
The contact can be in one of the following positions:
- open: normal operation (according to the programming set via keypad).
- closed: thermostat in off operation.
The remote off condition is indicated on the display by the flashing of the symbol
to differentiate it from the
keypad off
condition.
Note:
This function must be operated via the Advanced Configuration (ADV) menu. The auxiliary input parameter
must be set to “diG”.
IMPORTANT:
Remote off condition (contact closed) takes priority over any other programming and therefore
the thermostat will remain in the off condition until the contact returns to the open position.
9. THERMOSTAT RESET
This can be used to delete any settings made and reload the default settings.
Proceed as follows:
Disconnect the thermostat from the wall base and reconnect it.
While the buttons are flashing, keep the button
pressed until “dEF” appears on the display.
Resetting to default settings will clears all settings in the configuration parameters:
Time and date
Edit programs
Change temperature (T1), T2, T3
Timer setting
Advanced menu configurations
IMPORTANT:
Resetting to default parameters will not delete the wireless configurations made on the thermostat.
To delete the wireless configurations, see chapter “
7.6.6. Def 25 : Thermostat wireless configuration reset
”.
10. INSTALLATION
10.1. SAFETY WARNINGS
The following instructions must be observed when installing the product:
The product must be installed by a qualified professional, scrupulously respecting the wiring diagram.
Do not power or connect the product if any of its parts are damaged. Do not carry out repairs and contact
technical support directly.
Do not use the product for purposes other than those specified.
The device must be installed and put into operation in accordance with current legislation on electrical
systems.
The product can be used in a category 3 and grade 2 pollution measurement environment.
Where it is necessary to guarantee galvanic insulation towards the boiler, it is essential to install the REL1C
accessory (see diagram SD541-6054 in the MTR2000 product card).
10.2. HOW TO START THE THERMOSTAT
The Thermarp accessory is ideal for wall mounting. Alternatively, it can be installed on a flush mounting box
Mod. 503.
The thermostat must be installed at a height of about 1.5 m above the floor, protected from direct radiation,
away from doors, windows, heat sources, positions with excess or total lack of ventilation.
The YOKIS THERMARP thermostat runs on batteries (2 x 1.5 V AAA / LR03 type batteries).
Fix the base to the wall using the screws provided.
Open the rear compartment of the thermostat timer to
insert the batteries
, checking the polarity indicated
on the battery compartment.
1.
2.
•
•
•
•
•
1.
2.
3.
4.
5.
6.
1.