Abrasive material, chemicals, water, positive or negative pressure exceeding 0,2 bar can
affect or damage the sealing lip or output shaft. Inside entering substances from the seals
can cause serious damage to the gear unit.
6.10- Check accessibility to filling, breather and drain plugs;
The filling, breather and drain plugs must be freely accessible for further checking and service.
7- Mechanical Installation
The gear unit can only be installed using the supplied connection points like foot and flange
assembling points.
To install the gear unit without the supplied connection points can cause serious injuries by
loosening or braking the gear unit. Even the gear unit is installed totally correctly according
this manual, be sure that no one will be harmed by accidentally brake downs or loosening.
The mounting plate must be rigid enough not allowing torsions, flat enough to prevent strains
by tightening the bolts and stable enough not allowing vibrations. By using chain drives this
becomes much more important because of the polygon effect on chain drives. According to
your connection elements the maximal permitted radial and axial load of the gear unit must
be in accordance with your application. Check the product catalogue for permitted radial
loads and calculation.
If the output or input shaft is overloaded by radial or axial loads it can cause serious damage
to the gear unit.
Secure the gear unit using 8.8 or higher quality bolts.
Cover all the turning parts from human entering or touching. Turning parts can cause severe
or fatal injuries.
For different kind of basic installations refer to the following illustrations.
Mounting