Pd

Current checking-connection error (U-V-W not connected accordingly)

TBD

PE

Temperature sensor drifting protection

TBD

PF

Driving board-ambient temperature sensor error

TBD

PH

DC incoming voltage too high (program checking)

Cooling LED-Off 3S, Blinks 11 times

PL

DC incoming voltage too low (program checking)

Cooling LED-Off 3S, Blinks 21 times

PP

AC incoming power abnormal (too low or too high)

TBD

PU

Capacitor-charging circuit error

Heating LED-Off 3S, Blinks 17 times

U7

4-way switch valve abnormal

Heating LED-Off 3S, Blinks 20 times

U6

Oil temperature too high

Heating LED-Off 3S, Blinks 16 times

U4

Compressor rotation reversed

Heating LED-Off 3S, Blinks 14 times

U5

Rectifying current checking error

Heating LED-Off 3S, Blinks 13 times

U3

DC main bus voltage drop

Heating LED-Off 3S, Blinks 20 times

U1

Compressor phase current checking circuit error

Heating LED-Off 3S, Blinks 13 times

U2

Compressor phase loss protection

Heating LED-Off 3S, Blinks 12 times

UC

Filter needs to be cleaned

TBD

U8

PG motor (indoor) checking circuit error

Running LED-Off 3S, Blinks 17 times

U9

Outdoor fan motor checking circuit error

Running LED-Off 3S, Blinks 18 times

UF

De-actuate remote or control, from a long distance

TBD

C7

PTC heater sensor error

Heating LED-Off 3S, Blinks 9 times

FJ

Discharge/vent air temperature sensor error

TBD

L8

Storage tank water level switch error

TBD

d3

AC condensate: anti-freezing sensor error

TBD

d4

Domestic water: anti-freezing sensor error

TBD

d5

Return water sensor error

TBD

d6

Defrost coil sensor error

TBD

d7

Back-up hot water temperature sensor error

TBD

d8

Hot water outlet temperature sensor error

TBD

d9

Hot water inlet temperature sensor error

TBD

db

Temp. Sensor Error-after metering device (cap. Tube, or EXV)

TBD

dc

Temp. Sensor Error-suction tube

TBD

dP

Temp. Sensor Error-discharge tube

TBD

dL

Low voltage reluctance/reluctor error

TBD

L9

Compressor Protection-calculated input is too high

Running LED-Off 3S, Blinks 20 times

dF

Temp. Sensor Error-solar water heater-water outlet

TBD

dH

Temp. Sensor Error-solar water heater-assistant ele. heater

TBD

dU

Door-lock sensor: card is not in

TBD

dJ

AC phase protection (lost or reversed)

TBD

d0

Fan motor speed communication error

TBD

Eo

Specia function board error

TBD

dn

M ulitiple zone-pipe connection doesn't match with comm. wire connection TBD

Cn

Not for AC: Buring gas density too high

Cooling LED-Off 3S, Blinks 23 times

Fn

Not for AC: Buring gas sensor error

Running LED-Off 3S, Blinks 21 times

HP

Solar AC: solar power input voltage is higher than 180V

TBD

dA

AHU or RT: discharge air-relative humidity sensor error

TBD

dE

AHU or RT: fresh air-relative humidity sensor error

TBD

Fr

AHU or RT: fresh air-temp. sensor error

TBD

UA

DC inverter driving error 1

TBD

dr

AHU or RT: air flow pressure sensor error

TBD

Ub

DC inverter driving error 2

TBD

Ud

DC inverter driving error 3

TBD

UE

DC inverter driving error 4

TBD

LU

Compressor power input limit / decrease HZ (system power input)

Cooling LED-Off 3S, Blinks 24 times

LA

Outdoor unit fan motor protection (not rotating, or not connected). If 2

motors, motor 1-L3, motor 2-LA

Running LED-Off 3S, Blinks 24 times

A5

Condensing coil-inlet temp. sensor error (=F5 in commercial units)

TBD

A7

Condensing coil-outlet temp. sensor error (=F7 in commercial units)

TBD

e4

Compressor dischage temp. (=pressure) too high

TBD

e8

Over-load protection (outdoor coil temp. too high)

TBD

e1

Dicharge pressure sensor error

TBD

ee

DC inverter driving chip error

TBD

JF

Indoor unit-testing board comm. Error (after 3-minutes)

TBD

rF

RF module error (once powered, the MCU tries to send commands, via SPI,

to RF, if RF doesn't receives it, error shows)

TBD

Uu

Solar AC: battery bank discharged too much and the output voltage is lower

than 295V

TBD

no

For VRF groups: DC unit's display board can not receive any data from the

fixed speed comp. unit, will show "no" after 8 seconds

TBD

E6+IDU

Temp.

Communication error (ID display-OD main board) and outdoor temperature

sensor error

TBD

E7+ODU

Temp.

Communication error (ID unit-OD unit) and outdoor temperature sensor

error

TBD

Fu

AHU or RT: dust sensor error

TBD

ERROR AND PROTECTION CODE SUMMARY

ERROR AND PROTECTION CODE SUMMARY

Notes

:

1.Some codes are not malfunctions and will not require you to do anything, since the unit will resume normal 
   functions once the unit finishes its designated work such as defrost, oil return...
2.Some other codes denote malfunctions and the unit will not resume normal functions until your technician 
   checks your unit and fixes the problems such as dirty coils, clogged filters, bad control boards...You can 
   have your technician to call 866-833-3138 for help of  technical support and trouble-shoot.

Notes

:

1.Some codes are not malfunctions and will not require you to do anything, since the unit will resume normal 
   functions once the unit finishes its designated work such as defrost, oil return...
2.Some other codes denote malfunctions and the unit will not resume normal functions until your technician 
   checks your unit and fixes the problems such as dirty coils, clogged filters, bad control boards...You can 
   have your technician to call 866-833-3138 for help of  technical support and trouble-shoot.

UNIT MAINTENANCE & 

SER

VICE GUIDE

UNIT MAINTENANCE & 

SER

VICE GUIDE

Содержание WMMS-09K-V2A(57)2

Страница 1: ...nd Heat Pump 09 24k 16 SEER This product is designed and manufactured free from defects in material and workmanship for normal use and maintenance Installation operation maintenance and service shall...

Страница 2: ...trouble free installation proper operation of your products for many years to come YMGI Group POB 1559 O Fallon MO 63366 is the only party who holds the final explanation in authorized writing about...

Страница 3: ...e humidity ranges installation operation maintenance service warranty parts and so on 4 Properly select correct most suitable YMGI product models of units and accessories for your HVAC applications jo...

Страница 4: ...he installation 5 Supply electrical power V Ph Hz measured at wiring terminal block of Indoor unit outdoor unit 7 Wire gauge length and terminal colors between circuit breaker disconnect switch to out...

Страница 5: ...Pump 2 Load calculation must be done carefully and correctly by experienced technician for each room that needs to be conditioned before sizing unit and selecting correct model Not to undersize or ov...

Страница 6: ...nstall them in secured positions PVC line set cover is recommended to protect against rain and sunlight and other potential damage DO NOT blow the cold air directly towards people for prolonged period...

Страница 7: ...3 10 3 10 3 10 26 Evaporator Row fin Gap Inch 2 3 50 2 3 50 2 7 127 2 7 127 27 Evaporator Coil W H x D Inch 24 11 3 5 1 24 11 3 5 1 25 13 15 12 1 512 17x27X1 28 Swing Motor Model MP24BA MP24BA MP28VB...

Страница 8: ...d is discharged so that the indoor room temperature is decreased The cooling capacity will increase or decrease depending on the outdoor air temperature Anti freezing function If the unit is running i...

Страница 9: ...notice then the clock symbol is not flashing Note Under the Dry mode the fan speed isn t adjustable low fan speed is imperative High fan High fan High fan AUTO NAMES AND FUNCTIONS OF WIRELESS REMOTE C...

Страница 10: ...set up by experiments or experience the target temperature quite few degrees higher than what you really want in order to reach a satisfied or more precise indoor comfort This is a common drawback of...

Страница 11: ...ut After 30s later replace them back into the remote control in the correct polarities If the remote control still doesn t work properly then the remote control may need to be replaced Sketch map for...

Страница 12: ...remote control 1 Is the remote control out of battery 2 Is remote control in direct sunlight 3 Is remote control signal blocked 4 Is remote control too far away from indoor unit 5 Is the fuse on indo...

Страница 13: ...protection Heating LED Off 3S Blinks 6 times HE Compressor de managet protection rotor locked doesn t rotate Heating LED Off 3S Blinks 14 times L0 Airflow switch error TBD L1 Humidity sensor error TB...

Страница 14: ...uring gas sensor error Running LED Off 3S Blinks 21 times HP Solar AC solar power input voltage is higher than 180V TBD dA AHU or RT discharge air relative humidity sensor error TBD dE AHU or RT fresh...

Страница 15: ...r Cooling LED Off 3S Blinks 7 times FC Slide door error or air louver mechanism error TBD FE Over load sensor error TBD H8 Water level high overflow protection Heating LED Off 3S Blinks 8 times H9 Ele...

Страница 16: ...0 conducted by a qualified HVAC technician s as detailed in the checklist of the Limited Product Warranty Policy and Limited Product Warranty Registration Card Form along with a properly detailed inst...

Страница 17: ...her details pertaining to your request 4 If YMGI agrees to process your return request a form called Return Goods Authorization RGA along with an assigned RGA will be forwarded to your distributor or...

Страница 18: ...derations All unit removal re installation and shipping cost are the responsibility of the customer YMGI maintains the final authority as to unit replacement Replacement will be made with the same mod...

Страница 19: ...AND INSTALLATION SERVICE MAINTENANCE NOTES Notes Asked for Your Technician for Help Did You Ask YMGI Tech for Help INSTALLATION NOTES Original Installation Company Name Technician Name Phone HVAC Lice...

Отзывы: