P27 OF 36

P28 OF 36

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

e2

Warning: water flow low

TBD

e3

Oil level low protection

TBD

e7

System pressure difference protection

TBD

eA

Heat exchanger-pressure transducer sensor error (similar to lower pressure

transducer protection)

TBD

eC

Oil-pressure transducer sensor error (similar to lower pressure transducer

protection)

TBD

e0

Economizer-discharge temp. sensor error

TBD

e9

Economizer-discharge pressure sensor error

TBD

eF

Compressor brand sensor error

TBD

bH

Water pump temp. sensor

TBD

oE

Any other error that the outdoor unit needs to stop

TBD

E8

Anti-high temperature protection

Running LED-Off 3S, Blinks 8 times

E9

Anti-cold blowing (discharging) protection

Running LED-Off 3S, Blinks 9 times

F1

Indoor air temp. sensor error/bad-broken, shorted…

Cooling LED-Off 3S, Blinks 1 time

F2

Indoor coil temp. sensor error/bad-broken, shorted…

Cooling LED-Off 3S, Blinks 2 times

F4

Outdoor coil temp. sensor error/bad-broken, shorted…

Cooling LED-Off 3S, Blinks 4 times

F5

Compressor discharge temp. sensor error/bad-broken, shorted…

Cooling LED-Off 3S, Blinks 5 times

F7

Cooling-oil return error

Cooling LED-Off 3S, Blinks 7 times

FC

Slide door error, or air louver mechanism error

TBD

FE

Over-load sensor error

TBD

H8

Water level-high /overflow protection

Heating LED-Off 3S, Blinks 8 times

H9

Ele. heater error

Heating LED-Off 3S, Blinks 9 times

b7

Outlet temp. sensor error

Cooling LED-Off 3S, Blinks 22 times

b5

Inlet temp. sensor error

Cooling LED-Off 3S, Blinks 19 times

d1

DRM running mode 1

d2

DRM running mode 2

d3

DRM running mode 3

ERROR AND PROTECTION CODE SUMMARY

SAMPLE SYSTEM LAYOUT

Notes: Actual unit/ part appearance and 
installation may vary from the illustrated.
Subject to continuous improvement and 
change without notice.

Wrench

Air out

Drainage hose

Connection pipe

Disconnect Box

To correctly sized 

HVAC CIRCUIT 

BREAKER

Display icon (May vary open models):

Air wall sleeve

Guide panel

Filter

Bolt

Nut

Pipe/wire
wall sleeve

Digital
display

Lineset PVC cover

Notes

:

1.Some codes are not malfunctions and will not require you to do anything, since the unit will resume normal 
   functions once the unit finishes its designated work such as defrost, oil return...
2.Some other codes denote malfunctions and the unit will not resume normal functions until your technician 
   checks your unit and fixes the problems such as dirty coils, clogged filters, bad control boards...You can 
   have your technician to call 866-833-3138 for help of  technical support and trouble-shoot.

UNIT MAINTENANCE & 

SER

VICE GUIDE

UNIT MAINTENANCE & 

SER

VICE GUIDE

Содержание WMMS-09K-V2A(57)2

Страница 1: ...nd Heat Pump 09 24k 16 SEER This product is designed and manufactured free from defects in material and workmanship for normal use and maintenance Installation operation maintenance and service shall...

Страница 2: ...trouble free installation proper operation of your products for many years to come YMGI Group POB 1559 O Fallon MO 63366 is the only party who holds the final explanation in authorized writing about...

Страница 3: ...e humidity ranges installation operation maintenance service warranty parts and so on 4 Properly select correct most suitable YMGI product models of units and accessories for your HVAC applications jo...

Страница 4: ...he installation 5 Supply electrical power V Ph Hz measured at wiring terminal block of Indoor unit outdoor unit 7 Wire gauge length and terminal colors between circuit breaker disconnect switch to out...

Страница 5: ...Pump 2 Load calculation must be done carefully and correctly by experienced technician for each room that needs to be conditioned before sizing unit and selecting correct model Not to undersize or ov...

Страница 6: ...nstall them in secured positions PVC line set cover is recommended to protect against rain and sunlight and other potential damage DO NOT blow the cold air directly towards people for prolonged period...

Страница 7: ...3 10 3 10 3 10 26 Evaporator Row fin Gap Inch 2 3 50 2 3 50 2 7 127 2 7 127 27 Evaporator Coil W H x D Inch 24 11 3 5 1 24 11 3 5 1 25 13 15 12 1 512 17x27X1 28 Swing Motor Model MP24BA MP24BA MP28VB...

Страница 8: ...d is discharged so that the indoor room temperature is decreased The cooling capacity will increase or decrease depending on the outdoor air temperature Anti freezing function If the unit is running i...

Страница 9: ...notice then the clock symbol is not flashing Note Under the Dry mode the fan speed isn t adjustable low fan speed is imperative High fan High fan High fan AUTO NAMES AND FUNCTIONS OF WIRELESS REMOTE C...

Страница 10: ...set up by experiments or experience the target temperature quite few degrees higher than what you really want in order to reach a satisfied or more precise indoor comfort This is a common drawback of...

Страница 11: ...ut After 30s later replace them back into the remote control in the correct polarities If the remote control still doesn t work properly then the remote control may need to be replaced Sketch map for...

Страница 12: ...remote control 1 Is the remote control out of battery 2 Is remote control in direct sunlight 3 Is remote control signal blocked 4 Is remote control too far away from indoor unit 5 Is the fuse on indo...

Страница 13: ...protection Heating LED Off 3S Blinks 6 times HE Compressor de managet protection rotor locked doesn t rotate Heating LED Off 3S Blinks 14 times L0 Airflow switch error TBD L1 Humidity sensor error TB...

Страница 14: ...uring gas sensor error Running LED Off 3S Blinks 21 times HP Solar AC solar power input voltage is higher than 180V TBD dA AHU or RT discharge air relative humidity sensor error TBD dE AHU or RT fresh...

Страница 15: ...r Cooling LED Off 3S Blinks 7 times FC Slide door error or air louver mechanism error TBD FE Over load sensor error TBD H8 Water level high overflow protection Heating LED Off 3S Blinks 8 times H9 Ele...

Страница 16: ...0 conducted by a qualified HVAC technician s as detailed in the checklist of the Limited Product Warranty Policy and Limited Product Warranty Registration Card Form along with a properly detailed inst...

Страница 17: ...her details pertaining to your request 4 If YMGI agrees to process your return request a form called Return Goods Authorization RGA along with an assigned RGA will be forwarded to your distributor or...

Страница 18: ...derations All unit removal re installation and shipping cost are the responsibility of the customer YMGI maintains the final authority as to unit replacement Replacement will be made with the same mod...

Страница 19: ...AND INSTALLATION SERVICE MAINTENANCE NOTES Notes Asked for Your Technician for Help Did You Ask YMGI Tech for Help INSTALLATION NOTES Original Installation Company Name Technician Name Phone HVAC Lice...

Отзывы: