Troubleshooting Guide
ID
Problem
Observation
Remedy
001
Gearbox Does Not
Start Up
You hear no noise and shaft
is not turning. You are not
using any driver or frequency
inverter.
Please Check the voltage supply and frequency of your electric
connection. They must be in accordance with the nameplate of
the motor. Observe motor manufacturers start up manual. Still
does not work go to ID 100
002
Gearbox Does Not
Start Up
You hear no noise and shaft
is not turning. You are using
frequency inverter or driver.
Please observe the frequency incerter/driver manual. Chech
the motor by supplying direct voltage to see if the problem is on
your driver/frequency inverter. Still does not work go to ID 001.
003
Gearbox Does Not
Start Up
You hear some noise but both
motor shaft and gearbox shaft
is not turning. You are not
using any driver /frequency in-
verter or braked motor.
Please Check the voltage supply and frequency of your electric
connection. They must be in accordance with the nameplate of
the motor. Observe motor manufacturers start up manual. Still
same problem, the load may be too high for the choosen motor.
Loosen the gearbox from the load/torque.
If it works than the starting torque is insufficient and higher mo-
tor power is needed. For monophaze motors, check the star-
ting up condansator and running condansator as well. If notting
helps go to ID 100
004
Gearbox Does Not
Start Up
You hear some noise but both
motor shaft and gearbox shaft
is not turning. You are using
driver or frequency inverter.
Please observe the frequency inverters or drivers manual. To
see if the problem is on your driver or frequency inverter take
out the driver/frequency inverter and make direct voltage sup-
ply to the motor according the motors nameplate. Still does not
work go to ID 100
005 Gearbox Does Not
Start Up
You hear some noise but both
motor shaft and gearbox shaft
is not turning. You are using
braked motor
Please Check the voltage supply and frequency of your electric
connection. They must be in accordance with the nameplate of
the motor. Observe motor manufacturers start up manual. Be
sure that the brake is working. Observe the brake manufactur-
ers manuel. If brake is supplied from YILMAZ observe this ma-
nuel for correct brake wiring diagram. If still not work supply the
brake with voltage according its nameplate directly. For exam-
ple 198V DC. You will hear a clicking noise explaining that the
brake is opening. If you hear no noise the brake or rectifier is
defect. If you hear the clicking noise the brake is working. You
should this clicking noise by your normal electric connection as
well. By supplying direct supply to the brake you hear the click-
ing noise and at same time you supply the motor with direct
voltage according to its name plate and still same problem, the
load may be too high for the choosen motor. Goto ID 003.
10- Troubleshooting Guide
All the operations bellow must be done by authorized and skilled mechanician/electrician.
Inform YILMAZ REDUKTOR before making any change to the gearbox. Only oil change is allowed to
change without information. Do not make any think if you are not sure what you are doing and contact
YILMAZ. Any change or operation done without the information of YILMAZ REDUKTOR is in your own
risk and responsibility and YILMAZ REDUKTOR does not take any responsibility.
43
Operating Instructions
E Series
Содержание E Series
Страница 1: ...E Series Worm Gearboxes OPERATING INSTRUCTIONS OIECE0302 0422 ...
Страница 47: ...Appendix ...
Страница 50: ...Notlar ...
Страница 51: ...Notlar ...