background image

UNIT OPERA

TION

UNIT OPERA

TION

P17 OF 36

P18 OF 36

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

Once the U-TOUCH stars appear, the remote will send a signal of the remote-local temperature to the indoor unit, 
and this remote-local temperature will supersede the return air temperature as the unit's target temperature. 
Every 10 minutes such signal will be sent from the remote to the indoor unit updating the remote-local 
temperature. If at any time during this process no signal is received by the indoor unit from the remote, the unit 
will switch back to the previously set temperature before the U-TOUCH feature is activated. To turn the U-
TOUCH feature off, simply press the U-TOUCH button until you see the symbol disappear from the remote 
screen. By doing so, the return air temperature will take place of remote-local temperature as the unit's target 
temperature. U-TOUCH is what YOU WANT. U-TOUCH feature brings to you a true comfort level wherever and 
whenever you want.

REMOTE CONTROL-BUTTON NAME & FUNCTIONS

"SWING" BUTTON:

 Hold the swing button (symbol 

shown above) for more than 2 seconds and the 
indoor air louver will start to swing between the 
highest and lowest limits. Once the swing button is 
released the louver will stay in the last position where 
the button was released.  
If the swing button is pushed just once the swing icon 
will appear on the remote and the louver will swing 
up and down continuously between the highest and 
lowest points. Push the swing button once more and 
the icon will disappear on the remote and the louver 
will remain at the last point the button was pushed. 
When the unit is powered off by the remote the louver 
will close on the indoor unit.
Press this button to set up the desired swing angle 
which circularly changes as below. (Insert swing 
picture)

"U-TOUCH" BUTTON:

 Since the indoor unit is normally mounted high up on the wall or attached to the ceiling, the 

temperature at where the return air sensor is installed inside the indoor unit is higher than what it is where the 
area people stand and can feel (4 to 7 feet above the floor). If the unit uses the return air temperature as its 
target control, people may feel colder than what they really want (target) in both cooling mode and heating mode. 
The facts of air stratification and warm air rising and cold air dropping require users to set up, by experiments or 
experience, the target temperature quite few degrees higher than what you really want , in order to reach a 
satisfied or more precise indoor comfort. This is a common drawback of AC/HP units made by other manufacturers.
With YMGI's U-touch feature, this can be avoided and your comfort level can be improved.
When you press the U-TOUCH button on the remote control, the unit will use the temperature where the remote 
is located as its target temperature control. Once you do so, you will notice a figure of a person surrounded by 
stars appear on the remote. 

"SWING UP AND DOWN" BUTTON

Press this button, to set up swing angle, 
circularly changes as below:

which 

This is an universal use remote control. If remote 
control sends the following three kinds of status 
that the swing status of main unit will be:

When the guide louver start to swing up and down, if 
turn off the Swing, the air guide louver will stop at 
current position.

which indicates the guide louver swings up and 

down between that all five positions.

H1

T

H2

Warmer

Colder

Warm air rises

Cold air drops

T+

Temp sensor

Wall mount indoor unit

"U-Touch" Feature Is Activated: 

"U-Touch" Feature Is NOT Activated: 

Roof

Floor

Signal (communication)

Remete control
(Temp sensor)

T

H1

T

Roof

Floor

(Feel More 
Comfortable)

(May Feel Colder than 
You Want in Summer 
and Winter)

REMOTE CONTROL-BUTTON NAME & FUNCTIONS

SYMBOL DISPLAY

When power is first applied to the unit but the power has not been turned on by the remote control, then the red 
power light only is displayed. When the unit has been powered on by the remote control then the running LED is 
lit and the current running mode symbol is displayed at the same time.

COOLING:

  Running symbol and cooling symbol are lit.

HEATING:

   Running lamp and heating symbol are lit.

DRY:

  Running lamp and dry lamp are lit

FAN:

  Running lamp and fan lamp are lit.

AUTO:

   Auto lamp, running lamp and actual running mode are lit.

ALPHA NUMERIC DISPLAY

O

O

The setting temperature range for the unit is 61  to 86 F.  

O

O

* Under AUTO mode unit will display 77 F for cooling and 68 F for heating modes.

GUIDE FOR OPERATION- GENERAL 
OPERATION

1) After powered on, press ON/OFF button, the unit 
    will start to run.(Note: When it is powered off, the 
    guide louver of main unit will close automatically.)
2) Press MODE button, select desired running mode, 
    or press COOL or HEAT mode to enter into the 
    corresponding operation directly.
3) Pror - button, to set the desired 
    temperature. (It is unnecessary to set the temp. at 
    AUTO mode.)
4) Pressing FAN button, set fan speed, can select 
    AUTO FAN, LOW, MED, and HIGH.
5)  Pressing     button, to select the swing.

OPERATION OF REMOTE CONTROL


Содержание WMMS-09K-V2A(57)2

Страница 1: ...nd Heat Pump 09 24k 16 SEER This product is designed and manufactured free from defects in material and workmanship for normal use and maintenance Installation operation maintenance and service shall...

Страница 2: ...trouble free installation proper operation of your products for many years to come YMGI Group POB 1559 O Fallon MO 63366 is the only party who holds the final explanation in authorized writing about...

Страница 3: ...e humidity ranges installation operation maintenance service warranty parts and so on 4 Properly select correct most suitable YMGI product models of units and accessories for your HVAC applications jo...

Страница 4: ...he installation 5 Supply electrical power V Ph Hz measured at wiring terminal block of Indoor unit outdoor unit 7 Wire gauge length and terminal colors between circuit breaker disconnect switch to out...

Страница 5: ...Pump 2 Load calculation must be done carefully and correctly by experienced technician for each room that needs to be conditioned before sizing unit and selecting correct model Not to undersize or ov...

Страница 6: ...nstall them in secured positions PVC line set cover is recommended to protect against rain and sunlight and other potential damage DO NOT blow the cold air directly towards people for prolonged period...

Страница 7: ...3 10 3 10 3 10 26 Evaporator Row fin Gap Inch 2 3 50 2 3 50 2 7 127 2 7 127 27 Evaporator Coil W H x D Inch 24 11 3 5 1 24 11 3 5 1 25 13 15 12 1 512 17x27X1 28 Swing Motor Model MP24BA MP24BA MP28VB...

Страница 8: ...d is discharged so that the indoor room temperature is decreased The cooling capacity will increase or decrease depending on the outdoor air temperature Anti freezing function If the unit is running i...

Страница 9: ...notice then the clock symbol is not flashing Note Under the Dry mode the fan speed isn t adjustable low fan speed is imperative High fan High fan High fan AUTO NAMES AND FUNCTIONS OF WIRELESS REMOTE C...

Страница 10: ...set up by experiments or experience the target temperature quite few degrees higher than what you really want in order to reach a satisfied or more precise indoor comfort This is a common drawback of...

Страница 11: ...ut After 30s later replace them back into the remote control in the correct polarities If the remote control still doesn t work properly then the remote control may need to be replaced Sketch map for...

Страница 12: ...remote control 1 Is the remote control out of battery 2 Is remote control in direct sunlight 3 Is remote control signal blocked 4 Is remote control too far away from indoor unit 5 Is the fuse on indo...

Страница 13: ...protection Heating LED Off 3S Blinks 6 times HE Compressor de managet protection rotor locked doesn t rotate Heating LED Off 3S Blinks 14 times L0 Airflow switch error TBD L1 Humidity sensor error TB...

Страница 14: ...uring gas sensor error Running LED Off 3S Blinks 21 times HP Solar AC solar power input voltage is higher than 180V TBD dA AHU or RT discharge air relative humidity sensor error TBD dE AHU or RT fresh...

Страница 15: ...r Cooling LED Off 3S Blinks 7 times FC Slide door error or air louver mechanism error TBD FE Over load sensor error TBD H8 Water level high overflow protection Heating LED Off 3S Blinks 8 times H9 Ele...

Страница 16: ...0 conducted by a qualified HVAC technician s as detailed in the checklist of the Limited Product Warranty Policy and Limited Product Warranty Registration Card Form along with a properly detailed inst...

Страница 17: ...her details pertaining to your request 4 If YMGI agrees to process your return request a form called Return Goods Authorization RGA along with an assigned RGA will be forwarded to your distributor or...

Страница 18: ...derations All unit removal re installation and shipping cost are the responsibility of the customer YMGI maintains the final authority as to unit replacement Replacement will be made with the same mod...

Страница 19: ...AND INSTALLATION SERVICE MAINTENANCE NOTES Notes Asked for Your Technician for Help Did You Ask YMGI Tech for Help INSTALLATION NOTES Original Installation Company Name Technician Name Phone HVAC Lice...

Отзывы: