Maintenance and Inspections
8- Maintenance and Inspections
Under normal ambient and working conditions the gear unit should be checked according
the following intervals. (For definition of normal working conditions refer to the product
catalogue: “Selecting Gearbox” section);
For normal ambient conditions 70
º
C oil bath temperature should be taken as reference
Synthetic oil are using in E.030, E.040, E.050, E.063 E.075, E.080 types and Mineral oil
are using for E.100 and E.125 types.
0
5000
10000
15000
20000
25000
30000
35000
40000
45000
70 80 90 100 110 120 130 140 150 160
O
il c
ha
nge
int
er
va
l [
Hour
s]
Oil bath temperature (Celcius)
Mineral
Synthetic PAO
Synthetic PG
Item to check / Replace
Every 3.000
working hours
or every 6 months
Every 4.000 working
hours
Every 10.000
working hours or
every 3 years
Every 25.000
working hours
Check for oil leakage
x
Check for oil level
x
Check oil leakage from seal
x
Check Rubber buffer
x (Change if necessary)
Check Bearings Noise
x (Change
if necessary)
Change Mineral Oil
x (See Below for
details)
Change Synthetic-PAO Oil
x (See Below for
details)
Change Sealing
x
Change Bearing Grease
x
Change Bearings
x
Check for noise Changes
x