MUST READ-2

Some DIY installations have been successful, but these are exceptions. Most have resulted in equipment failure, 
due to lack of knowledge and experience. A few of the problems result from DIY's lack of knowledge in the 
following areas:
* Sizing and selecting correct type, size and model of cooling and/or heating equipment.
* Sizing and installing correct electric circuit breakers and wires.
* Wiring the units correctly and properly.
* Taping the ends, connecting to indoor and outdoor units correctly and properly.
* Vacuuming the inter-connecting refrigerant lines.
* Checking and/or fixing the refrigerant leaks.
* Checking and/or fixing the condensate drain leaks.
* Releasing the refrigerant from outdoor unit to indoor unit.
* Running the unit to check all the unit functions.
* Conducting the installation or trouble-shooting with correct tools, experience or professional knowledge to 
  correct the problem.

RECEIVING AND FREIGHT DAMAGE

* Freight (package/unit) shall be checked thoroughly for damage at receiving before accepting by signing on the 
  carrier's delivery paperwork.
* Upon shipment being signed for acceptance, it becomes a binding document as to the condition of the products 
  on delivery. We cannot process any shipping damage claim, if you accept the delivery.
* If damage is found at delivery, both you and the delivery driver must make notes on the delivery receipt or other 
  freight paperwork detailing the damage found by marking position/parts on unit, description of damage, time/
  date, your name, contact phone, etc. on the delivery documents. Make a copy of the marked delivery receipt.

CUSTOMER AND TECHNICIAN MUST READ

* If the damage is minor or partial, that you choose to accept, you can contact the distributor or YMGI to discuss 
  the possible replacement of the damaged part.
* If refusal of the shipment

 

is needed due to severe freight damage, 

DO NOT

 sign the carrier's delivery receipt 

  document indicating that you accept the products.  Mark receipt "REFUSED DUE TO FREIGHT DAMAGE." 
  Sign and date along with the delivery driver's signature and date.
* Take pictures showing the damage, before the delivery driver leaves.
* If you accept the delivery or fail to note damage on the driver's delivery receipt, the ability to claim freight 
  damage is lost and YMGI will not replace the unit on this basis.
* Contact the distributor or YMGI, report the damage by forwarding the marked delivery receipt copy and pictures.
* Only after YMGI verifies with the carrier the necessary detailed notes of received freight damage, will the 
  damaged products be eligible for replacement.
* If the returned products are found not damaged, YMGI will treat it as a return and will charge you 25% of 
  product value plus added shipping cost.

RETURN-YMGI GROUP POLICIES & RETURN GOODS AUTHORIZATION (RGA) 

All sales are final. If the customer wishes to return a product, the following 

Return Policies

 apply.

A. Only those products (units, parts or accessories) under the following conditions, are eligible for return:
1) Products are returned within 30 days of their original shipment date from YMGI

2) Products have not been installed.
3) No damage exists on the products being returned.
4) No missing products. 
5) Products and packages are clean.
6) No duct tape or marking on the product or box.
7) Products are still their original package, in good shape and in re-sellable condition, as YMGI determines.

B. Preapproval steps for your return request:

1) Contact your distributor or YMGI to request a return.
2) Photograph your product and box to show details
3) YMGI will review your request, along with the pictures and any other details pertaining to your request.
4) If YMGI agrees to process your return request, a form called

 Return Goods Authorization (RGA), along with 

    an assigned RGA # 

 will be forwarded to your distributor or you.

5) Any return without YMGI Group approved RGA #, will not be accepted. 

P31 OF 36

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

MUST READ-2

F. Charges for your return:

1)A restocking charge of 25% creditable invoice value.
2)All return shipping fees.
3)Additional fees will be charged, if products are found to be damaged, missing or used.
4)YMGI will notify the distributor of the charges only after the inspection and assessment of the returned products 
    has been completed.

Attention:

1) Returned products must be shipped within 7 days of YMGI's releasing of 

RGA #

.

2) 

All RGA

 shipping shall be prepaid by the customer. 

YMGI will not accept any COD freight

.

YMGI GROUP DISCLAIMING-1: 

YMGI Group will NOT accept any return, or may not honor 100% credit for any return of Product(s)/Part(s)/
Accessories, in any of the following cases:
* Return requests made 30 or more days after the date of original sales shipping from YMGI Group warehouse.
* Return shipment is initiated 8 days or more after the RGA is approved.
* Returned products received not displaying an YMGI-approved valid 

RGA #

.

* Returned products received C.O.D.
* Returned products not received in the original packaging.
* Returned products received with non-repairable packaging, including duct tape or marks on units or carton 
  boxes.
* Returned products received with missing units/parts/accessories.
* Returned products received, are found to be non-functional or damaged.

YMGI GROUP DISCLAIMING-2: 

YMGI Group will not be responsible for any losses of returned unit(s)/part(s)/accessories in transition to YMGI 

  Group warehouse. 
* YMGI Group RGA is valid for seven (7) days from the original issuing date. Returns will not be accepted, if 
  shipping is made 8 or more days after the YMGI Group RGA is issued.

C. YMGI must verify the following before you can pack your products:

1) No products (units, parts, accessories) are missing.
2) No damage is found.
3) The products are in the original packaging.
4) No duct tape on any product or box.
5) Pictures have been taken and sent to YMGI to verify the product and boxes are not damaged.
6) The RGA has been completed and a copy has been returned to YMGI, via email or fax.
7) YMGI has approved the request in writing.

D. Shipping Preparation:

1) Package all products in a manner in which no damage can occur to the product and secure to a pallet.
2) Take and forward pictures of packed pallets for YMGI to verify proper packaging and no existing damage.
3) Include the YMGI approved RGA# in the shipping documents.
4) YMGI reserves the right to approve or deny any shipments.
5) YMGI can arrange shipping for you, but not at YMGI's cost. If this option is chosen, a packing list and BOL will 
    be issued to you through YMGI.
6) If the above option is not chosen, you will be responsible for all freight charges. YMGI will not accept any 
    returned items COD.
7) Place the package in an area which is accessible to the shipping company for pickup and limits the possibility 
    of damage to the product.  Customer must be present at the time of freight pick up.

After shipping, fax

 

the BOL to YMGI Group at 1-866-377-3355 or email to [email protected]

detailing the information of the freight company and their tracking number.

E.Freight Damage:

1) YMGI Group will inspect returned items  
2) Claiming of freight damage from a customer hired carrier will be the customer's responsibility. 
3) Claiming of freight damage from a YMGI hired carrier will be YMGI's responsibility.

CUSTOMER AND TECHNICIAN MUST READ

P32 OF 36

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

Содержание WMMS-09K-V2A(57)2

Страница 1: ...nd Heat Pump 09 24k 16 SEER This product is designed and manufactured free from defects in material and workmanship for normal use and maintenance Installation operation maintenance and service shall...

Страница 2: ...trouble free installation proper operation of your products for many years to come YMGI Group POB 1559 O Fallon MO 63366 is the only party who holds the final explanation in authorized writing about...

Страница 3: ...e humidity ranges installation operation maintenance service warranty parts and so on 4 Properly select correct most suitable YMGI product models of units and accessories for your HVAC applications jo...

Страница 4: ...he installation 5 Supply electrical power V Ph Hz measured at wiring terminal block of Indoor unit outdoor unit 7 Wire gauge length and terminal colors between circuit breaker disconnect switch to out...

Страница 5: ...Pump 2 Load calculation must be done carefully and correctly by experienced technician for each room that needs to be conditioned before sizing unit and selecting correct model Not to undersize or ov...

Страница 6: ...nstall them in secured positions PVC line set cover is recommended to protect against rain and sunlight and other potential damage DO NOT blow the cold air directly towards people for prolonged period...

Страница 7: ...3 10 3 10 3 10 26 Evaporator Row fin Gap Inch 2 3 50 2 3 50 2 7 127 2 7 127 27 Evaporator Coil W H x D Inch 24 11 3 5 1 24 11 3 5 1 25 13 15 12 1 512 17x27X1 28 Swing Motor Model MP24BA MP24BA MP28VB...

Страница 8: ...d is discharged so that the indoor room temperature is decreased The cooling capacity will increase or decrease depending on the outdoor air temperature Anti freezing function If the unit is running i...

Страница 9: ...notice then the clock symbol is not flashing Note Under the Dry mode the fan speed isn t adjustable low fan speed is imperative High fan High fan High fan AUTO NAMES AND FUNCTIONS OF WIRELESS REMOTE C...

Страница 10: ...set up by experiments or experience the target temperature quite few degrees higher than what you really want in order to reach a satisfied or more precise indoor comfort This is a common drawback of...

Страница 11: ...ut After 30s later replace them back into the remote control in the correct polarities If the remote control still doesn t work properly then the remote control may need to be replaced Sketch map for...

Страница 12: ...remote control 1 Is the remote control out of battery 2 Is remote control in direct sunlight 3 Is remote control signal blocked 4 Is remote control too far away from indoor unit 5 Is the fuse on indo...

Страница 13: ...protection Heating LED Off 3S Blinks 6 times HE Compressor de managet protection rotor locked doesn t rotate Heating LED Off 3S Blinks 14 times L0 Airflow switch error TBD L1 Humidity sensor error TB...

Страница 14: ...uring gas sensor error Running LED Off 3S Blinks 21 times HP Solar AC solar power input voltage is higher than 180V TBD dA AHU or RT discharge air relative humidity sensor error TBD dE AHU or RT fresh...

Страница 15: ...r Cooling LED Off 3S Blinks 7 times FC Slide door error or air louver mechanism error TBD FE Over load sensor error TBD H8 Water level high overflow protection Heating LED Off 3S Blinks 8 times H9 Ele...

Страница 16: ...0 conducted by a qualified HVAC technician s as detailed in the checklist of the Limited Product Warranty Policy and Limited Product Warranty Registration Card Form along with a properly detailed inst...

Страница 17: ...her details pertaining to your request 4 If YMGI agrees to process your return request a form called Return Goods Authorization RGA along with an assigned RGA will be forwarded to your distributor or...

Страница 18: ...derations All unit removal re installation and shipping cost are the responsibility of the customer YMGI maintains the final authority as to unit replacement Replacement will be made with the same mod...

Страница 19: ...AND INSTALLATION SERVICE MAINTENANCE NOTES Notes Asked for Your Technician for Help Did You Ask YMGI Tech for Help INSTALLATION NOTES Original Installation Company Name Technician Name Phone HVAC Lice...

Отзывы: