Error
Code

Description

Indoor Unit LED Display

C1

Current arch protection

Running LED-Off 3S, Blinks 12 times

C2

Current leakage protection

Running LED-Off 3S, Blinks 13 times

C3

Mis-wiring protection

Running LED-Off 3S, Blinks 14 times

C5

Jumper error protection

Running LED-Off 3S, Blinks 15 times

C6

No-ground

Running LED-Off 3S, Blinks 16 times

Cd

Too much CO2 protection

TBD

CF

Current short-cut protection

TBD (Buzzer will sound once every 2 sec.)

d1

WSHP: UV light error

TBD

E0

Commercial: Water pump overload/error/flow switch error

Running LED-Off 3S, Blinks 10 times

E1

System high pressure protection

Running LED-Off 3S, Blinks 1 time

E2

Anti-freezing protection (heat exchanger-ID, OD)

Running LED-Off 3S, Blinks 2 times

E3

Low pressure protection (run cooling when OD is too cold)

Running LED-Off 3S, Blinks 3 times

E4

Compressor dischage pressure too high

Running LED-Off 3S, Blinks 4 times

E5

System/compressor current too high

Running LED-Off 3S, Blinks 5 times

E6

Communication error (ID-OD)

Running LED-Off 3S, Blinks 6 times

E7

Mode clash (some ID runs cooling/fan, some runs heating

Running LED-Off 3S, Blinks 7 times

EA

VRF: Oil valve protection

TBD

Ec

Commercial & VRF: Water flow protection (lack of water flow)

TBD

Ed

System temperature too high

TBD

EE

Memory chip error (U5)

Heating LCD-Off 3S, Blinks 15 times

EF

Outdoor fan motor overload

TBD

EL

Fire alarm

TBD

EP

Shell top high temperature protection

TBD

F0

System refrigerant lack or restriction protection

Cooling LED-Off 3S, Blinks 10 times

F3

Outdoor abmient temperature sensor error

Cooling LED-Off 3S, Blinks 3 times

F8

Incoming water temperature sensor error

Cooling LED-Off 3S, Blinks 8 times

F9

Outgoing water temperature sensor error

Cooling LED-Off 3S, Blinks 9 times

FA

Oil temperature sensor error

TBD

Fd

Suction gas temperature sensor error

TBD

FE

User side water sensor error

TBD

FL

Water tank-middle sensor error

TBD

FP

CO2 checking error

TBD

FU

Shell top temperature sensor error protection

TBD

H1

Heating-Defrosting, or oil return

TBD

H2

Static electric de-dust protection

Heating LED-Off 3S, Blinks 2 times

H3

Compressor over-temperature protection

Heating LED-Off 3S, Blinks 3 times

H4

System abnormal (many different other reasons…)

Heating LED-Off 3S, Blinks 4 times

H5

IPM abnormal / Control M odule Protection

Heating LED-Off 3S, Blinks 5 times

H6

Indoor fan motor-no feedback

Running LED-Off 3S, Blinks 11 times

H7

Comopressor loses steps, not being able to check rotor position

Heating LED-Off 3S, Blinks 7 times

HC

PFC board abnormal / PFC protection

Heating LED-Off 3S, Blinks 6 times

HE

Compressor de-managet protection (rotor locked /doesn't rotate)

Heating LED-Off 3S, Blinks 14 times

L0

Airflow switch error

TBD

L1

Humidity sensor error

TBD

L2

Water level switch error / hot water tank level switch error

TBD

L3

Outdoor DC motor error (L3 for dual -mtor 1, LA for motor 2)

Running LED-Off 3S, Blinks 23 times

L4

Filter clogged

TBD

L5

Circulating water temperature sensor error

TBD

L6

System capacity insufficient

TBD

L7

Water pressure switch protection

TBD

Lc

Starting failure

Heating LED-Off 3S, Blinks 11 times

Ld

Power phase loss/lack

TBD

LE

Compressor locked

Running LED-Off 3S, Blinks 22 times

LF

Compressor over-speed protection

TBD

LH

Indoor ambient temperature too high

TBD

LL

Indoor ambient temperature too low

TBD

LP

Indoor-Outdoor units don't match or power line connection error

Running LED-Off 3S, Blinks 19 times

P0

Driving module resumed

TBD

P5

Driving board checking-compressor current too high

Heating LED-Off 3S, Blinks 15 times

P6

Driving board checking-communication error with indoor board

Heating LED-Off 3S, Blinks 16 times

P7

Radiator loose, or IPM /PFC board sensor abnormal /error

Heating LED-Off 3S, Blinks 18 times

P8

Radiator loose, or IPM  /PFC board too hot

Heating LED-Off 3S, Blinks 19 times

P9

AC contactor protection

TBD

PA

AC current protection (incoming)

TBD

Pc

Current checking-circuit error or current sensor error

TBD

P23 OF 36

P24 OF 36

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

ERROR AND PROTECTION CODE SUMMARY

ERROR AND PROTECTION CODE SUMMARY

Notes

:

1.Some codes are not malfunctions and will not require you to do anything, since the unit will resume normal 
   functions once the unit finishes its designated work such as defrost, oil return...
2.Some other codes denote malfunctions and the unit will not resume normal functions until your technician 
   checks your unit and fixes the problems such as dirty coils, clogged filters, bad control boards...You can 
   have your technician to call 866-833-3138 for help of  technical support and trouble-shoot.

Notes

:

1.Some codes are not malfunctions and will not require you to do anything, since the unit will resume normal 
   functions once the unit finishes its designated work such as defrost, oil return...
2.Some other codes denote malfunctions and the unit will not resume normal functions until your technician 
   checks your unit and fixes the problems such as dirty coils, clogged filters, bad control boards...You can 
   have your technician to call 866-833-3138 for help of  technical support and trouble-shoot.

UNIT MAINTENANCE & 

SER

VICE GUIDE

UNIT MAINTENANCE & 

SER

VICE GUIDE

Содержание WMMS-09K-V2A(57)2

Страница 1: ...nd Heat Pump 09 24k 16 SEER This product is designed and manufactured free from defects in material and workmanship for normal use and maintenance Installation operation maintenance and service shall...

Страница 2: ...trouble free installation proper operation of your products for many years to come YMGI Group POB 1559 O Fallon MO 63366 is the only party who holds the final explanation in authorized writing about...

Страница 3: ...e humidity ranges installation operation maintenance service warranty parts and so on 4 Properly select correct most suitable YMGI product models of units and accessories for your HVAC applications jo...

Страница 4: ...he installation 5 Supply electrical power V Ph Hz measured at wiring terminal block of Indoor unit outdoor unit 7 Wire gauge length and terminal colors between circuit breaker disconnect switch to out...

Страница 5: ...Pump 2 Load calculation must be done carefully and correctly by experienced technician for each room that needs to be conditioned before sizing unit and selecting correct model Not to undersize or ov...

Страница 6: ...nstall them in secured positions PVC line set cover is recommended to protect against rain and sunlight and other potential damage DO NOT blow the cold air directly towards people for prolonged period...

Страница 7: ...3 10 3 10 3 10 26 Evaporator Row fin Gap Inch 2 3 50 2 3 50 2 7 127 2 7 127 27 Evaporator Coil W H x D Inch 24 11 3 5 1 24 11 3 5 1 25 13 15 12 1 512 17x27X1 28 Swing Motor Model MP24BA MP24BA MP28VB...

Страница 8: ...d is discharged so that the indoor room temperature is decreased The cooling capacity will increase or decrease depending on the outdoor air temperature Anti freezing function If the unit is running i...

Страница 9: ...notice then the clock symbol is not flashing Note Under the Dry mode the fan speed isn t adjustable low fan speed is imperative High fan High fan High fan AUTO NAMES AND FUNCTIONS OF WIRELESS REMOTE C...

Страница 10: ...set up by experiments or experience the target temperature quite few degrees higher than what you really want in order to reach a satisfied or more precise indoor comfort This is a common drawback of...

Страница 11: ...ut After 30s later replace them back into the remote control in the correct polarities If the remote control still doesn t work properly then the remote control may need to be replaced Sketch map for...

Страница 12: ...remote control 1 Is the remote control out of battery 2 Is remote control in direct sunlight 3 Is remote control signal blocked 4 Is remote control too far away from indoor unit 5 Is the fuse on indo...

Страница 13: ...protection Heating LED Off 3S Blinks 6 times HE Compressor de managet protection rotor locked doesn t rotate Heating LED Off 3S Blinks 14 times L0 Airflow switch error TBD L1 Humidity sensor error TB...

Страница 14: ...uring gas sensor error Running LED Off 3S Blinks 21 times HP Solar AC solar power input voltage is higher than 180V TBD dA AHU or RT discharge air relative humidity sensor error TBD dE AHU or RT fresh...

Страница 15: ...r Cooling LED Off 3S Blinks 7 times FC Slide door error or air louver mechanism error TBD FE Over load sensor error TBD H8 Water level high overflow protection Heating LED Off 3S Blinks 8 times H9 Ele...

Страница 16: ...0 conducted by a qualified HVAC technician s as detailed in the checklist of the Limited Product Warranty Policy and Limited Product Warranty Registration Card Form along with a properly detailed inst...

Страница 17: ...her details pertaining to your request 4 If YMGI agrees to process your return request a form called Return Goods Authorization RGA along with an assigned RGA will be forwarded to your distributor or...

Страница 18: ...derations All unit removal re installation and shipping cost are the responsibility of the customer YMGI maintains the final authority as to unit replacement Replacement will be made with the same mod...

Страница 19: ...AND INSTALLATION SERVICE MAINTENANCE NOTES Notes Asked for Your Technician for Help Did You Ask YMGI Tech for Help INSTALLATION NOTES Original Installation Company Name Technician Name Phone HVAC Lice...

Отзывы: